Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19341A672 + (ML19341A672)
- ML19341A674 + (ML19341A674)
- 05000320/LER-1980-057-03, /03L-0:on 801217,during Surveillance Procedure 4303-M10,air Intake Tunnel Chlorine Monitor Found Inoperable.Caused by Dirty Probe Which Reduced Sensitivity. Probe Removed,Cleaned & Returned to Svc + (ML19341A675)
- ML19341A677 + (ML19341A677)
- ML19341A678 + (ML19341A678)
- ML19341A679 + (ML19341A679)
- ML19341A680 + (ML19341A680)
- ML19341A681 + (ML19341A681)
- ML19341A682 + (ML19341A682)
- ML19341A684 + (ML19341A684)
- 05000324/LER-1980-114, Forwards LER 80-114/03L-0 + (ML19341A685)
- ML19341A686 + (ML19341A686)
- ML19341A688 + (ML19341A688)
- ML19341A689 + (ML19341A689)
- 05000324/LER-1980-114-03, /03L-0:on 801229,low Level Switch 2B21-LIS-NO31D-3 Actuated Outside Tech Specs.Caused by Instrument Drift. Switch Recalibr + (ML19341A691)
- ML19341A695 + (ML19341A695)
- ML19341A697 + (ML19341A697)
- ML19341A698 + (ML19341A698)
- ML19341A700 + (ML19341A700)
- ML19341A701 + (ML19341A701)
- ML19341A703 + (ML19341A703)
- ML19341A704 + (ML19341A704)
- 05000295/LER-1980-055, Forwards LER 80-055/03L-0 + (ML19341A705)
- ML19341A707 + (ML19341A707)
- 05000295/LER-1980-055-03, /03L-0:on 801216,during Normal Operation,Gas Decay Tank Radiation Monitor ORT-PRO2B Was Taken Out of Svc for Maint & Grab Samples Were Not Taken for Two Shifts.Caused by Personnel Oversight.Personnel Reinstructed + (ML19341A708)
- ML19341A709 + (ML19341A709)
- ML19341A711 + (ML19341A711)
- 05000265/LER-1980-038, Forwards LER 80-038/03L-0 + (ML19341A712)
- ML19341A713 + (ML19341A713)
- ML19341A714 + (ML19341A714)
- ML19341A715 + (ML19341A715)
- ML19341A716 + (ML19341A716)
- 05000265/LER-1980-038-03, /03L-0:on 801210,series of Six Trips Occurred on 2A Reactor Recirculation Pump Motor Generator Set Field Breaker.Caused by Defective Tachometer Which Controls Pump Speed.Tachometer Was Replaced on 801231 + (ML19341A717)
- 05000254/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19341A718)
- ML19341A719 + (ML19341A719)
- ML19341A720 + (ML19341A720)
- 05000254/LER-1980-033-03, /03L-0:on 801217,while Placing Standby Gas Treatment in Normal Standby Operation,Suction Valve MO-1-7503 Failed to Open from Control Room.Caused by Dirty Auxiliary Contacts.Contacts Were Cleaned & Replaced + (ML19341A722)
- 05000298/LER-1980-050, Forwards LER 80-050/03L-0 + (ML19341A723)
- ML19341A724 + (ML19341A724)
- ML19341A725 + (ML19341A725)
- 05000298/LER-1980-050-03, /03L-0:on 801216,during Surveillance Testing of RHR Motor Operated valves,RHR-MO-25B,loop B Injection Line Inboard Isolation Would Not Open.Caused by Installation Error.Close Torque Switch Was Readjusted + (ML19341A726)
- 05000324/LER-1980-118, Forwards LER 80-118/03L-0 + (ML19341A727)
- ML19341A728 + (ML19341A728)
- 05000324/LER-1980-118-03, /03L-0:on 801231,position Indication 38-11 Showed Superimposed 3 Over 8 Digit When at Position 48.Caused by Reed Switch Problem in Rod Prototypic Inlet Piping Probe. Problem Will Be Corrected During Next Available Outage + (ML19341A729)
- 05000324/LER-1980-116, Forwards LER 80-116/03L-0 + (ML19341A730)
- ML19341A731 + (ML19341A731)
- ML19341A732 + (ML19341A732)
- 05000324/LER-1980-116-03, /03L-0:on 801231,pressure Switch 2-E11-PS-N010A Actuated Outside Tech Spec Limits.Caused by Instrument Drift.Switch Recalibr + (ML19341A733)
- ML19341A734 + (ML19341A734)
- ML19341A735 + (ML19341A735)
- ML19341A736 + (ML19341A736)