Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19351F506 + (ML19351F506)
- ML19351F507 + (ML19351F507)
- ML19351F508 + (ML19351F508)
- ML19351F509 + (ML19351F509)
- ML19351F510 + (ML19351F510)
- ML19351F511 + (ML19351F511)
- ML19351F512 + (ML19351F512)
- ML19351F513 + (ML19351F513)
- ML19351F514 + (ML19351F514)
- ML19351F515 + (ML19351F515)
- ML19351F516 + (ML19351F516)
- 05000346/LER-1980-091, Forwards LER 80-091/01T-0 + (ML19351F517)
- ML19351F518 + (ML19351F518)
- 05000346/LER-1980-091-01, /01T-0:on 801223,during Analysis Per IE Bulletin 80-11,design for Block Wall Between Control Room & Stairway AB-1 Found to Be Less Conservative than Assumed in Fsar. Caused by Outdated Analytical Const Methods + (ML19351F519)
- ML19351F520 + (ML19351F520)
- ML19351F521 + (ML19351F521)
- ML19351F522 + (ML19351F522)
- ML19351F523 + (ML19351F523)
- 05000334/LER-1980-104-03, /03L-0:on 801204,F-476 Feed Flow Protection Channel for 1A Steam Generator Failed Surveillance Test. Caused by Bad Clock Board Allowing Loop Voltage Drift on Steam Flow Input.Clock Pulse Adjusted + (ML19351F524)
- ML19351F525 + (ML19351F525)
- 05000334/LER-1980-106-03, /03L-0:on 801206,inner Door of Containment Air Lock Failed Surveillance Leakage Test Per Tech Spec.Cause Not stated.O-rings Greased & Valves Tightened + (ML19351F526)
- 05000260/LER-1980-056, Forwards LER 80-056/03L-0 + (ML19351F527)
- ML19351F528 + (ML19351F528)
- 05000334/LER-1980-107-03, /03L-0:on 801206,electrolyte for Detectors 101A & 101B Found Not Dripping.Caused by Clogged Wick & Glass Orifice.Wick & Orifice Cleaned & Top Vent Filter Loosened + (ML19351F529)
- 05000260/LER-1980-056-03, /03L-0:on 801215,reactor Water Level Switch LIS-3-56A Switch 2 Setpoint Found Outside of Tech Spec Limits.Caused by Yarway Model 4418c Setpoint Drift.Switch Recalibr & Functionally Tested for Repeatability + (ML19351F530)
- ML19351F531 + (ML19351F531)
- 05000334/LER-1980-108-03, /03L-0:during Maint Surveillance Procedure for Calibr of Hydrogen Analyzer H2-HY-100B,failed Function Circuit Card Found.Caused by Electronic Circuit Card Failure.Function Card Replaced + (ML19351F532)
- 05000368/LER-1980-056, Forwards Updated LER 80-056/03X-1 + (ML19351F533)
- ML19351F534 + (ML19351F534)
- 05000334/LER-1980-109-03, /03L-0:on 801208,axial Flux Difference Increased Above Target Band.Caused by High Initial Second Fuel Cycle 100% Target Flux Value.Target Flux Value Lowered + (ML19351F535)
- ML19351F536 + (ML19351F536)
- 05000368/LER-1980-056-03, A Core Protection Calculator Received Three Auto Restarts & on 801218, Calculator C Failed Causing Dnbr/Lpd Trip.Probably Caused by Malfunction of Normal Room Cooler Increasing Air Temp + (ML19351F537)
- 05000338/LER-1980-105, Forwards LER 80-105/03L-0 + (ML19351F538)
- ML19351F539 + (ML19351F539)
- 05000295/LER-1980-054, Forwards LER 80-054/03L-0 + (ML19351F540)
- ML19351F542 + (ML19351F542)
- 05000295/LER-1980-053, Forwards LER 80-053/03L-0 + (ML19351F543)
- 05000339/LER-1980-098, Forwards LER 80-098/03L-0 + (ML19351F545)
- ML19351F546 + (ML19351F546)
- 05000296/LER-1980-058, Forwards LER 80-058/03L-0 + (ML19351F547)
- ML19351F548 + (ML19351F548)
- ML19351F550 + (ML19351F550)
- 05000339/LER-1980-097, Forwards LER 80-097/03L-0 + (ML19351F551)
- ML19351F552 + (ML19351F552)
- 05000339/LER-1980-098-03, /03L-0:on 801208,individual Rod Position Indication for Rod J-9 in Shutdown Bank B Deviated from Demand Position by More than 12 Steps.Caused by Instrument Drift.Rod Position Indicator Channel Recalibr + (ML19351F555)
- 05000368/LER-1980-081, Updated LER 80-081/03L-1:on 801030 & 1212,during Repair Work,Fire Barrier Not Maintained.Caused by Inadequate Instructions.Contractor Instructed to Maintain Firewatch When Penetrations Are Open & to Seal Penetrations Quickly + (ML19351F556)
- 05000339/LER-1980-097-03, /03L-0:on 801209 & 10,containment Penetration Conductor for Polar Crane Energized in Mode for Which Breaker Overload Protection Not Qualified.Caused by Closing Breaker 2B1-2A3 for Insp & Work Completion + (ML19351F557)
- 05000312/LER-1980-047, Forwards LER 80-047/01T-0 + (ML19351F559)
- 05000339/LER-1980-099, Forwards LER 80-099/03L-0 + (ML19351F561)
- ML19351F562 + (ML19351F562)
- 05000296/LER-1980-058-03, /03L-0:on 801207,MSIV 1-14,1-15,1-26,1-27,1-37 & 1-38 & 1-51 Found Leaking.Caused by Seating Surface Deterioration Due to Normal Wear.Valves Repaired + (ML19351F563)