Automatic reactor scram due to a loss of o … Automatic reactor scram due to a loss of offsite power. All rods fully inserted. Supplying power to vital buses via emergency diesel generators. All systems operating properly. </br>NRC Resident Inspector was notified of the event by the licensee.</br>* * * UPDATE 2340EDT ON 8/14/03 FROM ANDY MIHALIK TO S.SANDIN * * *</br>The following information was provided as an update:</br>RPS Actuation (loss of flow) due to loss of offsite power. Auto actuation of AFW in response to the unit trips. Auto start & load of Emergency Diesel Generators in response to the loss of offsite power. Unit 3 also experienced a second AFW auto start during the event. Unit 3 also entered Tech Spec LCO 3.0.3 for loss of two offsite circuits and one EDG inoperable. #31 EDG was declared inoperable when its associated Fuel oil storage tank inventory decreased below required.</br>The licensee informed the state/local authorities and the NRC resident inspector. Notified R1IRC.</br>*****UPDATE ON 8/15/03 AT 0226 FROM CELENTANO TO GOTT*****</br>The licensee exited the Unusual Event at 0210 upon confirmation of a stable off-site power. </br>Notified R1 IRC and FEMA(Heyman).site power.
Notified R1 IRC and FEMA(Heyman). +
20:23:00, 14 August 2003 +
21:50:00, 14 August 2003 +
20:23:00, 14 August 2003 +
Automatic reactor scram due to a loss of o … Automatic reactor scram due to a loss of offsite power. All rods fully inserted. Supplying power to vital buses via emergency diesel generators. All systems operating properly. </br>NRC Resident Inspector was notified of the event by the licensee.</br>* * * UPDATE 2340EDT ON 8/14/03 FROM ANDY MIHALIK TO S.SANDIN * * *</br>The following information was provided as an update:</br>RPS Actuation (loss of flow) due to loss of offsite power. Auto actuation of AFW in response to the unit trips. Auto start & load of Emergency Diesel Generators in response to the loss of offsite power. Unit 3 also experienced a second AFW auto start during the event. Unit 3 also entered Tech Spec LCO 3.0.3 for loss of two offsite circuits and one EDG inoperable. #31 EDG was declared inoperable when its associated Fuel oil storage tank inventory decreased below required.</br>The licensee informed the state/local authorities and the NRC resident inspector. Notified R1IRC.</br>*****UPDATE ON 8/15/03 AT 0226 FROM CELENTANO TO GOTT*****</br>The licensee exited the Unusual Event at 0210 upon confirmation of a stable off-site power. </br>Notified R1 IRC and FEMA(Heyman).site power.
Notified R1 IRC and FEMA(Heyman). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 15 August 2003 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:25:26, 2 March 2018 +
21:50:00, 14 August 2003 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
true +
0.0604 d (1.45 hours, 0.00863 weeks, 0.00199 months) +
20:23:00, 14 August 2003 +