List of results
- ML20010E171 + (ML20010E171)
- ML20010E172 + (ML20010E172)
- ML20010E173 + (ML20010E173)
- 05000155/LER-1981-016-01, /01T-0:on 810813,discovered That Actions to Mitigate Potential for Pressurization of Reactor Containment from Instrument & Svc Air Sources Not Incorporated Into Plant Procedures + (ML20010E174)
- ML20010E175 + (ML20010E175)
- ML20010E176 + (ML20010E176)
- ML20010E178 + (ML20010E178)
- ML20010E179 + (ML20010E179)
- ML20010E180 + (ML20010E180)
- ML20010E182 + (ML20010E182)
- ML20010E184 + (ML20010E184)
- ML20010E185 + (ML20010E185)
- 05000311/LER-1981-077, Forwards LER 81-077/03L-0.Detailed Event Analysis Encl + (ML20010E187)
- ML20010E188 + (ML20010E188)
- ML20010E189 + (ML20010E189)
- 05000311/LER-1981-077-03, /03L-0:on 810729,Number 22 Reactor Coolant Flow Channel 2 Noted Reading Higher than Other Two Channels. Caused by Failure of Flow Transmitter 2FT-425.Transmitter Replaced & Returned to Svc + (ML20010E190)
- ML20010E191 + (ML20010E191)
- 05000346/LER-1981-040, Forwards LER 81-040/01X-1 + (ML20010E192)
- ML20010E193 + (ML20010E193)
- ML20010E194 + (ML20010E194)
- 05000346/LER-1981-040-01, /01X-1:on 810514,fuel Assembly Holddown Spring Discovered Broken.Caused by Stress Corrosion Cracking. All 177 Springs Replaced W/Improved Matl + (ML20010E195)
- 05000346/LER-1981-044, Forwards LER 81-044/03L-0 + (ML20010E196)
- ML20010E197 + (ML20010E197)
- ML20010E198 + (ML20010E198)
- 05000346/LER-1981-044-03, /03L-0:on 810727,decay Heat Pump 1-1 Would Not Start.Caused by Improperly Handled Fuse Cartridge Causing Cartridge plug-in to Be bent.Plug-in Straightened to Proper Alignment + (ML20010E199)
- ML20010E200 + (ML20010E200)
- ML20010E201 + (ML20010E201)
- ML20010E202 + (ML20010E202)
- ML20010E203 + (ML20010E203)
- ML20010E204 + (ML20010E204)
- ML20010E205 + (ML20010E205)
- ML20010E206 + (ML20010E206)
- ML20010E207 + (ML20010E207)
- GO2-81-025, Final Deficiency Rept Re Incorrect Class Designation of Control Room Balance of Plant Panels,Initially Reported 810520.Investigation Has Determined Condition Not Reportable Under 10CFR50.55(e) + (ML20010E208)
- ML20010E209 + (ML20010E209)
- ML20010E211 + (ML20010E211)
- ML20010E212 + (ML20010E212)
- ML20010E213 + (ML20010E213)
- ML20010E214 + (ML20010E214)
- ML20010E216 + (ML20010E216)
- ML20010E217 + (ML20010E217)
- ML20010E218 + (ML20010E218)
- ML20010E219 + (ML20010E219)
- ML20010E220 + (ML20010E220)
- ML20010E221 + (ML20010E221)
- ML20010E222 + (ML20010E222)
- ML20010E223 + (ML20010E223)
- PNO-I-81-097, on 810827,tube Failure in Shutdown Cooling Sys Heat Exchanger C Resulted in Leakage of Reactor Coolant Into Reactor Bldg Closed Cooling Water Sys.Cause Undetermined.Plant Startup Delayed Pending Investigation + (ML20010E224)
- ML20010E226 + (ML20010E226)
- 05000277/LER-1981-038-01, /01T-0:on 810812,cable Designation & Routing Errors Discovered on 4-kV Emergency Bus Breaker Control Cable Schemes,Resulting in Separation Deficiencies on Various Control Switches & Relays.Caused by Design Error + (ML20010E227)
- ML20010E228 + (ML20010E228)