Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18113A843 + (ML18113A843)
- ML18113A844 + (ML18113A844)
- ML18113A845 + (ML18113A845)
- ML18113A846 + (ML18113A846)
- ML18113A847 + (ML18113A847)
- 05000281/LER-1979-002, Forwards LER 79-002/03L-0 & 79-003/03L-0 + (ML18113A848)
- ML18113A849 + (ML18113A849)
- 05000281/LER-1979-002-03, /03L-0 on 790120: During Normal Operation Channel Check Revealed That Pressurizer Pressure Channel I Drifted Above Tech Spec Limit as Compared to Channels II & Iii. Caused by Failure of Channel I Pressure Transmitter + (ML18113A850)
- 05000281/LER-1979-003-03, /03L-0 on 790122: Following Containment Entrance Equipment Hatch Escape Airlock,Outer Door Was Not Proven Sealed within 72-h from Initial Opening.Caused by Problems in Sealing Exterior Hatch + (ML18113A851)
- ML18113A852 + (ML18113A852)
- 05000281/LER-1979-004, Forwards LER 79-004/03L-0 + (ML18113A855)
- ML18113A856 + (ML18113A856)
- 05000281/LER-1979-004-03, /03L-0 on 790204:setpoints of Seven Main Steam Safety Valves Not within Tech Spec Limits.Caused by Normal Setpoint Drift + (ML18113A857)
- 05000280/LER-1979-003, Forwards LER 79-003/03L-0 + (ML18113A858)
- ML18113A859 + (ML18113A859)
- 05000280/LER-1979-003-03, /03L-0 on 790124:error Detected in Calibr Procedures for Steam Flow Instrumentation.Caused by Error Made When Calibr Procedures Changed + (ML18113A860)
- 05000280/LER-1978-047, Forwards LER 78-047/03X-1 + (ML18113A861)
- ML18113A862 + (ML18113A862)
- 05000280/LER-1978-047-03, /03X-1 on 781211:primary to Secondary Leakage in C Steam Generator Exceeded Allowable Limit.Caused by Leakage Through Five Steam Generator Tubes,Combined Flow Resulted in Excessive Leakage + (ML18113A864)
- ML18113A865 + (ML18113A865)
- ML18113A866 + (ML18113A866)
- ML18113A867 + (ML18113A867)
- 05000281/LER-1978-033-03, /03X-1 on 780926:circulating Water Outlet Valve MOV-CW-200D Failed to Close When Operated Electrically. Caused When Actuator Cam for Shut Torque Switch Became Wedged Against Torque Switch Hold Down Screw + (ML18113A868)
- 05000281/LER-1978-038-03, /03X-1 on 781030:boric Acid Flow from Boric Acid Tank to Blender Was Interrupted.Caused by Blockage of Crystallized Boron at Elbow in Line 1-CH-356-152 + (ML18113A869)
- ML18113A870 + (ML18113A870)
- ML18113A872 + (ML18113A872)
- ML18113A874 + (ML18113A874)
- ML18113A875 + (ML18113A875)
- ML18113A876 + (ML18113A876)
- ML18113A877 + (ML18113A877)
- ML18113A879 + (ML18113A879)
- ML18113A881 + (ML18113A881)
- ML18113A882 + (ML18113A882)
- ML18113A883 + (ML18113A883)
- ML18113A885 + (ML18113A885)
- ML18113A886 + (ML18113A886)
- ML18113A887 + (ML18113A887)
- ML18113A888 + (ML18113A888)
- ML18113A890 + (ML18113A890)
- IR 05000280/2018010 + (ML18113A891)
- ML18113A892 + (ML18113A892)
- ML18113A893 + (ML18113A893)
- IR 05000280/1978035 + (ML18113A895)
- ML18113A898 + (ML18113A898)
- ML18113A899 + (ML18113A899)
- 05000281/LER-1979-005-03, /03L-0 on 790204:at Cold Shutdown,Valve MOV-SW-203C Failed to Cycle Electrically.Caused by Slighting Bent Clutch Shaft in Valve Operation.Part Dismantled & Overhauled + (ML18113A900)
- 05000281/LER-1979-006-03, /03L-0 on 790204:at Cold Shutdown,Valve MOV-SW-203D Failed to Operate Electrically During Functional Test.Caused by Mechanical Binding of Valve.Valve Bearing Was Replaced + (ML18113A901)
- 05000281/LER-1979-007-03, /03L-0 on 790205:during Functional Test,Damper 1-VS-103A Failed to Close on Train a Safety Injection Initiation.Caused by Hang Up in Brake Mechanism Holding Supply Damper Open Against Closed Spring.Damper Closed + (ML18113A902)
- ML18113A903 + (ML18113A903)
- ML18113A906 + (ML18113A906)
- ML18113A908 + (ML18113A908)