- 05000325/LER-1980-085-03, /03L-0:on 801030,switch 3 of 1-B21-LIS-NO31B & D Activated Out of Tolerance.Caused by Instrument Drift. Instruments Recalibr + (ML19345B819)
- 05000324/LER-1980-083, Forwards LER 80-083/01T-0 + (ML19345B820)
- ML19345B821 + (ML19345B821)
- ML19345B822 + (ML19345B822)
- 05000348/LER-1980-068-03, /03L-0:on 801031,B Train River Water Pumps Declared Inoperable Due to Inadequate Lube & Cooling Water Flow.Caused by Dirty Strainers.Strainers Blown Down & Cleaned + (ML19345B823)
- 05000267/LER-1980-070-03, /03L-0:on 801110,during Normal Operation,Emergency Fire Water Pump Removed from Svc to Repack Leaking Pump Gland.Pump Repacked & Returned to Svc + (ML19345B824)
- ML19345B825 + (ML19345B825)
- 05000324/LER-1980-083-01, /01T-0:on 801110,cracked Weld Found in Structural Steel Beam in Reactor Bldg.Caused by Lack of Fusion on Welds of Angle Clips Attaching Beam to Imbedded Wall Plate.Beam Rewelded,Using Larger Clips + (ML19345B826)
- 05000339/LER-1980-090, Forwards LER 80-090/03L-0 + (ML19345B827)
- ML19345B828 + (ML19345B828)
- 05000348/LER-1980-070-03, /03L-0:on 801028,svc Water Bldg Train a Battery Sys Declared Inoperable Due to Low Cell Specific Gravity. Caused by Close Terminal Proximity & Poor Post Seal Design Allowing Formation of Acid Residue Which Shunted Current + (ML19345B829)
- 05000339/LER-1980-090-03, /03L:on 801102,pressurizer Power Operated Relief Valve Declared Inoperable.Caused by Low Nitrogen Pressure Due to Excessive Nitrogen Usage.Pressure Restored by Renewing Supply + (ML19345B830)
- 05000318/LER-1980-050, Forwards LER 80-050/03L-0 + (ML19345B831)
- ML19345B832 + (ML19345B832)
- 05000348/LER-1980-071-03, /03L-0:on 801027 & 28,containment Atmosphere Particuulate & Gaseous Radioactivity Monitoring Sys (R11 & R12) Declared Inoperable Due to Low Flow Pump Trips.Caused by Failing Bearings & Partially Opened Isolation Valve + (ML19345B833)
- 05000339/LER-1980-092, Forwards LER 80-092/03L-0 + (ML19345B834)
- ML19345B835 + (ML19345B835)
- 05000293/LER-1980-085, Forwards LER 80-085/03L-0 + (ML19345B837)
- ML19345B838 + (ML19345B838)
- 05000318/LER-1980-050-03, /03L-0:on 801027,wide Range ex-core Nuclear Instrument Channel B Failed.Caused by Greater than or Equal to 15-volt Dc Power Supply Having Low Supply W/Ac Ripple. Power Supply Replaced + (ML19345B839)
- 05000348/LER-1980-072-03, /03L-0:on 801031,river Water Train B Declared Inoperable When Pump 5 Tripped & Would Not Restart.Caused by Breaker Hea 86 Lockout Relay & 50G Instantaneous Overcurrent Relay Actuation + (ML19345B840)
- 05000339/LER-1980-092-03, /03L-0:on 801103,train B of Safety Injection Sys Failed to Reset Following Functional Test.Caused by Binding in Latching Mechanisms Resulting in Failure of Relays to Reset.Relays Cleaned & Tested Satisfactorily + (ML19345B841)
- ML19345B842 + (ML19345B842)
- 05000293/LER-1980-085-03, /03L-0:on 801023,HPCI Sys Turbine Reached 150% of 4,000 Rpm Full Flow Speed,Rendering Sys Inoperable.Caused by Failure of Turbine Governor & Resistor in Speed Control Circuitry.Governor & Resistor Replaced + (ML19345B843)
- 05000285/LER-1980-025, Forwards LER 80-025/03L-0 + (ML19345B844)
- ML19345B845 + (ML19345B845)
- ML19345B846 + (ML19345B846)
- 05000327/LER-1980-174, Forwards LER 80-174/03L-0 + (ML19345B848)
- ML19345B849 + (ML19345B849)
- ML19345B851 + (ML19345B851)
- ML19345B853 + (ML19345B853)
- 05000285/LER-1980-025-03, /03L-0:on 801027,during Power Operation While Completing Repairs on C Charging Pump,A Charging Pump Became Inoperable.Caused by Leak in Weld Joining Sys to Flushing Line.Weld Repaired & Pump Returned to Svc + (ML19345B854)
- ML19345B855 + (ML19345B855)
- 05000327/LER-1980-174-03, /03L-0:on 801029,during Mode 3,auxiliary Control Room Containment Pressure Indicator 1-PI-30-30C Observed to Be Erroneous When Compared to Other Pressure Indicators.Caused by Incorrect Installation of Sense Line + (ML19345B857)
- 05000338/LER-1980-092, Forwards LER 80-092/03L-0 + (ML19345B859)
- ML19345B860 + (ML19345B860)
- 05000327/LER-1980-179, Forwards LER 80-179/03L-0 + (ML19345B861)
- ML19345B862 + (ML19345B862)
- ML19345B863 + (ML19345B863)
- ML19345B864 + (ML19345B864)
- 05000327/LER-1980-186, Forwards LER 80-186/03L-0 + (ML19345B865)
- ML19345B866 + (ML19345B866)
- 05000338/LER-1980-092-03, /03L-0:on 801030,water Found Leaking from Weld Joint Connecting Drain Valve 1-CH-497 to Piping That Tees Into Suction Line of Charging Pump 1-CH-P-1A.Caused by Bad Weld.Weld Ground Out & Rewelded Per Approved Procedures + (ML19345B867)
- 05000327/LER-1980-179-03, /03L-0:on 801023,review of Surveillance Instructions Revealed That SI-137.2,RCS Water Inventory, Performed Prior to Entering Mode 4 & Not Again Until 801015. Caused by Failure to Revise SI-137.2.Instruction Revised + (ML19345B868)
- ML19345B869 + (ML19345B869)
- 05000302/LER-1980-043, Forwards LER 80-043/04L-1 + (ML19345B870)
- ML19345B871 + (ML19345B871)
- 05000327/LER-1980-186-03, /03L-0:on 801102,during Mode 1,rod Position Indicator E-13,SD Bank A,Became Erratic Then Failed Low. Caused by Defective Connector on Indicator E-13.Spare Connecter F-12 Used Until Defective Connector Repaired + (ML19345B872)
- ML19345B873 + (ML19345B873)
- 05000302/LER-1980-043-04, /04L-1:on 801001,difference of More than Two Std Deviations Discovered Between Preoperational & Operational Studies in Metabolic Function of Discharge Salt Marshes.Probably Caused by Natural or Seasonal Variations + (ML19345B874)
- ML19345B875 + (ML19345B875)