- ML19242A803 + (ML19242A803)
- ML19242A804 + (ML19242A804)
- ML19242A805 + (ML19242A805)
- ML19242A806 + (ML19242A806)
- ML19242A807 + (ML19242A807)
- ML19242A808 + (ML19242A808)
- ML19242A809 + (ML19242A809)
- ML19242A810 + (ML19242A810)
- ML19242A811 + (ML19242A811)
- ML19242A812 + (ML19242A812)
- ML19242A813 + (ML19242A813)
- 05000366/LER-1979-069, Forwards LER 79-069/03L-0 + (ML19242A814)
- ML19242A815 + (ML19242A815)
- ML19242A816 + (ML19242A816)
- 05000324/LER-1979-021, Forwards LER 79-021/03L-0 + (ML19242A817)
- ML19242A818 + (ML19242A818)
- ML19242A819 + (ML19242A819)
- 05000366/LER-1979-069-03, /03L-0 on 790712:inboard Steam Isolation Valve (2E51-F001) Did Not Close When Isolation Signal Given. Caused by Valve Stem Being Galled Against Packing Follower. Stem Was Replaced + (ML19242A820)
- 05000324/LER-1979-021-03, /03L-0 on 790702:steam Line Snubber,Pump Suction Snubber & Main Steam Relief Smubbers Found Inoperable. Caused by Seal Failure.Snubbers Rebuilt,Functionally Tested & Reinstalled + (ML19242A821)
- ML19242A822 + (ML19242A822)
- ML19242A823 + (ML19242A823)
- 05000346/LER-1979-075, Forwards LER 79-075/03L-0 + (ML19242A825)
- ML19242A826 + (ML19242A826)
- ML19242A827 + (ML19242A827)
- 05000346/LER-1979-075-03, /03L-0 on 790708:no Visible Oil Level in Outboard Bearing Oil Reservoir Sight Glass on Containment Spray Pump 1-2.Caused by Component Failure.Oil Added to Reservoir & Fittings Tightened + (ML19242A828)
- 05000271/LER-1979-013, Forwards LER 79-013/03L-0 + (ML19242A829)
- ML19242A830 + (ML19242A830)
- 05000333/LER-1979-044, Forwards LER 79-044/03L-0 + (ML19242A831)
- ML19242A832 + (ML19242A832)
- 05000366/LER-1979-067, Forwards LER 79-067/03L-0 + (ML19242A833)
- ML19242A834 + (ML19242A834)
- 05000271/LER-1979-013-03, /03L-0 on 790710:during Testing of RHR Subsys Logic a Relay 10A-K46A Failed to Energize.Caused by Disconnected Lead of Contact to Relay Coils Control Circuit. Wire Was Reconnected & Sys Returned to Operation + (ML19242A835)
- ML19242A836 + (ML19242A836)
- 05000346/LER-1979-072, Forwards LER 79-072/03L-0 + (ML19242A838)
- ML19242A839 + (ML19242A839)
- 05000333/LER-1979-044-03, /03L-0 on 790720:mainstream Line Tunnel Radiation Monitor D Drifted So That Indicator & Trip Point Were Approx 5.5% Low.Caused by Instrument Drift.Instrument Calibr & Tested + (ML19242A840)
- 05000346/LER-1979-072-03, /03L-0 on 790708:position Indication on Rod Two of Group Eight Was Inoperable.Caused by Component Failure of Reed Switch within Position Indicator Tube.Part Was Replaced & Returned to Svc + (ML19242A841)
- 05000366/LER-1979-067-03, /03L-0 on 790707:while Performing Sequence of HPCI Quick Start Test,Breaker for 2E41-F001 Valve Tripped. Caused by Motor Failure on Valve.Motor Was reworked,bench-tested, Reinstalled & Operated Satisfactorily + (ML19242A842)
- ML19242A843 + (ML19242A843)
- 05000346/LER-1979-073, Forwards LER 79-073/03L-0 + (ML19242A844)
- ML19242A845 + (ML19242A845)
- 05000346/LER-1979-073-03, /03L-0 on 790708:during Checkout of Valve Relay, Main Steam Inlet to Auxiliary Feed Pipe Turbine 1-1 Isolation Valve Torqued While Opening.Caused by Normal Valve Wear.Valve Was Readjusted & Returned to Svc + (ML19242A846)
- ML19242A848 + (ML19242A848)
- 05000333/LER-1979-043, Forwards LER 79-043/03L-0 + (ML19242A849)
- ML19242A850 + (ML19242A850)
- ML19242A852 + (ML19242A852)
- 05000325/LER-1979-044, Forwards LER 79-044/03L-0 + (ML19242A853)
- ML19242A854 + (ML19242A854)
- ML19242A855 + (ML19242A855)
- 05000333/LER-1979-043-03, /03L-0 on 790718:discharge Check Valve Associated W/Electric Motor Driven Fire Pump Failed to Properly Reseat Following Pump Shutdown.Caused by Small Pebble Between Valve Clapper & Valve Body.Returned to Svc + (ML19242A856)
- ML19242A857 + (ML19242A857)