License No. DPR-61 APPENDIX A NOTICE OF VIOLATION Based on the result:: of the NRC inspection conducted on November 1-3, 1977, it appears that certain of your activities were not conducted in full compliance with NRC regulations and the conditions of your license as indicated below.
Items A and B are Infractions.
A.
10 CFR 20.101(a) " Exposure of individuals to radiation in restricted areas" requires that no individual receive a dose in excess of seven and one half rem to the skin of the whole body in ariy period of one calendar quarter."
Contrary to this requirement, on October 22, 1977, an individual received a dose to an area of skin of the whole body indicated by thermoluminescent dosimeter evaluation to be at least 22.489 rem.
B.
Technical Specification 6.13 requires that any individual or group of individuals permitted to enter High Radiation Areas in which the intensity of radiation is greater than 100 mrem /hr, must be provided with a radiation monitoring device which continuously indicates the radiation dose rate in the area.
Contrary to this requirement, on October 22, 1977, an individual entered the inner annulus lower level of the containment building without a radiation monitoring device which continuously indicates the dose rate.
Licensee surveys indicate dose rates up to 700 mrem /hr in this area.
This item is recurrent in that findings of a similar nature were identified in Inspection Report 77-05.