Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20052A595 + (ML20052A595)
- 05000325/LER-1982-040-03, /03L-0:on 820319,primary Containment Multipoint Temp Recorder 1-CAC-TR-1258 Printed Erratically.Caused by Fouled Electrical Contacts in Recorder Point Select Relay. Contacts Cleaned + (ML20052A597)
- ML20052A598 + (ML20052A598)
- ML20052A599 + (ML20052A599)
- ML20052A600 + (ML20052A600)
- ML20052A601 + (ML20052A601)
- 05000321/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20052A602)
- ML20052A604 + (ML20052A604)
- 05000321/LER-1982-016-03, /03L-0:on 820213,while Performing Routine Surveillance,Sample Pump for Fission Product Monitors Found Inoperable.Caused by Blown Fuse.Fuse Replaced & Sys Returned to Svc + (ML20052A605)
- ML20052A606 + (ML20052A606)
- ML20052A607 + (ML20052A607)
- 05000321/LER-1982-012, Forwards LER 82-012/03L-0 + (ML20052A610)
- 05000338/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20052A612)
- ML20052A614 + (ML20052A614)
- ML20052A615 + (ML20052A615)
- 05000321/LER-1982-012-03, /03L-0:on 820211,HPCI Auxiliary Oil Pump Failed to Perform During Procedure HNP-1-3318,HPCI, Hydraulic Oil Piping Moisture Protection. Cause Not Positively Identified.Suspected Components Replaced + (ML20052A616)
- ML20052A617 + (ML20052A617)
- 05000338/LER-1982-006-03, /03L-0:on 820305,during Mode 1 at 100% Power,A Svc Water Return Header from Units 1 & 2 Charging Pumps & Air Compressors Were Isolated to Repair Pinhole Leak in Return Line.Caused by Aggressive Water Corrosion + (ML20052A618)
- ML20052A620 + (ML20052A620)
- ML20052A621 + (ML20052A621)
- ML20052A624 + (ML20052A624)
- 05000338/LER-1982-008, Forwards LER 82-008/01T-0 + (ML20052A625)
- ML20052A627 + (ML20052A627)
- 05000338/LER-1982-008-01, /01T-0:on 820329,Westinghouse Determined That Six Output Slave Relays Did Not Have Qualified Latching Mechanisms.Caused by Use of Two Different Types of Latches. Latching Mechanisms Will Be Replaced + (ML20052A631)
- ML20052A632 + (ML20052A632)
- 05000321/LER-1982-020, Forwards LER 82-020/03L-0 + (ML20052A633)
- 05000321/LER-1982-020-03, /03L-0:on 820318,oil Leak Found on Reactor Core Isolation Cooling Turbine Outboard Bearing Housing.Caused by Clogged Drain Orifice Inside Bearing Housing.Orifice Cleared + (ML20052A636)
- 05000369/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20052A637)
- PNO-II-82-047, on 820423,licensee Shut Down Plant to Begin Refueling & Inservice Insp Outage.During Outage,Util Will Inspect Steam Generators for Possible Internal Auxiliary Feedwater Header Damage Similar to Davis-Besse + (ML20052A640)
- 05000369/LER-1982-022-03, /03L-0:on 820310,while in Mode 5,procedure Review Revealed Pressurizer 1 Power Operated Relief Valve (PORV) Had Not Been Timed.Procedure Change on 800915 Failed to Include PORV for Time Test.Procedure Changed + (ML20052A643)
- ML20052A644 + (ML20052A644)
- ML20052A647 + (ML20052A647)
- ML20052A649 + (ML20052A649)
- 05000348/LER-1982-013, Forwards LER 82-013/03L-0 + (ML20052A650)
- PNO-II-82-042, on 820417,fire Discovered in Steam Generator Repair Bldg Located Near Unit 1.Both Reactors Not Affected by Fire.Fire Extinguished by Surry County Fire Dept & Plant Fire Brigade.Cause Not Known + (ML20052A655)
- ML20052A656 + (ML20052A656)
- 05000348/LER-1982-013-03, /03L-0:on 820317,containment Atmosphere Activity Monitors R-11 (Particulate Monitor) & R-12 (Gaseous Monitor) Declared Inoperable Due to Failure of Vacuum Pump.Caused by Failed Outboard Pump.Filter & Gasket Replaced + (ML20052A657)
- ML20052A659 + (ML20052A659)
- 05000364/LER-1982-005-03, /03L-0:on 820226,4160-volt B Train Ac Electrical Power Circuit Declared Inoperable When Emergency Bus 2G de-energized.Bus 2G de-energized When Breaker 2-DG15 Opened. Cause Under Investigation + (ML20052A661)
- ML20052A662 + (ML20052A662)
- 05000364/LER-1982-008-03, /03L-0:on 820226,instrumentation Loop Associated w/LI-485 (Steam Generator B Level Indication) Declared Inoperable When Reading Was Out of Tolerance W/Other Channels.Caused by Obstruction in Ref Leg + (ML20052A663)
- ML20052A664 + (ML20052A664)
- ML20052A665 + (ML20052A665)
- 05000364/LER-1982-009-03, /03L-0:on 820228,instrumentation Loop Associated w/FT-474 (Steam Generator a Flow Transmitter) Declared Inoperable.Caused by Leaking Equalizing Valve.Valve Stem Repaired + (ML20052A667)
- ML20052A668 + (ML20052A668)
- ML20052A669 + (ML20052A669)
- ML20052A670 + (ML20052A670)
- 05000364/LER-1982-010-03, /03L-0:on 820226,instrumentation Loop Associated w/LI-474 (Steam Generator a Level Indicator) Declared Inoperable.Caused by Loss of Necessary Level in Ref Leg While Steam Generator Not in Svc.Leg Refilled + (ML20052A671)
- ML20052A673 + (ML20052A673)
- IR 05000305/1981027 + (ML20052A674)
- ML20052A677 + (ML20052A677)