List of results
- ML19337A278 + (ML19337A278)
- 05000293/LER-1980-047, Forwards LER 80-047/03L-0 + (ML19337A279)
- ML19337A280 + (ML19337A280)
- 05000293/LER-1980-047-03, /03L-0:on 800801,reactor Vessel 203-3D Did Not Respond to Manual Open Signal.Air Operator Assembly,Solenoid Assembly & Pilot Assembly Removed & Tested.No Apparent Cause Determined.Unit Reassembled + (ML19337A281)
- ML19337A284 + (ML19337A284)
- 05000321/LER-1980-097, Forwards LER 80-097/03L-0 + (ML19337A285)
- ML19337A286 + (ML19337A286)
- ML19337A287 + (ML19337A287)
- ML19337A288 + (ML19337A288)
- 05000321/LER-1980-097-03, /03L-0:on 800815,during Reactor Operations at 2370 Mwt,Bldg Vent Radiation Monitor Sample Pump Failed.Caused by Moisture Swelling Pump Carbon Vanes.Pumps Rotated Daily to Prevent Recurrence + (ML19337A289)
- ML19337A291 + (ML19337A291)
- ML19337A292 + (ML19337A292)
- ML19337A294 + (ML19337A294)
- ML19337A295 + (ML19337A295)
- ML19337A297 + (ML19337A297)
- ML19337A298 + (ML19337A298)
- ML19337A299 + (ML19337A299)
- 05000366/LER-1980-124-03, /03L-0:on 800813,during Surveillance of Torus Drywell Vacuum breakers,2T48-F323J Valve Failed to Give Proper Light Indication.On 800827,2T48-F323I Failed in Similar Manner.Cause Not Known + (ML19337A300)
- 05000338/LER-1980-074, Forwards LER 80-074/03L-0 + (ML19337A301)
- ML19337A304 + (ML19337A304)
- 05000285/LER-1980-018, Forwards LER 80-018/03L-0 + (ML19337A305)
- ML19337A309 + (ML19337A309)
- 05000338/LER-1980-074-03, /03L-0:on 800810,w/unit in Mode 1,axial Flux Difference Deviated Greater than 5% from Target & Quadrant Power Tilt Ratio Exceeded 1.02.Caused by Xenon Transient During & After Load Reduction + (ML19337A311)
- 05000285/LER-1980-018-03, /03L-0:on 800808,while Attempting to Monitor Gas Space on Vct,Inadvertent Release of Radioactive Matl to Auxiliary Bldg Environ Occurred.Caused by Deteriorated Surgical Tubing on Gas Analyzer.Tubing Replaced + (ML19337A317)
- 05000285/LER-1980-017, Forwards LER 80-017/03L-0 + (ML19337A322)
- ML19337A323 + (ML19337A323)
- ML19337A325 + (ML19337A325)
- 05000327/LER-1980-143, Forwards LER 80-143/03L-0 + (ML19337A326)
- ML19337A327 + (ML19337A327)
- 05000285/LER-1980-017-03, /03L-0:on 800804,during Normal Power Operation, Personnel Discovered Setpoint Selector Switches for RMO-61, Particulate Radiation Monitor,In Wrong Position.Caused by Personnel Error While Performing Test on Radiation Monitor + (ML19337A329)
- 05000339/LER-1980-037, Forwards LER 80-037/03L-0 + (ML19337A330)
- ML19337A331 + (ML19337A331)
- 05000338/LER-1980-065, Forwards LER 80-065/03L-0 + (ML19337A332)
- ML19337A333 + (ML19337A333)
- 05000327/LER-1980-060, Forwards LER 80-060/03L-0 + (ML19337A334)
- ML19337A335 + (ML19337A335)
- ML19337A336 + (ML19337A336)
- 05000259/LER-1980-059, Forwards LER 80-059/03L-0 + (ML19337A337)
- ML19337A338 + (ML19337A338)
- ML19337A341 + (ML19337A341)
- 05000259/LER-1980-059-03, /03L-0:on 800810,during Normal Operation,Lightning Caused Athens 161 Kv Line to Trip Momentarily.Cooling Tower Transformer Tripped,Causing Loss of 4 Kv Tie Board.Cause of Transformer Trip Unknown.Athens Line re-energized + (ML19337A342)
- ML19337A344 + (ML19337A344)
- ML19337A345 + (ML19337A345)
- ML19337A346 + (ML19337A346)
- ML19337A347 + (ML19337A347)
- 05000339/LER-1980-037-31, /03L-0:on 800807,during Mode 3 Operation,Sample Analysis Indicated High Boron Concentration in SI Accumulators a & C.Caused by Stratification of Boric Acid in Makeup Source or Accumulators + (ML19337A349)
- ML19337A350 + (ML19337A350)
- 05000338/LER-1980-065-03, /03L-0:on 800807-09,w/unit at 100% Power Operation,Control Room Operator Reported Pressurizer Protection Channel III Level Indication Approx 6% Higher than Indications on Channels I & II + (ML19337A351)
- 05000327/LER-1980-143-03, /03L-0:on 800731,during Preoperational Test TVA 56,relay K609 Was Manually Picked Up & Diesel Operators 1B-B,2A-A & 2B-B Failed to Start.Cause Unknown.Generators Were Retested & Subsequently Started on 800801 + (ML19337A352)
- 05000327/LER-1980-060-03, /03L-0:on 800521,ERCW Liquid Effluent Radiation Monitors Were Declared Inoperable Due to Continuous,Sporadic Spiking.Caused by Contactor Chattering on B-B Emergency Gas Treatment Sys Room Cooler Fan Motor + (ML19337A354)
- ML19337A355 + (ML19337A355)