- 05000320/LER-1978-033-01, /01T-0 on 780423 Following Reactor Trip,Rcs Rapidly Cooled Down & Depressurized.Main Steam Relief Valves Did Not Reseat at Correct Pressure.Cause Unknown + (ML19206A542)
- ML19206A543 + (ML19206A543)
- 05000320/LER-1978-034-01, /01T-0 on 780424:reactor Trip Caused Main Steam Relief Valves to Lift.Inadequate Design Caused Ejection of Several Steel Liners Used to Protect Bellows + (ML19206A544)
- ML19206A546 + (ML19206A546)
- ML19206A548 + (ML19206A548)
- ML19206A549 + (ML19206A549)
- ML19206A550 + (ML19206A550)
- ML19206A551 + (ML19206A551)
- ML19206A554 + (ML19206A554)
- ML19206A556 + (ML19206A556)
- ML19206A557 + (ML19206A557)
- ML19206A558 + (ML19206A558)
- ML19206A559 + (ML19206A559)
- ML19206A560 + (ML19206A560)
- ML19206A561 + (ML19206A561)
- ML19206A562 + (ML19206A562)
- ML19206A567 + (ML19206A567)
- ML19206A568 + (ML19206A568)
- ML19206A569 + (ML19206A569)
- ML19206A571 + (ML19206A571)
- ML19206A572 + (ML19206A572)
- 05000320/LER-1978-024, Forwards LER 78-024/03L-0 + (ML19206A573)
- 05000320/LER-1978-024-03, /03L-0 on 780404:while in Mode 5,nuclear Svc Closed Cooling Valve Failed to Open.Caused by Malfunction of Solenoid Operated Operator Pilot Valve + (ML19206A575)
- ML19206A576 + (ML19206A576)
- 05000320/LER-1978-002, Forwards LER 78-002/03L-0 + (ML19206A577)
- 05000320/LER-1978-002-03, /03L-0 on 780208:prior to Initial Refueling,Defect Found in Plate 6 of Seismic Instrumentation Triaxial Response Spectrum Recorder 714.Caused by Mfg Error + (ML19206A580)
- 05000320/LER-1978-011, Forwards LER 78-011/03L-0 + (ML19206A581)
- 05000320/LER-1978-011-03, /03L-0 on 780311:entered Mode 4 W/O Establishing Containment Integrity & Surveillance on Bldg Door Not Performed.Door Failure Caused by Damaged O Ring Seals + (ML19206A583)
- 05000320/LER-1978-023, Forwards LER 78-023/03L-0 + (ML19206A584)
- 05000320/LER-1978-023-03, /03L-0:on 780325,while in Mode 4,only One Boron Source Flow Path Verified Operable Prior to Mode 4 Entry. Caused by Clerical Error in Surveillance + (ML19206A586)
- ML19206A587 + (ML19206A587)
- 05000320/LER-1978-026, Forwards LER 78-026/03L-0 + (ML19206A588)
- 05000320/LER-1978-026-03, /03L-0 on 780408:RCS Wide Range Pressure Transmitter RC-3A-PT-4 Failed.Caused by moisture-induced Short Circuit in Terminal Box + (ML19206A590)
- 05000320/LER-1978-013, Forwards LER 78-013/01T-0 + (ML19206A591)
- 05000320/LER-1978-013-01, /01T-0:on 780315,diesel Generator Was Tagged Out of Svc & Redundant Generator Not Demonstrated Operable for 4-h.Caused by Inadequate Review of Tech Specs + (ML19206A594)
- ML19206A595 + (ML19206A595)
- 05000320/LER-1978-004, Forwards LER 78-004/01T-0 + (ML19206A596)
- 05000320/LER-1978-004-01, /01T-0:on 780214,after Initial Fueling,Two Fuel Assemblies Were Loaded Into Reactor Vessel W/O Having Source Range Audible Counts in Containment Bldg + (ML19206A598)