ML19250A494

From kanterella
Jump to navigation Jump to search
Forwards LER 79-027/01T-0
Date released: 09/21/2019 Download: ML19250A494


LER 79-027/01T-0:on 791002,tube Break Occurred in Steam Generator 11.Caused by Mechanical Wear.Two Defective Tubes Plugged
ML19250A499
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 10/16/1979
From: Gonyeau J
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19250A499 (43)
Forwards LER 79-027/01T-0
ML19250A493
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 10/16/1979
From: Mayer L
NORTHERN STATES POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19250A493 (1)