- 05000260/LER-1982-008, Forwards LER 82-008/03L-0 + (ML20049J494)
- ML20049J496 + (ML20049J496)
- 05000280/LER-1982-013-03, /03L-0:on 820126,dropped Control Rod Resulted in Quadrant to Average Power Tilt of Greater than 2%.Caused by Corroded Conductors in Power Supply Due to Break in Cable Admitting Moisture.Cable Repaired & Control Rod Realigned + (ML20049J497)
- 05000260/LER-1982-008-03, /03L-0:on 820127,after Calibr,Rod Block Monitor Channel B Failed to Pass Functional Test of SI 4.2.C-2. Caused by Electronic IC Failure Possibly Due to Voltage Spike During Calibr.Ge 136B1333G1 Gain Change Card Replaced + (ML20049J498)
- ML20049J499 + (ML20049J499)
- 05000369/LER-1982-012, Forwards LER 82-012/03L-0.Detailed Event Analysis Encl + (ML20049J500)
- 05000261/LER-1982-033, Forwards LER 82-033/01X-1 + (ML20049J502)
- 05000324/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20049J504)
- 05000324/LER-1982-026-03, /03L-0:on 820202,low Level Switch, 2-B21-LIS-NO31B-2,which Provides One of Signals Required to Initiate Automatic Depressurization Sys Failed.Cause Could Not Be Determined.Switch Replaced + (ML20049J506)
- 05000369/LER-1982-012-03, /03L-0:on 820119,routine QA Audit of Fire Protection Sys Test Found Three Valves Marked Not Accessible & Had Not Been Checked.Caused by Personnel Error.Periodic Test Performed & Valves Found in Correct Position + (ML20049J508)
- 05000369/LER-1982-013, Forwards LER 82-013/03L-0.Detailed Event Analysis Encl + (ML20049J509)
- ML20049J511 + (ML20049J511)
- ML20049J512 + (ML20049J512)
- 05000369/LER-1982-014, Forwards LER 82-014/03L-0 + (ML20049J513)
- 05000369/LER-1982-013-03, /03L-0:on 820126,two Upper Head Injection Train a Accumulator Tank Level Switches Miscalibr,Rendering Isolation Valves Inoperable.Caused by Faulty Data Programmed Into Computer Memory.Program Corrected + (ML20049J515)
- ML20049J516 + (ML20049J516)
- ML20049J517 + (ML20049J517)
- 05000281/LER-1982-013, Forwards LER 82-013/03L-0 + (ML20049J518)
- 05000287/LER-1982-001, Forwards LER 82-001/03L-0.Detailed Event Analysis Encl + (ML20049J520)
- ML20049J522 + (ML20049J522)
- 05000287/LER-1982-001-03, /03L-0:on 820128,channel B Borated Water Storage Tank Level Indication Declared Inoperable Due to Erratic Indication.Caused by Dirt & Oil in Level Indicator Booster Relay & High Thermostat Settings on Sys Heat Trace + (ML20049J523)
- 05000369/LER-1982-014-03, /03L-0:on 820128,process Monitoring Sys Containment Gas Monitor EMF-39(L) Declared Inoperable Due to Scale Low Indication & Loss of Indication.Caused by Failure of Quality Bnn Connector.Sys Repaired + (ML20049J524)
- 05000281/LER-1982-013-03, /03L-0:on 820124,radioiodine Sample Taken 6-h & 28 Minutes Following Thermal Power Increase,Exceeded Tech Spec Time Limit.Caused by Delayed Oncoming Shift Chemists Due to Traffic Problems + (ML20049J525)
- 05000328/LER-1982-021, Forwards LER 82-021/01T-0 + (ML20049J526)
- ML20049J528 + (ML20049J528)
- 05000328/LER-1982-021-01, /01T-0:on 820217,during Startup,Shutdown Rods in Shutdown Bank a Exceeded Plus/Minus 12 Steps of Actual Position on Indicators.Caused by Misinterpretation of Limiting Condition for Operation 3.1.3.3.Rods Recalibr + (ML20049J529)
- 05000338/LER-1982-005, Forwards LER 82-005/03L-0 + (ML20049J530)
- ML20049J532 + (ML20049J532)
- ML20049J533 + (ML20049J533)
- 05000338/LER-1982-005-03, /03L-0:on 820211,w/unit in Mode 1,RCS Unidentified Leakage Was Determined in Excess of Tech Specs.Caused by Packing Leak on 1-RC-129 Level Instrument Isolation Valve. Valves 1-RC-129 & 1-RC-130 Closed + (ML20049J534)
- 05000280/LER-1982-017-03, /03L-0:on 820131,PR-27 Revealed Ampere Readings for Heat Tracing Panels 8 & 9,circuits 24A & C Below Acceptance Criteria.Caused by Loss of Heat Tracing Due to Excessive Heat.Tracing Replaced.Design Change Initiated + (ML20049J535)
- 05000280/LER-1982-016-03, /03L-0:on 820131,loss of Boric Acid Flow to Blender Observed While Attempting Blend to Vol Control Tank. Caused by Loss of Heat Tracing & Damaged Insulation Upstream of Flow Transmitter.Tracing Replaced + (ML20049J536)
- ML20049J537 + (ML20049J537)
- ML20049J539 + (ML20049J539)
- ML20049J540 + (ML20049J540)
- ML20049J541 + (ML20049J541)
- ML20049J543 + (ML20049J543)
- ML20049J544 + (ML20049J544)
- ML20049J545 + (ML20049J545)
- ML20049J547 + (ML20049J547)
- ML20049J548 + (ML20049J548)
- ML20049J549 + (ML20049J549)
- ML20049J550 + (ML20049J550)
- ML20049J551 + (ML20049J551)
- ML20049J552 + (ML20049J552)
- ML20049J553 + (ML20049J553)
- ML20049J554 + (ML20049J554)
- ML20049J555 + (ML20049J555)
- ML20049J556 + (ML20049J556)
- ML20049J557 + (ML20049J557)
- ML20049J558 + (ML20049J558)