The licensee reported that an offsite elec … The licensee reported that an offsite electrical transient on the 230KV transmission line appears to have caused a generator trip and corresponding turbine trip and reactor scram. The scram was uncomplicated. All rods fully inserted. No safety relief valves lifted during the transient. The reactor is stable at 920 psi with decay heat being discharged to the main condenser and fed via the main feed pumps. There was no loss of offsite power during the transient and the plant is in a normal electrical lineup. </br>The specific cause of the generator lockout is still under investigation but is believed to have been caused by maintenance work at the Manitou 230KV substation about 25 miles from the plant. Lightning arrestors were being placed in service at the substation and are believed to have resulted in an electrical disturbance on the grid. The licensee notes that switchgear for the stack lighting did trip during the transient and so the FAA was notified on the stack lighting outage.</br>The licensee plans to remain in hot shutdown for approximately 24 hours before restart.</br>The licensee notified the NRC Resident Inspector.ensee notified the NRC Resident Inspector. +
01:09:00, 2 June 2005 +
41,741 +
23:12:00, 1 June 2005 +
01:09:00, 2 June 2005 +
The licensee reported that an offsite elec … The licensee reported that an offsite electrical transient on the 230KV transmission line appears to have caused a generator trip and corresponding turbine trip and reactor scram. The scram was uncomplicated. All rods fully inserted. No safety relief valves lifted during the transient. The reactor is stable at 920 psi with decay heat being discharged to the main condenser and fed via the main feed pumps. There was no loss of offsite power during the transient and the plant is in a normal electrical lineup. </br>The specific cause of the generator lockout is still under investigation but is believed to have been caused by maintenance work at the Manitou 230KV substation about 25 miles from the plant. Lightning arrestors were being placed in service at the substation and are believed to have resulted in an electrical disturbance on the grid. The licensee notes that switchgear for the stack lighting did trip during the transient and so the FAA was notified on the stack lighting outage.</br>The licensee plans to remain in hot shutdown for approximately 24 hours before restart.</br>The licensee notified the NRC Resident Inspector.ensee notified the NRC Resident Inspector. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 1 June 2005 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:20:54, 2 March 2018 +
23:12:00, 1 June 2005 +
true +
-0.0813 d (-1.95 hours, -0.0116 weeks, -0.00267 months) +
01:09:00, 2 June 2005 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.