Browse wiki

Jump to navigation Jump to search
A self-revealed finding of very low safetyA self-revealed finding of very low safety significance (Green) and associated NCV of TS 5.4.1(a) were identified when the licensee failed to properly implement plant procedures for placing Component Cooling Water (CCW) Pump 3 in spare status. Specifically, the licensee did not isolate service water (SW) to the standby CCW heat exchanger prior to racking out the CCW Pump 3 breaker. As a result, SW Train 1 header pressure significantly dropped, an automatic isolation of SW cooling and realignment to circulating water cooling from Turbine Plant Cooling Water (TPCW) occurred, and the licensee entered the Loss of SW Abnormal Operating procedure. The condition was corrected, and corrective action documents were generated to review the event. The inspectors determined that the licensees failure to implement procedures for placing CCW Pump 3 in spare status was a performance deficiency that was reasonably within the licensees ability to foresee and correct and should have been prevented. This finding was associated with the Initiating Events Cornerstone of reactor safety and was of more than minor significance because it directly impacted the cornerstone objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. The inspectors evaluated the finding using IMC 0609, Appendix A, The Significance Determination Process for Findings At-Power. Using Exhibit 1, which contains the screening questions for the Initiating Events Cornerstone of reactor safety, the inspectors determined that the finding screened as very low safety significance (Green), because it did not adversely impact any accident, transient, support system loss, steam generator tube rupture, or external event initiators.ube rupture, or external event initiators.  +
23:59:59, 30 June 2013  +
05000346  +
23:59:59, 30 June 2013  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
03:47:40, 28 September 2017  +
23:59:59, 30 June 2013  +
Operations Communications and Work Coordination Error Results in Service Water System Transient  +