- ML20009F673 + (ML20009F673)
- ML20009F674 + (ML20009F674)
- ML20009F675 + (ML20009F675)
- 05000366/LER-1981-065-03, /03L-0:on 810626,hydrogen-oxygen Analyzer Found Inoperable.Caused by Partially Clogged Gas Flow Regulators. Gas Flow Regulators Cleaned & Readjusted.Analyzer Recalibr + (ML20009F676)
- 05000302/LER-1981-039-03, /03L-0:on 810630,control Rod Units 1 & 2 Rendered Inoperable During Maint on House Svcs Transformer.Caused by Personnel Shorting 4,160-volt Bus Supplying Startup Transformer While Checking Energized Sections + (ML20009F678)
- ML20009F680 + (ML20009F680)
- 05000369/LER-1981-072, Forwards LER 81-072/03L-0.Detailed Event Analysis Encl + (ML20009F681)
- ML20009F683 + (ML20009F683)
- 05000366/LER-1981-061, Forwards LER 81-061/03L-0 + (ML20009F684)
- ML20009F685 + (ML20009F685)
- ML20009F686 + (ML20009F686)
- 05000327/LER-1981-065, Forwards LER 81-065/03L-0 + (ML20009F687)
- ML20009F688 + (ML20009F688)
- 05000369/LER-1981-072-03, /03L-0:on 810427,RHR Sys Discovered Isolated from RCS During Mod of Train a Solid State Protection Sys to Include Reactor on Turbine Trip.Caused by de-energized Relay in Logic,Closing Isolation Valve + (ML20009F689)
- 05000369/LER-1981-076, Forwards LER 81-076/03L-0.Detailed Event Analysis Encl + (ML20009F691)
- ML20009F694 + (ML20009F694)
- ML20009F695 + (ML20009F695)
- ML20009F697 + (ML20009F697)
- 05000369/LER-1981-076-03, /03L-0:on 810502,alarm Annunciated for Noble Gas Activity monitor,EMF-33,indicating Loss of Sample Flow During Initial Fuel Loading.Caused by Bolts Insufficiently Tightened to Secure Seals During Monitor Maint + (ML20009F698)
- ML20009F700 + (ML20009F700)
- 05000327/LER-1981-065-03, /03L-0:on 810603,turbine Sump Discharge Monitor O-RM-90-212 Declared Inoperable.Caused by Broken Pump/Motor Coupling.Coupling Replaced & Monitor Returned to Svc + (ML20009F701)
- 05000366/LER-1981-061-03, /03L-0:on 810624,hi-lo Flow Alarm Received for Reactor Bldg Vent Radiation Monitor Sys.Caused by Tripping of Sample Pumps a & B Due to Overload Protection Tripping. Vanes in Pump a Replaced.Pump B Overload Reset + (ML20009F703)
- 05000339/LER-1981-047, Forwards LER 81-047/03L-0 + (ML20009F705)
- ML20009F706 + (ML20009F706)
- ML20009F707 + (ML20009F707)
- 05000339/LER-1981-047-03, /03L-0:on 810609,solid State Protection Sys Train B Stop Valve Generator Trip Logic Failed to Meet Acceptance Criteria.Caused by Faulty Universal Card A404. Card Replaced & Logic Channel Returned to Svc + (ML20009F708)
- 05000280/LER-1981-015, Forwards LER 81-015/03L-0,updated LER 81-035/03X-1 & Corrected LER 81-036/03L-0 + (ML20009F710)
- ML20009F711 + (ML20009F711)
- 05000366/LER-1981-067, Forwards LER 81-067/03L-0 + (ML20009F712)
- ML20009F713 + (ML20009F713)
- 05000280/LER-1981-015-03, /03L-0:on 810603,spent Fuel Pit Overflowed Into New Fuel Handling Area & Outside to Storm Drain.Caused by Leaking Diaphragm Valve & Defeated High Level Alarm Annunciator.Valve Repaired + (ML20009F714)
- ML20009F715 + (ML20009F715)
- ML20009F716 + (ML20009F716)
- 05000280/LER-1981-035-03, Fuel Oil Transfer Pump 1B Suction Valve 1-EE-14 Found Closed.Caused by Personnel Error.Valve Opened + (ML20009F717)
- 05000369/LER-1981-083, Forwards LER 81-083/01T-0.Detailed Event Analysis Encl + (ML20009F718)
- ML20009F719 + (ML20009F719)
- 05000369/LER-1981-070, Forwards LER 81-070/03L-0.Detailed Event Analysis Encl + (ML20009F720)
- ML20009F721 + (ML20009F721)
- 05000366/LER-1981-067-03, /03L-0:on 810626,site Notified That Procedures Used for Checking Positions of Psw Valves Serving safety- Related Equipment Were Inadequate.Caused by Erroneous Determination That HNP2-3182 Confirms Valve Position + (ML20009F722)
- 05000280/LER-1981-036, Corrected LER 81-036/03L-0,changing Sequential Date of LER 81-033/03L-0.On 810528,sample of Emergency Diesel Generator Fuel Oil Storage Tanks Revealed Water in Tank 1-EE-TK-2A + (ML20009F723)
- 05000369/LER-1981-070-03, /03L-0:on 810426,while in Mode 3,initial Fuel Loading Cold Leg Injection Accumulator C High Level Alarm Received in Control Room.Caused by Leaking Discharge Check Valves.Leaking Valve Repaired + (ML20009F724)
- 05000369/LER-1981-083-01, /01T-0:on 810522,while in Mode 5 Initial Fuel Loading Radiation Monitor EMF-49 Was Inoperable During Liquid Waste Release.Release Was Terminated & Inadvertantly Restarted.Caused by Misinterpretation of Directions + (ML20009F725)
- ML20009F726 + (ML20009F726)
- 05000369/LER-1981-071, Forwards LER 81-071/03L-0.Detailed Event Analysis Encl + (ML20009F727)
- ML20009F728 + (ML20009F728)
- ML20009F729 + (ML20009F729)
- ML20009F730 + (ML20009F730)
- 05000369/LER-1981-085, Forwards LER 81-085/03L-0.Detailed Event Analysis Encl + (ML20009F731)
- ML20009F732 + (ML20009F732)
- 05000369/LER-1981-071-03, /03L-0:on 810426,while in Mode 4,initial Fuel Loading,Only Boration Flow Path Extended from Refueling Water Storage Tank to RCS Through Centrifugal Charging Pump 1B.Caused by Fully Open Valve.Valve Repositioned + (ML20009F734)
- 05000366/LER-1981-054, Forwards LER 81-054/03L-0 + (ML20009F735)