Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19256A691 + (ML19256A691)
- 05000338/LER-1978-128-03, /03L-0 on 781214: After Main Steam Trip Valve 1-TV-MS-111A Was Opened During Reactor Trip It Failed to Close Fully.Caused by Washer Stuck in Mechanism + (ML19256A692)
- 05000346/LER-1978-101-03, /03L-0,supplemental Info Sheet:On 781005,Component Cooling Water Loop 1 Inoperable Due to Inoperability of Heat Exchanger Outlet Valve.Caused by Missing Nut on Actuator Linkage for Valve.Replaced Linkage Arm Bolt & Set Strok + (ML19256A693)
- 05000336/LER-1978-033, Forwards LER 78-033/03L-0 + (ML19256A694)
- ML19256A695 + (ML19256A695)
- 05000346/LER-1978-120-03, /03L-0 on 781207:containment post-accident Radiation Monitors Re 5029 & 5030 Failed Due to Design Error.Ambient Temp Exceeded Limits & Caused Decomposition of Pump Motor Bearing Grease,Resulting in Bearing Seizure + (ML19256A696)
- 05000338/LER-1978-129-03, /03L-0 on 781219: During Performance of Routine Periodic Test of Reactor Rate Trip Time Constant for Nis Channel N-42, Allowable Time Limits Were Not Observed.Caused by Electronic Drift in Instrumentation + (ML19256A697)
- 05000336/LER-1978-033-03, /03L-0 on 781205:while Operating 12U Diesel for Surveillance,Low Cooling Water Flow Alarm Received.Caused by Shells in the Heat Exhanger + (ML19256A698)
- 05000271/LER-1978-034, Forwards LER 78-034/03L-0 + (ML19256A699)
- ML19256A700 + (ML19256A700)
- 05000338/LER-1978-131-03, /03L-0 on 781211: Alarms for Pressurizer Level Protection Channel L-1460 Were Observed Indicating Tripped Status on a Logic Channel in Protection System. Caused by Blown Fuse in Process Circuitry for the L-1460 Channel + (ML19256A701)
- ML19256A702 + (ML19256A702)
- 05000271/LER-1978-034-03, /03L-0 on 781205:air Ejector Off Gas Monitor a Was Behaving Erratically Drawing Excessive Traces.Condition Could Not Be Reproduced & Cause Is Undetermined.Test Instruments Checked Out Normal + (ML19256A703)
- 05000338/LER-1978-132-03, /03L-0 on 781213:during Periodic Test for Post DBA Hydrogen Analyzer,It Was Found That the Analyzer Indicated 8.5% Less Hydrogen than the Sample Gas Indicated. Recombiner 2-HC-HC-1 Was Declared Inoperable & Analyzer Uncalibr + (ML19256A704)
- 05000029/LER-1978-034, Forwards LER 78-034/03L-0 + (ML19256A705)
- 05000029/LER-1978-034-03, /03L-0 on 781205:during Test,Trip Valve TV-207 Leakage Exceeded Tech Specs Due to Foreign Matl in Valve Seat.Valve Was Cycled Under Pressure & Successfully Retested + (ML19256A707)
- ML19256A708 + (ML19256A708)
- ML19256A709 + (ML19256A709)
- ML19256A710 + (ML19256A710)
- ML19256A712 + (ML19256A712)
- ML19256A714 + (ML19256A714)
- ML19256A715 + (ML19256A715)
- ML19256A716 + (ML19256A716)
- ML19256A718 + (ML19256A718)
- ML19256A719 + (ML19256A719)
- ML19256A720 + (ML19256A720)
- ML19256A727 + (ML19256A727)
- ML19256A728 + (ML19256A728)
- ML19256A729 + (ML19256A729)
- ML19256A730 + (ML19256A730)
- ML19256A731 + (ML19256A731)
- ML19256A733 + (ML19256A733)
- ML19256A735 + (ML19256A735)
- IR 05000338/1978035 + (ML19256A736)
- IR 05000047/1978001 + (ML19256A737)
- ML19256A738 + (ML19256A738)
- ML19256A740 + (ML19256A740)
- ML19256A741 + (ML19256A741)
- ML19256A742 + (ML19256A742)
- ML19256A744 + (ML19256A744)
- IR 05000325/1978032 + (ML19256A745)
- ML19256A747 + (ML19256A747)
- ML19256A748 + (ML19256A748)
- ML19256A749 + (ML19256A749)
- ML19256A750 + (ML19256A750)
- ML19256A751 + (ML19256A751)
- ML19256A752 + (ML19256A752)
- ML19256A753 + (ML19256A753)
- ML19256A755 + (ML19256A755)
- ML19256A756 + (ML19256A756)
- ML19256A757 + (ML19256A757)