ML19344D274

From kanterella
Jump to navigation Jump to search
Forwards LER 80-014/03L-0
Date released: 12/24/2019 Download: ML19344D274


LER 80-014/03L-0:on 800208,pressurizer Sample Sys Containment Isolation Valve RC240B Failed to Close Twice. Caused by Improper Torque Switch Setting & Stripped Screw on Closing Contactor.Settings Readjusted & Switch Replaced
ML19344D277
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 03/06/1980
From: Rudolph J
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19344D277 (3)
Forwards LER 80-014/03L-0
ML19344D273
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 03/06/1980
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19344D273 (1)