- 05000348/LER-1979-040, Forwards LER 79-040/01T-0 + (ML19250A456)
- ML19250A457 + (ML19250A457)
- 05000348/LER-1979-040-01, /01T-0:on 791011,wrong Valves Installed in Piping Sys.Caused by Deficiency in Original Plant Design Equipment Specs.Valves Being Replaced + (ML19250A458)
- 05000267/LER-1979-037, Forwards LER 79-037/03L-0 + (ML19250A459)
- ML19250A460 + (ML19250A460)
- 05000267/LER-1979-037-03, /03L-0:on 790919,during Normal Operation,Liquid Radwaste Release Was Made in Noncompliance W/Limiting Conditions for Operation.Caused by Operator Failure to Reset Flow Switch to New Required Flow Rate.Operators Admonished + (ML19250A461)
- 05000259/LER-1979-024, Forwards LER 79-024/03L-0 + (ML19250A462)
- ML19250A463 + (ML19250A463)
- 05000259/LER-1979-024-03, /03L-0:on 791018,during Normal Operation,Radiation Monitor RM-90-250 Found Erratic & Taken Out of Svc for 1.5-h.Caused by Moisture Collection in Model SC-2B Detector. No Recurrence Control Action Planned + (ML19250A464)
- ML19250A465 + (ML19250A465)
- 05000267/LER-1979-038, Forwards LER 79-038/03L-0 + (ML19250A466)
- ML19250A467 + (ML19250A467)
- ML19250A468 + (ML19250A468)
- 05000267/LER-1979-038-03, /03L-0:on 790921,analytical Sys Primary Coolant Moisture Monitor ME-9307 Became Inoperable W/Reactor at Less than 2% Power.Caused by Burned Out Thermal Electric Heater/Cooler & Two Faulty Relays.Head & Relays Replaced + (ML19250A469)
- ML19250A470 + (ML19250A470)
- ML19250A471 + (ML19250A471)
- 05000334/LER-1979-038, Forwards LER 79-038/03L-0 + (ML19250A472)
- ML19250A473 + (ML19250A473)
- 05000334/LER-1979-038-03, /03L-0:on 790918,vital Bus Inverter 4 Output Frequency Observed Spiking Upscale.Caused by Faulty Oscillator Card in Inverter Control Logic.Inverter Repaired & Returned to Svc + (ML19250A474)
- ML19250A475 + (ML19250A475)
- ML19250A476 + (ML19250A476)
- ML19250A477 + (ML19250A477)
- ML19250A478 + (ML19250A478)
- 05000336/LER-1979-029, Forwards LER 79-029/03L-0 + (ML19250A479)
- ML19250A480 + (ML19250A480)
- ML19250A481 + (ML19250A481)
- ML19250A482 + (ML19250A482)
- ML19250A483 + (ML19250A483)
- ML19250A484 + (ML19250A484)
- ML19250A485 + (ML19250A485)
- ML19250A486 + (ML19250A486)
- 05000324/LER-1979-070, Forwards LER 79-070/03L-0 + (ML19250A487)
- ML19250A488 + (ML19250A488)
- 05000336/LER-1979-029-03, /03L-0:on 790919,B Hydrogen Analyzer Alarms Failed to Clear,Making Detection of Sensor Failure Impossible & Resulting in Hydrogen Analyzer Inoperability.Caused by Failure of Operational Amplifier in Alarm Card + (ML19250A489)
- ML19250A490 + (ML19250A490)
- ML19250A491 + (ML19250A491)
- 05000368/LER-1979-080-03, /03L-0:on 790921,indication for Sodium Hydroxide Addition Tank Discharge Valve 2CV-5667-2 Was Lost.Caused by Failed Power Supply Fuse.Power Fuse Was Replaced & Control Circuit Current Verified + (ML19250A492)
- ML19250A494 + (ML19250A494)
- 05000333/LER-1979-066, Forwards LER 79-066/03X-1 + (ML19250A495)
- ML19250A496 + (ML19250A496)
- ML19250A498 + (ML19250A498)
- 05000282/LER-1979-027-01, /01T-0:on 791002,tube Break Occurred in Steam Generator 11.Caused by Mechanical Wear.Two Defective Tubes Plugged + (ML19250A499)
- 05000333/LER-1979-066-03, /03X-1:on 790907,while Conducting Operations Surveillance Test,Average Power Range Monitor Channels A,D & F Tripped 0.5% Over Tech Spec Requirements.Caused by Operator Error.No Drift of Instrument Setpoint Occurred + (ML19250A500)
- 05000302/LER-1979-088, Forwards LER 79-088/03L-0 + (ML19250A501)
- ML19250A502 + (ML19250A502)
- ML19250A504 + (ML19250A504)
- TXX-3022, Forwards Itt Grinnell Engineering Std ES-13 in Response to IE Bulletin 79-02, Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolt + (ML19250A505)
- ML19250A506 + (ML19250A506)
- 05000302/LER-1979-088-03, /03L-0:on 790918,gaseous Release Monitor RMA-1 Was Found Isolated.Caused by Personnel Error.Monitor Not Properly Returned to Svc Following Filter Replacement. Revision Is Being Made + (ML19250A507)
- ML19250A509 + (ML19250A509)
- 05000333/LER-1979-077, Forwards LER 79-077/04L-0 + (ML19250A511)