Browse wiki
Jump to navigation
Jump to search
100 +
The licensee faxed the following informati … The licensee faxed the following information:</br>On Tuesday, March 29, 2005, Surry Power Station will remove a portion of the Emergency Response Facilities Computer System (ERFCS) in the Main Control Room (MCR) for planned upgrades to a new system for increased reliability and improved human interface design. For approximately 1 week, there will not be a qualified Safety Parameter Display System (SPDS) available in the MCR.</br>During the time period that SPDS is unavailable in the MCR while the upgrade is occurring, the replacement SPDS system is available in the MCR on the Plant Computer System (PCS), but final testing will not qualify the software until completion of this work. There will also remain one ERFCS terminal operable in both the Technical Support Center (TSC) and Local Emergency Operations Facility (LEOF) with operable SPDS throughout the duration of this work. The Emergency Response Data System (ERDS) will remain available from those terminals for the duration of this planned work and normal data transmission capability will remain in the event of an emergency.</br>Since SPDS will be out of service for greater than 1 hour, this report is being submitted in accordance with the guidance in 10CFR50.72(b)(3)(xiii) and NUREG-1022.</br>The licensee has notified the NRC Resident Inspector.</br>* * * UPDATE PROVIDED TO NRC (HUFFMAN) BY DEANE ON 1827 EDT ON 4/7/05 * * *</br>The following information was provided by the licensee via facsimile:</br>This report is an update to previous report EN #41533, dated 03/28/05, regarding the availability of the Emergency Response Facilities Computer System (ERFCS) and Safety Parameter Display System (SPDS) in the main control room for Surry Power Station.</br>The ERFCS and SPDS modifications and testing were completed at 1630 hours on 04/07/05. These functions have been transferred to the Surry Plant Computer System.</br>Senior NRC resident, Norm Garrett was notified via alphanumeric page. Notification was made to NRC duty officer Bill Huffman.</br>R2DO (Rogers) notified.icer Bill Huffman.
R2DO (Rogers) notified.
19:21:00, 28 March 2005 +
41,533 +
14:21:00, 28 March 2005 +
19:21:00, 28 March 2005 +
The licensee faxed the following informati … The licensee faxed the following information:</br>On Tuesday, March 29, 2005, Surry Power Station will remove a portion of the Emergency Response Facilities Computer System (ERFCS) in the Main Control Room (MCR) for planned upgrades to a new system for increased reliability and improved human interface design. For approximately 1 week, there will not be a qualified Safety Parameter Display System (SPDS) available in the MCR.</br>During the time period that SPDS is unavailable in the MCR while the upgrade is occurring, the replacement SPDS system is available in the MCR on the Plant Computer System (PCS), but final testing will not qualify the software until completion of this work. There will also remain one ERFCS terminal operable in both the Technical Support Center (TSC) and Local Emergency Operations Facility (LEOF) with operable SPDS throughout the duration of this work. The Emergency Response Data System (ERDS) will remain available from those terminals for the duration of this planned work and normal data transmission capability will remain in the event of an emergency.</br>Since SPDS will be out of service for greater than 1 hour, this report is being submitted in accordance with the guidance in 10CFR50.72(b)(3)(xiii) and NUREG-1022.</br>The licensee has notified the NRC Resident Inspector.</br>* * * UPDATE PROVIDED TO NRC (HUFFMAN) BY DEANE ON 1827 EDT ON 4/7/05 * * *</br>The following information was provided by the licensee via facsimile:</br>This report is an update to previous report EN #41533, dated 03/28/05, regarding the availability of the Emergency Response Facilities Computer System (ERFCS) and Safety Parameter Display System (SPDS) in the main control room for Surry Power Station.</br>The ERFCS and SPDS modifications and testing were completed at 1630 hours on 04/07/05. These functions have been transferred to the Surry Plant Computer System.</br>Senior NRC resident, Norm Garrett was notified via alphanumeric page. Notification was made to NRC duty officer Bill Huffman.</br>R2DO (Rogers) notified.icer Bill Huffman.
R2DO (Rogers) notified.
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 7 April 2005 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:21:19, 2 March 2018 +
14:21:00, 28 March 2005 +
true +
false +
-0.208 d (-5 hours, -0.0298 weeks, -0.00685 months) +
19:21:00, 28 March 2005 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.