- 05000311/LER-1981-131, Forwards LER 81-131/03L-0.Detailed Event Analysis Encl + (ML20040C676)
- ML20040C679 + (ML20040C679)
- 05000338/LER-1981-089-03, /03L-0:on 811217,during 99% Power,Turbine Driven Auxiliary Feedwater Pump Removed from Svc for Insp of Three Upsteam Check Valves.One Valve Found Missing Disc Nut,Washer & Retaining Pin.Parts Replaced on All Three Valves + (ML20040C680)
- 05000335/LER-1981-055, Forwards LER 81-055/03L-0 + (ML20040C681)
- 05000320/LER-1981-037, Forwards LER 81-037/03L-0 + (ML20040C683)
- 05000311/LER-1981-131-03, /03L-0:on 811228,low Reading Noticed on 24 Reactor Coolant Loop Flow Channel 2.Channel Declared Inoperable. Caused by Failure of Flow Transmitter.Flow Transmitter Replaced & Calibr Satisfactorily + (ML20040C685)
- PNO-II-82-012, on 820119,turbine & Reactor Tripped Due to High Water Level in Steam Generator 2 During Automatic Feed Control Sys Adjustment.Feedwater Isolation Resulted in Low Water Level in Steam Generator 1 Actuating Trip + (ML20040C686)
- ML20040C687 + (ML20040C687)
- 05000271/LER-1981-036, Forwards LER 81-036/03L-0 + (ML20040C688)
- 05000320/LER-1981-037-03, /03L-0:on 811217,high Motor Bearing Temp Alarm Annunciated in Control Room for Nuclear Svc River Water Pump NR-P-1B.Caused by Failure of Lower Motor Bearing.Motor Replaced.Investigation Continuing + (ML20040C690)
- ML20040C691 + (ML20040C691)
- ML20040C692 + (ML20040C692)
- 05000335/LER-1981-055-03, /03L-0:on 811219,during Normal Reactor Startup, Surveillance Requirement to Manually Trip Rx Trip Breakers Not Performed Per Tech Spec Limits.Caused by Personnel Error + (ML20040C693)
- ML20040C694 + (ML20040C694)
- 05000309/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040C695)
- 05000271/LER-1981-036-03, /03L-0:on 811217,containment Isolation Valve CU-15 Failed to Seat Satisfactorily Per Tech Spec 4.7.D.1 During Quarterly Surveillance Testing.Caused by Failure of Closing Torque Switch.Torque Switch Will Be Replaced Next Shut + (ML20040C697)
- ML20040C698 + (ML20040C698)
- 05000321/LER-1981-143, Forwards LER 81-143/03L-0 + (ML20040C699)
- ML20040C701 + (ML20040C701)
- ML20040C702 + (ML20040C702)
- ML20040C703 + (ML20040C703)
- 05000309/LER-1982-001-03, /03L-0:on 811223,cracks Found in 0.5-inch Lines During Maint on Leaking Ball Valve.Caused by Frozen Lines Due to Failure of Heat Tracing on Recirculation Flow Transmitter Lines.Valve Parts & Heat Tracing Repaired + (ML20040C704)
- 05000321/LER-1981-143-03, /03L-0:on 811230,LPCI Reactor Level Switch, 1B21-N031A,contact on Switch 2,failed to Actuate at Tech Spec Levels.Caused by Bad Contact on Switch 2.Switch Replaced,Recalibr & Returned to Svc + (ML20040C705)
- ML20040C706 + (ML20040C706)
- ML20040C708 + (ML20040C708)
- ML20040C709 + (ML20040C709)
- 05000327/LER-1981-157, Forwards LER 81-157/03L-0 + (ML20040C710)
- 05000278/LER-1981-021-03, /03L-0:on 811211,D Core Spray Pump Failed to Start During Surveillance Test Due to Failure of Pump Breaker to Close.Cause Not Determined.Failed Breaker Replaced & Checked Daily for 2 Wks to Verify Core Spray Sys Operability + (ML20040C712)
- ML20040C713 + (ML20040C713)
- 05000366/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040C714)
- ML20040C716 + (ML20040C716)
- ML20040C717 + (ML20040C717)
- ML20040C718 + (ML20040C718)
- ML20040C719 + (ML20040C719)
- 05000366/LER-1982-001-03, /03L-0:on 820101,low Pressure Alarm Received on Control Rod Drive Line Hydraulic Control Unit 26-47 Due to Switch Being Out of Tolerance.Caused by Setpoint Drift. Switch Recalibr & Returned to Svc + (ML20040C720)
- ML20040C721 + (ML20040C721)
- 05000327/LER-1981-157-03, /03L-0:on 811222,pressurizer Level Transmitter 1-LT-68-335 Declared Inoperable Due to Failure to Meet Channel Check Requirements.Caused by Accumulation of Gases in Condensate Reservoirs & Sensor Bellows.Gases Vented + (ML20040C722)
- IR 05000320/1981022 + (ML20040C725)
- 05000324/LER-1981-137, Forwards LER 81-137/03L-0 + (ML20040C726)
- ML20040C728 + (ML20040C728)
- 05000327/LER-1981-151, Forwards LER 81-151/03L-0 + (ML20040C732)
- 05000272/LER-1981-121-03, /03L-0:on 811228,svc Water Leak Discovered in Containment Fan Coil Spool Piece Between Valves 125W57 & 125W58 in 78-ft Evaluation North Penetration Area.Cause Not Stated.Spool Will Be Changed to Stainless Steel + (ML20040C734)
- 05000324/LER-1981-137-03, /03L-0:on 811218,during Scram Recovery,Reactor Core Isolation Cooling Sys Turbine Tripped & Trip/Throttle Valve 2-E51-MOV-V8 Failed to Reset.Caused by Electrical Shorting to Ground of MOV-V8 Solenoid Control Lead + (ML20040C735)
- 05000260/LER-1981-065, Forwards LER 81-065/03L-0 + (ML20040C736)
- 05000327/LER-1981-151-03, /03L-0:on 811221,w/unit in Mode 1,one Containment Sump Level Transmitter Declared Inoperable Due to Erratic High Readings.Caused by Instrument Drift.Instrument Recalibr + (ML20040C738)
- ML20040C739 + (ML20040C739)
- 05000335/LER-1981-057, Forwards LER 81-057/03L-0 + (ML20040C741)
- 05000366/LER-1981-119, Forwards LER 81-119/03L-0 + (ML20040C743)
- ML20040C745 + (ML20040C745)
- 05000366/LER-1981-126, Forwards LER 81-126/03L-0 + (ML20040C746)
- ML20040C748 + (ML20040C748)