- 05000298/LER-1979-025-03, /03L-0:on 790912,HPCI Turbine Stop Valve Separated from Actuator at Split Coupling.Caused by Improperly Mfg Split Coupling.Split Coupling Replaced & Installation Procedures Revised + (ML19250B966)
- ML19250B967 + (ML19250B967)
- ML19250B968 + (ML19250B968)
- 05000266/LER-1979-015, Forwards LER 79-015/01T-0 + (ML19250B969)
- ML19250B970 + (ML19250B970)
- ML19250B972 + (ML19250B972)
- ML19250B973 + (ML19250B973)
- ML19250B974 + (ML19250B974)
- 05000029/LER-1979-024, Forwards LER 79-024/03L-0 + (ML19250B975)
- ML19250B977 + (ML19250B977)
- ML19250B979 + (ML19250B979)
- 05000266/LER-1979-015-01, /01T-0:on 791002,during Normal Power Operation, Loose Tube Fitting Discovered on Common Line from containment-to-containment Pressure Transmitters.Cause Undetermined.Fitting Tightened + (ML19250B981)
- 05000029/LER-1979-024-03, /03L-0:on 791004,during Maint shutdown,CS-MOV-540 Isolated for Repair,Keeping Flow Paths Inoperable.Caused by CS-MOV-540 Leaking by CS-MOV-540 Gate Valve Resulting in Insufficient Gate & Seat Contact.Gate Machined + (ML19250B982)
- 05000237/LER-1979-055, Forwards LER 79-055/03L-0 + (ML19250B983)
- 05000302/LER-1979-097, Forwards LER 79-097/03L-0 + (ML19250B984)
- ML19250B985 + (ML19250B985)
- 05000267/LER-1979-040, Forwards LER 79-040/03L-0 + (ML19250B986)
- ML19250B987 + (ML19250B987)
- ML19250B988 + (ML19250B988)
- 05000029/LER-1979-019, Forwards LER 79-019/04X-0 + (ML19250B989)
- ML19250B991 + (ML19250B991)
- 05000029/LER-1979-019-04, /04X-0:on 790801,direct External Radiation Monitor at Station 9 Was Missing.Cause Unknown.No Corrective Action Planned Other than Replacement of Missing Monitor + (ML19250B992)
- 05000302/LER-1979-097-03, /03L-0:on 791005,chem/rad Sampling Revealed That Reactor Coolant Sys Dose Equivalent I-131 Exceeded 1.0 Uci Per Gram.Caused by Instrument Failure Requiring Removal of Demineralizers from Svc.Dose Reduced & Instrument Repaire + (ML19250B993)
- ML19250B994 + (ML19250B994)
- 05000346/LER-1979-097, Forwards LER 79-097/03L-0 + (ML19250B995)
- ML19250B996 + (ML19250B996)
- ML19250B997 + (ML19250B997)
- 05000237/LER-1979-054, Forwards LER 79-054/03L-0 + (ML19250B998)
- ML19250B999 + (ML19250B999)
- 05000346/LER-1979-097-03, /03L-0:on 791004,steam & Feedwater Rupture Control Sys Channel Supply Failed,Resulting in Half Trip.Caused by Failure of Sorenson Power Supply Which Provides Volt in Channel 4.Power Supply Replaced + (ML19250C000)
- 05000289/LER-1979-016, Forwards LER 79-016/01T-0 + (ML19250C001)
- ML19250C002 + (ML19250C002)
- 05000267/LER-1979-040-03, Ler 79-040/03L-0:on 791001,two Snubbers Required During Power Operation Found Inoperable.Caused by Oil Reservoir Leak in HRS-194 & Loose Lock Nut on HOS-29.Reservoir Refilled & Lock Nut Tightened + (ML19250C003)
- ML19250C004 + (ML19250C004)
- ML19250C005 + (ML19250C005)
- 05000289/LER-1979-016-01, /01T-0:on 791001,error in Seismic Analysis for ladder-type Support for Water Piping May Have Resulted in Exceeding of code-allowable Stresses.Caused by Error in Design Drawings.Engineering Evaluation in Progress + (ML19250C007)
- ML19250C008 + (ML19250C008)
- ML19250C009 + (ML19250C009)
- ML19250C010 + (ML19250C010)
- 05000346/LER-1979-098, Forwards LER 79-098/03L-0 + (ML19250C011)
- ML19250C012 + (ML19250C012)
- 05000267/LER-1979-042, Forwards LER 79-042/03L-0 + (ML19250C013)
- ML19250C014 + (ML19250C014)
- ML19250C015 + (ML19250C015)
- 05000298/LER-1979-024, Forwards LER 79-024/03L-0 + (ML19250C016)
- ML19250C017 + (ML19250C017)
- 05000333/LER-1979-082, Forwards LER 79-082/03L-0 + (ML19250C018)
- ML19250C019 + (ML19250C019)
- 05000237/LER-1979-053, Forwards LER 79-053/03L-0 + (ML19250C020)
- 05000346/LER-1979-098-03, /03L-0:on 791004,during Component Cooling Water Monthly Test,Decay Hear Cooler 1 Component Cooling Outlet Valve CC 1467 Would Not Operate.Caused by Slippage of Valve Linkage.Linkage Realigned & Calibr + (ML19250C021)