- 05000312/LER-1980-010, Forwards LER 80-010/03L-0 + (ML19344D265)
- 05000312/LER-1980-010-03, /03L-0:on 800213,during Refueling,Polar Crane Moved Over Upender When Upenders Contained New & Irradiated Fuel Assemblies.Caused by Personnel Ignorance of Restrictions in Core Monitor.Handling & Disposal Revised + (ML19344D267)
- ML19344D268 + (ML19344D268)
- ML19344D269 + (ML19344D269)
- ML19344D270 + (ML19344D270)
- ML19344D271 + (ML19344D271)
- ML19344D272 + (ML19344D272)
- 05000346/LER-1980-014, Forwards LER 80-014/03L-0 + (ML19344D273)
- ML19344D274 + (ML19344D274)
- 05000312/LER-1980-009, Forwards LER 80-009/03L-0 + (ML19344D275)
- 05000346/LER-1980-014-03, /03L-0:on 800208,pressurizer Sample Sys Containment Isolation Valve RC240B Failed to Close Twice. Caused by Improper Torque Switch Setting & Stripped Screw on Closing Contactor.Settings Readjusted & Switch Replaced + (ML19344D277)
- ML19344D278 + (ML19344D278)
- ML19344D279 + (ML19344D279)
- ML19344D280 + (ML19344D280)
- ML19344D281 + (ML19344D281)
- 05000312/LER-1980-009-03, /03L-0:on 800207,during Function Tests of Relays in 4,160-volt Feeder Breakers,Contacts Sfax (Sfbx) Found Not Wired.Caused by Discrepancy Between Design & Internal Switchgear Wiring Diagrams.No Changes Necessary + (ML19344D282)
- ML19344D284 + (ML19344D284)
- 05000346/LER-1979-046, Forwards Revised LER 79-046/03L-1 + (ML19344D286)
- ML19344D287 + (ML19344D287)
- 05000334/LER-1980-007-01, Er 80-007/01T-0:on 800121,during Reload After Defueling, Main Filter Banks Found Not in Svc.Caused by Procedural Inadequacy Because None of Refueling Checklists Indicated Tech Spec Change That Required Flow + (ML19344D288)
- 05000346/LER-1979-046-03, During Surveillance Testing,Diesel Generator 1-1 Began Making Loud Noises & Was Declared Inoperable.Caused by Bearing Failure in Turbocharger.Turbocharger Replaced + (ML19344D289)
- 05000333/LER-1980-021, Forwards LER 80-021/03L-0 + (ML19344D291)
- ML19344D293 + (ML19344D293)
- 05000333/LER-1980-021-03, /03L-0:on 800207,during Normal Shutdown Operations Intermediate Range Monitor B Was Made Inoperable to Repair Signal Cable Connector.Reactor Protections Sys B Placed in Tripped Condition.Caused by Normal Wear + (ML19344D295)
- 05000334/LER-1980-010-03, /03L-0:on 800131,refueling Team Was Given Go Ahead for Core Alterations.Fifteen Minutes Later,Inservice Boric Acid Transfer Pump CH-P-2B Tripped on Thermal Overload. Probably Caused by Faulty Blender Controls Shifting Speed + (ML19344D296)
- ML19344D297 + (ML19344D297)
- 05000333/LER-1980-022, Forwards LER 80-022/03L-0 + (ML19344D298)
- ML19344D300 + (ML19344D300)
- 05000333/LER-1980-022-03, /03L-0:on 800208,during Normal Startup Operations, Drywell Atmosphere Monitor a Was Made Inoperable While B Was Out of Svc Resulting in Operation in Degraded Mode.Caused by Need to Investigate Noise from Sample Pump + (ML19344D301)
- 05000334/LER-1980-011-03, /03L-0:on 800226,during Boron Injection Flow Path Verification,Operator Stroked MOV-SI-869A Connecting Charge Sys Fill Header to RCS Hot Leg Piping.Valve Opened & Linestarter Tripped.Caused by Burnt Motor in MOV-SI-869A + (ML19344D302)
- ML19344D303 + (ML19344D303)
- ML19344D305 + (ML19344D305)
- ML19344D306 + (ML19344D306)
- ML19344D307 + (ML19344D307)
- ML19344D308 + (ML19344D308)
- ML19344D310 + (ML19344D310)
- ML19344D311 + (ML19344D311)
- ML19344D312 + (ML19344D312)