Crystal River Unit 3 has determined that aCrystal River Unit 3 has determined that an existing condition in the Decay Heat (DH) System is reportable under 10 CFR.50.72 (b)(3)(ii)(B), an Unanalyzed Condition. Two valves in question are in series in the Decay Heat (DH) System drop leg from the Reactor Coolant System (RCS). These valves are High-Low pressure interface valves, where three phase hot shorts from another power cable must be considered under Appendix R. A review of cable routing concluded that the two valve's power cables do not meet required Appendix R separation or protection criteria. As such, there is a low probability that both valves could open due to hot shorts under normal operating RCS pressure and temperature conditions, resulting in a rupture of the downstream piping in the Reactor Building or Auxiliary Building. This event could result in a Loss of Coolant Accident (LOCA) in the Auxiliary Building, which is an unanalyzed condition.</br>The licensee will notify the NRC Resident Inspector.ee will notify the NRC Resident Inspector.  +
21:31:00, 12 January 2007  +
43,098  +
17:19:00, 12 January 2007  +
21:31:00, 12 January 2007  +
Crystal River Unit 3 has determined that aCrystal River Unit 3 has determined that an existing condition in the Decay Heat (DH) System is reportable under 10 CFR.50.72 (b)(3)(ii)(B), an Unanalyzed Condition. Two valves in question are in series in the Decay Heat (DH) System drop leg from the Reactor Coolant System (RCS). These valves are High-Low pressure interface valves, where three phase hot shorts from another power cable must be considered under Appendix R. A review of cable routing concluded that the two valve's power cables do not meet required Appendix R separation or protection criteria. As such, there is a low probability that both valves could open due to hot shorts under normal operating RCS pressure and temperature conditions, resulting in a rupture of the downstream piping in the Reactor Building or Auxiliary Building. This event could result in a Loss of Coolant Accident (LOCA) in the Auxiliary Building, which is an unanalyzed condition.</br>The licensee will notify the NRC Resident Inspector.ee will notify the NRC Resident Inspector.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100  +
00:00:00, 12 January 2007  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:17:23, 2 March 2018  +
17:19:00, 12 January 2007  +
false  +
-0.175 d (-4.2 hours, -0.025 weeks, -0.00575 months)  +
21:31:00, 12 January 2007  +
Unanalyzed Condition of Decay Heat System  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
3  +