- ML20039D909 + (ML20039D909)
- 05000277/LER-1981-046-01, /01T-0:on 811205,trip Setpoints Raised Above Tech Spec Range to Aid Restart of Ventilation Sys.Caused by High Temp Alarms & Isolation Channel Trip After Loss of Reactor Bldg Ventilation.Tech Spec Change Pending + (ML20039D911)
- 05000247/LER-1981-029-03, /03L-0:on 811119,during Test Run of Safety Injection Pump,Motor Emitted Smoke & Did Not Turn.Caused by Frozen Shaft Bushings on Pump Rotating Elements.Pump Replaced + (ML20039D912)
- ML20039D913 + (ML20039D913)
- ML20039D916 + (ML20039D916)
- 05000272/LER-1981-115-03, /03L-0:on 811120,feed Flow Greater That Steam Flow Alarm Received & Steam Generator Level Found Dropping. Caused by Failure of Steam Generator Steam Flow Channel 2 Due to Transmitter Failure + (ML20039D918)
- 05000334/LER-1981-102, Forwards LER 81-102/03L-0 + (ML20039D919)
- ML20039D922 + (ML20039D922)
- ML20039D926 + (ML20039D926)
- ML20039D930 + (ML20039D930)
- ML20039D932 + (ML20039D932)
- ML20039D934 + (ML20039D934)
- 05000219/LER-1981-058, Forwards LER 81-058/03L-0.Detailed Event Analysis Encl + (ML20039D935)
- 05000336/LER-1981-039, Forwards LER 81-039/03L-0 + (ML20039D938)
- 05000219/LER-1981-058-03, /03L-0:on 811111,containment Spray Sys High Drywell Pressure Indicating Switches Found to Trip at Values Greater than Tech Spec Limits.Caused by Instrument Repeatability + (ML20039D940)
- PNO-III-81-120, on 811223,HPCI Sys Inoperative Following Automatic Fire Sprinkler Activation in HPCI Room.Cause of Failure Cannot Be Determined Until Drywell Entry Made. Similar Event Occurred 811129 (PNO-III-81-105) + (ML20039D941)
- ML20039D943 + (ML20039D943)
- 05000369/LER-1981-180, Forwards LER 81-180/03L-0.Detailed Event Analysis Encl + (ML20039D945)
- 05000369/LER-1981-180-03, /03L-0:on 811112,containment Temp Exceeded 120 F Limit & Two Temp Sensors Indicated as High as 140 F.Caused by Mislabeling Containment Ventilation Return Isolation Valve 1RN153.Valve Reopened & Relabeled + (ML20039D947)
- ML20039D948 + (ML20039D948)
- ML20039D949 + (ML20039D949)
- ML20039D951 + (ML20039D951)
- ML20039D952 + (ML20039D952)
- 05000270/LER-1981-018, Forwards LER 81-018/01T-0.Detailed Event Analysis Encl + (ML20039D953)
- 05000336/LER-1981-039-03, /03L-0:on 811203,Channel B of Reactor Protective Sys Became Erratic Due to Failure of Tc Inputs.Caused by Moisture from Steam Leak Accumulating on RTD Leads in Terminal Box That Had Been Left Open + (ML20039D955)
- ML20039D956 + (ML20039D956)
- 05000270/LER-1981-018-01, /01T-0:on 811123,component Cooling Water Discharge Valve to Keowee Tailrace Inadvertently Opened & Failed Open. Caused by Personnel Error & Failure of Valve CCW-8.Valve Manually Closed.Procedures Will Be Revised + (ML20039D958)
- 05000255/LER-1981-049, Forwards LER 81-049/03L-0 + (ML20039D959)
- ML20039D961 + (ML20039D961)
- ML20039D962 + (ML20039D962)
- ML20039D963 + (ML20039D963)
- ML20039D964 + (ML20039D964)
- 05000255/LER-1981-049-03, /03L-0:on 811211,pressure Control Sys (PCS) Charging Letdown Mismatch of 32 Gpm Found.Caused by PCS Leakage Due to Improperly Installed Gasket in Control Rod Drive Mechanism Seal Housing + (ML20039D965)
- ML20039D966 + (ML20039D966)
- 05000245/LER-1981-037-01, /01P-0:on 811214,is Cancelled + (ML20039D968)
- ML20039D969 + (ML20039D969)
- ML20039D970 + (ML20039D970)
- ML20039D973 + (ML20039D973)
- ML20039D974 + (ML20039D974)
- IR 05000546/1981021 + (ML20039D975)
- ML20039D977 + (ML20039D977)
- ML20039D978 + (ML20039D978)
- ML20039D981 + (ML20039D981)
- ML20039D983 + (ML20039D983)
- ML20039D985 + (ML20039D985)
- ML20039D986 + (ML20039D986)
- ML20039D988 + (ML20039D988)
- ML20039D989 + (ML20039D989)
- ML20039D991 + (ML20039D991)
- ML20039D993 + (ML20039D993)
- ML20039D994 + (ML20039D994)