Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19321A056 + (ML19321A056)
- ML19321A057 + (ML19321A057)
- AECM-80-155, Status Deficiency Rept 6 Re Failure to Establish QA Program. GE Has Not Completed Review of Insp Results & Evaluation of Safety Implications.Final Rept to Be Provided by 800908 + (ML19321A060)
- AECM-80-151, Status Deficiency Rept 2 Re Damage to Intermediate Metallic Conduit.Extent & Safety Implications Remain Under Investigation.Final Rept to Be Provided No Later than 801006 + (ML19321A061)
- ML19321A062 + (ML19321A062)
- 05000304/LER-1980-009-03, /03L-0:on 800202,steam Generator Level Transmitter 2LT-538 Had Shifted High by 2.25%.Caused by Transmitter Drift Due to Natural Component Aging.Transmitter Recalibr & Channel Returned to Svc + (ML19321A064)
- ML19321A066 + (ML19321A066)
- 05000295/LER-1980-007, Has Been Cancelled + (ML19321A067)
- 05000295/LER-1980-006, Has Been Cancelled + (ML19321A068)
- 05000295/LER-1980-004, Has Been Cancelled + (ML19321A069)
- 05000295/LER-1979-075, Has Been Cancelled + (ML19321A070)
- 05000295/LER-1979-067, Has Been Cancelled + (ML19321A071)
- 05000295/LER-1979-064, Has Been Cancelled + (ML19321A072)
- 05000304/LER-1980-007-01, Has Been Cancelled + (ML19321A073)
- 05000304/LER-1980-005, Has Been Cancelled + (ML19321A074)
- 05000304/LER-1980-003, Has Been Cancelled + (ML19321A075)
- ML19321A076 + (ML19321A076)
- 05000304/LER-1979-048, Has Been Cancelled + (ML19321A077)
- 05000304/LER-1979-047, Has Been Cancelled + (ML19321A078)
- 05000304/LER-1979-046, Has Been Cancelled + (ML19321A079)
- 05000304/LER-1979-045, Has Been Cancelled + (ML19321A080)
- ML19321A081 + (ML19321A081)
- ML19321A082 + (ML19321A082)
- ML19321A083 + (ML19321A083)
- 05000334/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19321A084)
- ML19321A085 + (ML19321A085)
- ML19321A086 + (ML19321A086)
- ML19321A087 + (ML19321A087)
- 05000334/LER-1980-033-03, /03L-0:on 800617,diesel Generator 1 Governor Control Motor Failed.Caused by Cycling of Governor While Attempting to Shut Down Diesel W/Fast Start Signal Still Applied.Motor Replaced + (ML19321A088)
- ML19321A089 + (ML19321A089)
- ML19321A090 + (ML19321A090)
- ML19321A091 + (ML19321A091)
- ML19321A092 + (ML19321A092)
- 05000295/LER-1980-032, Forwards LER 80-032/03L-0 + (ML19321A093)
- ML19321A095 + (ML19321A095)
- ML19321A096 + (ML19321A096)
- ML19321A097 + (ML19321A097)
- 05000295/LER-1980-032-03, /03L-0:on 800616,fuel Oil Storage Tank Level Found 300 Gallons Less than 40,000 Gallon Limit.Caused by Engineering Assistant Not Anticipating Fuel Consumption Associated W/Diesel Generator Testing Every Three Days + (ML19321A098)
- B10034, Application for Amend to Licenses DPR-21 & DPR-65 to Incorporate Changes to Tech Specs Re Organizational Title. Class I Fee Encl + (ML19321A099)
- 05000346/LER-1980-051, Forwards LER 80-051/03L-0 + (ML19321A101)
- ML19321A102 + (ML19321A102)
- ML19321A103 + (ML19321A103)
- 05000324/LER-1980-048, Forwards LER 80-048/03L-0 + (ML19321A104)
- ML19321A105 + (ML19321A105)
- 05000346/LER-1980-051-03, /03L-0:on 800619,while Performing ST 5031.07 Phase Ii,Sequencer Logic Channels 2 & 4 Did Not Operate as Designed.Caused by Component Failure of Relay Seqx & CR-3X in C3618.Relay Seqx Was replaced.CR-3X Was Cleaned + (ML19321A106)
- ML19321A107 + (ML19321A107)
- 05000327/LER-1980-089, Forwards LER 80-089/03L-0 + (ML19321A108)
- ML19321A109 + (ML19321A109)
- 05000324/LER-1980-048-03, /03L-0:on 800623,low Level Switch 2-B21-LIS-N031A- 1 Would Not Reset When Normal Reactor Water Level Was Simulated.Caused by Stuck Contacts.Defective Switch Replaced & Calibr + (ML19321A110)
- ML19321A111 + (ML19321A111)
- ML19321A112 + (ML19321A112)