Following a downpower to 65% for maintenanFollowing a downpower to 65% for maintenance on one of the reactor feedwater turbines, a main turbine digital electro-hydraulic (DEH) quadvoter valve, that had failed a previous surveillance, was replaced. During the operability testing of the new DEH quadvoter valve, a leak developed. DEH reservoir level dropped 8 inches (approx. 52 gal) and tripped the main turbine on low DEH pressure. An automatic reactor trip occurred due the main turbine trip. All rods fully inserted. RPV pressure was controlled using the bypass valves and main steam line drains. No SRV's opened. RPV level was maintained using the feedwater and condensate system in the normal RPV level band. All other safety systems operated as designed. Off-site power is available. Three emergency diesel generators are operable and available.</br>The licensee has notified the NRC Resident Inspector.e has notified the NRC Resident Inspector.  +
23:06:00, 21 August 2008  +
44,432  +
22:30:00, 21 August 2008  +
23:06:00, 21 August 2008  +
Following a downpower to 65% for maintenanFollowing a downpower to 65% for maintenance on one of the reactor feedwater turbines, a main turbine digital electro-hydraulic (DEH) quadvoter valve, that had failed a previous surveillance, was replaced. During the operability testing of the new DEH quadvoter valve, a leak developed. DEH reservoir level dropped 8 inches (approx. 52 gal) and tripped the main turbine on low DEH pressure. An automatic reactor trip occurred due the main turbine trip. All rods fully inserted. RPV pressure was controlled using the bypass valves and main steam line drains. No SRV's opened. RPV level was maintained using the feedwater and condensate system in the normal RPV level band. All other safety systems operated as designed. Off-site power is available. Three emergency diesel generators are operable and available.</br>The licensee has notified the NRC Resident Inspector.e has notified the NRC Resident Inspector.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 21 August 2008  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:13:49, 2 March 2018  +
22:30:00, 21 August 2008  +
-0.025 d (-0.6 hours, -0.00357 weeks, -8.2188e-4 months)  +
23:06:00, 21 August 2008  +
Automatic Reactor Scram Due to a Main Turbine Trip  +