ML19351F528

From kanterella
Jump to navigation Jump to search
Forwards LER 80-056/03L-0
Date released: 12/31/2019 Download: ML19351F528


LER 80-056/03L-0:on 801215,reactor Water Level Switch LIS-3-56A Switch 2 Setpoint Found Outside of Tech Spec Limits.Caused by Yarway Model 4418c Setpoint Drift.Switch Recalibr & Functionally Tested for Repeatability
ML19351F530
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 01/06/1981
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19351F530 (2)
Forwards LER 80-056/03L-0
ML19351F527
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 01/06/1981
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19351F527 (1)