The following information is a summary pro … The following information is a summary provided by the licensee via phone and email:</br>The affected component is the thermal sleeve in the control rod drive mechanism (CRDM) penetration tube in the replacement Reactor Vessel Closure Head (RVCH) provided to the Callaway plant in 2014. The reportable defect is the unanticipated wear rate of the CRDM thermal sleeve flanges supplied to Callaway as part of the replacement RVCH that was installed in the fall of 2014.</br>During the Callaway refueling outage in the spring of 2025, the thermal sleeve at location H08 was found resting on the upper internals. A ring shaped remnant of the thermal sleeve flange had become separated and was present in the CRDM adapter. </br>Measurements were performed on the remaining CRDM thermal sleeves to determine the amount of thermal sleeve descent from the nominal design configuration. Descent distances ranged from 0.03 to 1.7 inches, with four thermal sleeves having descent of 0.9 inches or more.</br>The failure of a thermal sleeve resulting in a detached flange segment can impact the performance of the corresponding CRDM with the potential to impede or prevent control rod insertion. This issue was first reported under 10 CFR 21 by Westinghouse.</br>Since the identification of the thermal sleeve flange wear issue by Electricite de France (EdF) in 2018, Framatome is unaware of any instances of a control rod failing to insert due to CRDM thermal sleeve events, even at plants which have experienced multiple locations with complete thermal sleeve flange separation.</br>Framatome is conservatively making this notification because the undetected simultaneous failure of multiple thermal sleeves could potentially create a safety hazard if multiple control rods fail to fully insert.</br>Although the causal analysis in still in process, Framatome has reviewed the other replacement RVCHs supplied by Framatome to the US fleet and have not identified any other plants which contain an equivalent combination of conditions that would indicate the potential for accelerated thermal sleeve flange wear. </br>For the other US plants with Framatome supplied replacement RVCHs with thermal sleeves, Framatome will provide a notification to continue using the current and future inspection guidance published by industry bodies.</br>Affected plants: Callaway Energy Center</br>Framatome Contact Information:</br>Gayle Elliott</br>Director, Licensing Regulatory Affairs</br>Framatome Inc.</br>gayle.elliott@framatome.comFramatome Inc.
gayle.elliott@framatome.com
05:00:00, 2 May 2025 +
09:05:00, 11 June 2025 +
05:00:00, 2 May 2025 +
The following information is a summary pro … The following information is a summary provided by the licensee via phone and email:</br>The affected component is the thermal sleeve in the control rod drive mechanism (CRDM) penetration tube in the replacement Reactor Vessel Closure Head (RVCH) provided to the Callaway plant in 2014. The reportable defect is the unanticipated wear rate of the CRDM thermal sleeve flanges supplied to Callaway as part of the replacement RVCH that was installed in the fall of 2014.</br>During the Callaway refueling outage in the spring of 2025, the thermal sleeve at location H08 was found resting on the upper internals. A ring shaped remnant of the thermal sleeve flange had become separated and was present in the CRDM adapter. </br>Measurements were performed on the remaining CRDM thermal sleeves to determine the amount of thermal sleeve descent from the nominal design configuration. Descent distances ranged from 0.03 to 1.7 inches, with four thermal sleeves having descent of 0.9 inches or more.</br>The failure of a thermal sleeve resulting in a detached flange segment can impact the performance of the corresponding CRDM with the potential to impede or prevent control rod insertion. This issue was first reported under 10 CFR 21 by Westinghouse.</br>Since the identification of the thermal sleeve flange wear issue by Electricite de France (EdF) in 2018, Framatome is unaware of any instances of a control rod failing to insert due to CRDM thermal sleeve events, even at plants which have experienced multiple locations with complete thermal sleeve flange separation.</br>Framatome is conservatively making this notification because the undetected simultaneous failure of multiple thermal sleeves could potentially create a safety hazard if multiple control rods fail to fully insert.</br>Although the causal analysis in still in process, Framatome has reviewed the other replacement RVCHs supplied by Framatome to the US fleet and have not identified any other plants which contain an equivalent combination of conditions that would indicate the potential for accelerated thermal sleeve flange wear. </br>For the other US plants with Framatome supplied replacement RVCHs with thermal sleeves, Framatome will provide a notification to continue using the current and future inspection guidance published by industry bodies.</br>Affected plants: Callaway Energy Center</br>Framatome Contact Information:</br>Gayle Elliott</br>Director, Licensing Regulatory Affairs</br>Framatome Inc.</br>gayle.elliott@framatome.comFramatome Inc.
gayle.elliott@framatome.com
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 11 June 2025 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:05, 13 June 2025 +
09:05:00, 11 June 2025 +
40.17 d (964.08 hours, 5.739 weeks, 1.321 months) +
05:00:00, 2 May 2025 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.