Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20004D676 + (ML20004D676)
- ML20004D678 + (ML20004D678)
- 05000260/LER-1981-022, Forwards LER 81-022/03L-0 + (ML20004D679)
- ML20004D680 + (ML20004D680)
- ML20004D681 + (ML20004D681)
- 05000295/LER-1981-003, Forwards LER 81-003/03L-0 + (ML20004D682)
- 05000155/LER-1981-001, Forwards LER 81-001/03L-0 + (ML20004D684)
- 05000298/LER-1981-008-03, /03L-0:on 810426,reactor Vessel Level Switch LIS-72C,Switch-4,caused Continuous Annunciator 9-3-1/8-2 Alarm.Caused by Failure of Yarway Model 4418C Level Indicating Switch,Due to Film Buildup Between Contacts + (ML20004D686)
- ML20004D687 + (ML20004D687)
- 05000267/LER-1981-029-03, /03L-0:on 810420,1D Emergency Diesel Engine of 1B Emergency Generator Set Failed Weekly 50% Load Test. Caused by Failed Injector 1.Injector & Precombustion Chamber Replaced & Generator Returned to Svc + (ML20004D688)
- 05000260/LER-1981-022-03, /03L-0:on 810512,during Performance of High Water Level in Scram,Scram Discharge Vol Level Switch Found Inoperable.Caused by Float Disconnected from Switch Arm. Robertshaw Model SL-305-EI-X Level Switch Replaced + (ML20004D689)
- ML20004D690 + (ML20004D690)
- 05000155/LER-1981-001-03, /03L-0:on 810102,during Specific Gravity Checks, Cell 56 of Reactor Depressurizing Sys Battery for Channel D Had Reading Below 1.200 & Failed to Respond Adequately to Equalizing Charge.Cause Not Known.Cell Replaced on 810108 + (ML20004D691)
- ML20004D692 + (ML20004D692)
- 05000295/LER-1981-003-03, /03L-0:on 810116,while in Hsd for Safe Shutdown & Engineered Safety Feature testing,1A Charging Pump Tripped But Would Not Restart.Caused by Dirty Mechanical Trip Linkage on Breaker.Breaker Replaced + (ML20004D694)
- ML20004D695 + (ML20004D695)
- 05000267/LER-1981-030, Forwards LER 81-030/03L-0 + (ML20004D696)
- ML20004D697 + (ML20004D697)
- IR 05000285/1981006 + (ML20004D698)
- ML20004D699 + (ML20004D699)
- ML20004D701 + (ML20004D701)
- 05000267/LER-1981-030-03, /03L-0:on 810422,during Normal Operation,Two Pressure Transmitters Were Discovered Indicating Low Pressure.Caused by Instrument Drift.Pressure Transmitters Were Calibr + (ML20004D702)
- ML20004D703 + (ML20004D703)
- ML20004D705 + (ML20004D705)
- ML20004D706 + (ML20004D706)
- ML20004D708 + (ML20004D708)
- ML20004D709 + (ML20004D709)
- 05000267/LER-1981-031, Forwards LER 81-031/03L-0 + (ML20004D710)
- ML20004D711 + (ML20004D711)
- IR 05000313/1981013 + (ML20004D712)
- A01645, Responds to IE Bulletin 81-03, Flow Blockage of Cooling Water to Safety Sys Components by Corbicula Sp (Asiatic Clam) & Mytilus Sp (Mussel). No History Exists Indicating Intrusion of Sys by Subj Forms of Life + (ML20004D713)
- 05000265/LER-1981-003-01, /01T-0:on 810202,outboard Steam Isolation Valve MO-2-2301-5 Closed But Would Not Reopen.Caused by Insufficient Torque in Hot Condition to Lift Valve.Valve Limit Switches Adjusted + (ML20004D714)
- ML20004D715 + (ML20004D715)
- ML20004D716 + (ML20004D716)
- 05000267/LER-1981-031-03, /03L-0:on 810427,during Normal Surveillance Testing,Diesel Engine B Tripped & Declutched on Starting. Caused by Load Imbalance Between Engines a & B Due to Normal Wear of Linkage.Linkage Was Adjusted + (ML20004D717)
- ML20004D718 + (ML20004D718)
- 05000296/LER-1981-021, Forwards LER 81-021/03L-0 + (ML20004D719)
- ML20004D720 + (ML20004D720)
- ML20004D721 + (ML20004D721)
- ML20004D722 + (ML20004D722)
- ML20004D723 + (ML20004D723)
- ML20004D724 + (ML20004D724)
- 05000259/LER-1981-022, Forwards LER 81-022/03L-0 + (ML20004D725)
- ML20004D726 + (ML20004D726)
- ML20004D727 + (ML20004D727)
- 05000254/LER-1980-030, Forwards LER 80-030/03L-0 + (ML20004D728)
- ML20004D729 + (ML20004D729)
- 05000296/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20004D730)
- ML20004D731 + (ML20004D731)
- 05000265/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20004D732)