Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20044D478 + (ML20044D478)
- ML20044D479 + (ML20044D479)
- ML20044D483 + (ML20044D483)
- 05000321/LER-1993-004, Forwards LER 93-004-00 Re Fuse Actuation Which Caused Unplanned Automatic ESF Sys Actuation & Interruption of Shutdown Cooling + (ML20044D484)
- 05000321/LER-1993-004-01, :on 930414,unplanned ESF Sys Actuation Occurred When LPCI Valve Automatically Reclosed.Caused by Inadvertent Grounding of Logic Circuit,Resulting in Blown Fuse.Fuse Replaced & Operating Order Issued + (ML20044D488)
- ET-NRC-93-3883, Forwards Nonproprietary Repts WCAP-13283,Rev 1 & WCAP-13278, Rev 1 & Proprietary Repts WCAP-13234,Rev 1 & WCAP-13277,Rev 1 Re AP600 Testing Program. Proprietary Portion of Document Sent to Westinghouse + (ML20044D505)
- ML20044D507 + (ML20044D507)
- ET-NRC-93-3886, Forwards Westinghouse Responses to NRC Requests for Addl Info on AP600 from 930126,0218,0312 & 0413 Ltrs.Westinghouse Responses to Remainder of Requests for Addl Info Contained in Will Be Provided Prior to 930529 + (ML20044D512)
- ML20044D514 + (ML20044D514)
- 05000374/LER-1992-007-01, :on 920613,high Radiation Spike Received from CR Ventilation Process Radiation Monitor,Initiating Emergency Makeup Train B.Caused by Normal Variations in Radiation Readings.Spike Modified + (ML20044D516)
- ML20044D518 + (ML20044D518)
- ML20044D520 + (ML20044D520)
- ML20044D522 + (ML20044D522)
- 05000334/LER-1993-006-01, :on 930415,two Operators Entered Posted Area W/O Radiation Monitoring Device & Entered Locked High Radiation Area & Left Barrier Open.Caused by Personnel Error in Judgement.Operators Counseled + (ML20044D525)
- ML20044D526 + (ML20044D526)
- ML20044D529 + (ML20044D529)
- ML20044D532 + (ML20044D532)
- 05000298/LER-1993-012, :on 930414,violation of Primary Containment Integrity Occurred.Caused by Personnel Error.Procedure Change Being Made to Eliminate Test Return Line Venting When Primary Containment Integrity Required + (ML20044D534)
- ML20044D535 + (ML20044D535)
- 05000263/LER-1990-001-01, :on 900313,design Deficiencies Noted in Emergency Filter Train Sys.On 930315,determined That Train B of CR Emergency Filtration Sys Could Not Provide Adequate Flow.Alternate Measuring Sys Method Implemented + (ML20044D536)
- 05000263/LER-1989-040-01, :on 891219,secondary Containment Failed to Meet Operability Requirements During Special Test.Caused by Design Deficiencies.Operating Procedures Revised & Administrative Hold Placed on One Sys Component + (ML20044D538)
- RBG-38-498, Application for Amend to License NPF-47,changing Attachment 3 to License NPF-47,Amend 15, Tdi Diesel Engines Requirements. Group Cross Ref Table Between NUREG-1216 & Current River Bend Status Encl + (ML20044D539)
- ML20044D540 + (ML20044D540)
- ML20044D543 + (ML20044D543)
- ML20044D549 + (ML20044D549)
- ML20044D550 + (ML20044D550)
- 05000373/LER-1993-010-02, :on 930414,DG Cooling Water Pump Automatically Tripped on Magnetic Overload.Caused by Inexperienced Trainee in Operation of Control Lever.Lesson Plans & Training Programs for Operators to Be Reviewed + (ML20044D557)
- ML20044D558 + (ML20044D558)
- ML20044D562 + (ML20044D562)
- 05000309/LER-1993-008, :on 930415,ECCS Valves Found Unlocked.Caused by Oversight in Procedure Controls Due to Misunderstanding of Lube Water Supply Requirements for Svc Water Pump Operability.Controlling Procedures Revised + (ML20044D564)
- ML20044D566 + (ML20044D566)
- ML20044D568 + (ML20044D568)
- ML20044D569 + (ML20044D569)
- 05000339/LER-1993-002-02, :on 930416,automatic Reactor Trip Initiated from Turbine Trip Due to Over Excitation of Main Generator. Emergency Procedure 2-E-0 Entered & Individuals Involved in Event Received Remediated Training + (ML20044D571)
- ML20044D573 + (ML20044D573)
- ML20044D575 + (ML20044D575)
- ML20044D580 + (ML20044D580)
- ML20044D583 + (ML20044D583)
- ML20044D584 + (ML20044D584)
- ML20044D585 + (ML20044D585)
- ML20044D588 + (ML20044D588)
- ML20044D589 + (ML20044D589)
- 05000321/LER-1993-005, Forwards LER 93-005-00 Re Blown Fuse Resulting in Unplanned Actuations of ESF + (ML20044D590)
- 05000321/LER-1993-005-01, :on 930414,fuse 1D11-A-f14B Blew,Resulting in Initiation of Train B of Both Standby Treatment Sys Units & Isolation of Damper B of Both Secondary Containments.Blown Fuse & Several Relays in Logic Replaced + (ML20044D593)
- ML20044D597 + (ML20044D597)
- ML20044D601 + (ML20044D601)
- ML20044D602 + (ML20044D602)
- ML20044D606 + (ML20044D606)
- ML20044D607 + (ML20044D607)
- ML20044D609 + (ML20044D609)
- ML20044D613 + (ML20044D613)