Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20042B212 + (ML20042B212)
- ML20042B215 + (ML20042B215)
- ML20042B216 + (ML20042B216)
- ML20042B217 + (ML20042B217)
- ML20042B220 + (ML20042B220)
- 05000346/LER-1981-068, Forwards LER 81-068/03L-1 + (ML20042B221)
- ML20042B223 + (ML20042B223)
- ML20042B226 + (ML20042B226)
- ML20042B227 + (ML20042B227)
- 05000346/LER-1981-068-03, /03L-1:on 811024,QC Inspector Found Improperly Sealed Core Drill in Fire Wall in Electrical Penetration Room 2.Caused by Procedural Inadequacy.Hole Stuffed W/ Kaowool & Filled Permanently W/Bisco + (ML20042B229)
- ML20042B230 + (ML20042B230)
- ML20042B231 + (ML20042B231)
- 05000271/LER-1982-004, Forwards LER 82-004/03L-0 + (ML20042B232)
- ML20042B234 + (ML20042B234)
- ML20042B235 + (ML20042B235)
- 05000271/LER-1982-004-03, /03L-0:on 820216,discovered That Continuous Environ Air Sample Not Obtainable at Station AT1.4 Per Tech Spec.Caused by Solder Lug of Std 125V-8A Power Toggle Switch Parting at 90 Degree Bend.Faulty Switch Replaced + (ML20042B236)
- ML20042B237 + (ML20042B237)
- ML20042B238 + (ML20042B238)
- ML20042B239 + (ML20042B239)
- ML20042B240 + (ML20042B240)
- ML20042B241 + (ML20042B241)
- ML20042B243 + (ML20042B243)
- ML20042B245 + (ML20042B245)
- ML20042B246 + (ML20042B246)
- ML20042B247 + (ML20042B247)
- ML20042B248 + (ML20042B248)
- ML20042B249 + (ML20042B249)
- ML20042B250 + (ML20042B250)
- IR 05000261/1982006 + (ML20042B251)
- ML20042B252 + (ML20042B252)
- ML20042B253 + (ML20042B253)
- ML20042B254 + (ML20042B254)
- ML20042B255 + (ML20042B255)
- 05000331/LER-1982-017, Forwards LER 82-017/01T-0 + (ML20042B256)
- ML20042B258 + (ML20042B258)
- 05000331/LER-1982-017-01, /01T-0:on 820307,during Surveillance Testing, Standby Filter Unit a for Control Bldg Ventilation Sys Discovered to Have Low Halogenated Hydrocarbon Removal Efficiency.Caused by Moisture in Charcoal Adsorber Bank + (ML20042B259)
- ML20042B260 + (ML20042B260)
- ML20042B262 + (ML20042B262)
- ML20042B265 + (ML20042B265)
- ML20042B267 + (ML20042B267)
- IR 05000416/1982006 + (ML20042B268)
- ML20042B269 + (ML20042B269)
- ML20042B274 + (ML20042B274)
- ML20042B276 + (ML20042B276)
- ML20042B278 + (ML20042B278)
- 05000317/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20042B281)
- ML20042B284 + (ML20042B284)
- IR 05000518/1982001 + (ML20042B285)
- ML20042B286 + (ML20042B286)
- ML20042B287 + (ML20042B287)
- 05000317/LER-1982-006-03, /03L-0:on 820215,containment Air Cooler Fan 13 Could Not Be Stopped or Shifted to Low Speed from Control Room.Cause Not Determined & No Maint Action Performed.Fan Returned to Svc + (ML20042B288)