Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000324/LER-1980-006-03, /03L-0:on 800103,during Normal Startup,Control Rod 26-07 Had No Position Indication at Notch 48.During 800109 Startup,Rod 34-35 Had No Indication at Notch 7.Caused by Faulty Reed Switches in Prototypical Inlet Piping Probes + (ML19257D854)
- 05000324/LER-1980-003, Forwards LER 80-003/03L-0 + (ML19257D855)
- ML19257D856 + (ML19257D856)
- 05000155/LER-1978-047-03, During Plant Startup, Control Rod Drive Temp on Drive E-2 Exceeded Tech Specs. Caused by Failure of Metal O-Ring Seal at Flange.New Seal Ring Installed Prior to Plant Startup.All O-Rings Replaced + (ML19257D857)
- ML19257D858 + (ML19257D858)
- 05000259/LER-1980-004, Forwards LER 80-004/01T-0 + (ML19257D859)
- ML19257D860 + (ML19257D860)
- 05000324/LER-1980-005, Forwards LER 80-005/03L-0 + (ML19257D861)
- ML19257D862 + (ML19257D862)
- ML19257D863 + (ML19257D863)
- 05000324/LER-1980-003-03, /03L-0:on 800103,during Reactor Startup,Vessel Conductivity Exceeded 2 Umho for 31-h.Caused by Auxiliary Boilers Being Isolated for Months & Supply Lines Containing Stagnant,High Conductivity Water + (ML19257D864)
- 05000324/LER-1980-005-03, /03L-0:on 800105,during Normal Operation,Found Isolation Valve for Pressure Switch 2-E11-PS-N010D Shut. Cause Unknown.Counselled Personnel on Necessity to Follow Procedures to Ensure Proper Instrumentation Svc + (ML19257D865)
- 05000259/LER-1980-004-01, /01T-0:on 800118,during Refueling Outage,Ndt Insp Revealed Linear Indication 7/8 Inch Long in Reactor or Water clean-up Sys Weld DRWC-1-2.Cause Unknown.Defect Will Be Removed & Weld Repaired Prior to Startup + (ML19257D866)
- 05000259/LER-1980-005, Forwards LER 80-005/01T-0 + (ML19257D867)
- ML19257D868 + (ML19257D868)
- 05000259/LER-1980-005-01, /01T-0:on 800118,during Refueling Outage,While Performing Insp Per IE Bulletin 79-14,found No Seismic Restraints in Drywell of Reactor Bldg Closed Cooling Water Piping.Restraints Will Be Installed Prior to Startup + (ML19257D869)
- ML19257D870 + (ML19257D870)
- ML19257D872 + (ML19257D872)
- ML19257D873 + (ML19257D873)
- ML19257D874 + (ML19257D874)
- 05000324/LER-1980-009, Forwards LER 80-009/03L-0 + (ML19257D875)
- ML19257D876 + (ML19257D876)
- 05000324/LER-1980-009-03, /03L-0:on 800114,during Normal Operation, Containment Atmospheric Monitor CAC-AT-1259-1 Failed Upscale.Caused by Loose Ground Connection on Span Potentiometer.Connection Tightened + (ML19257D877)
- ML19257D885 + (ML19257D885)
- ML19257D895 + (ML19257D895)
- ML19257D896 + (ML19257D896)
- ML19257D911 + (ML19257D911)
- ML19257D922 + (ML19257D922)
- ML19257E002 + (ML19257E002)
- ML19257E234 + (ML19257E234)
- ML19257E274 + (ML19257E274)
- ML19257E286 + (ML19257E286)
- ML19257E307 + (ML19257E307)
- ML19257E326 + (ML19257E326)
- ML19257E329 + (ML19257E329)
- ML19257E633 + (ML19257E633)
- ML19257E634 + (ML19257E634)
- ML19257E935 + (ML19257E935)
- ML19257E971 + (ML19257E971)
- ML19257E974 + (ML19257E974)
- ML19257E976 + (ML19257E976)
- ML19257E985 + (ML19257E985)
- ML19257E987 + (ML19257E987)
- ML19257E988 + (ML19257E988)
- ML19257E989 + (ML19257E989)
- ML19257E990 + (ML19257E990)
- ML19257E991 + (ML19257E991)
- ML19257E992 + (ML19257E992)
- ML19257F047 + (ML19257F047)
- ML19257F050 + (ML19257F050)
- ML19257F079 + (ML19257F079)