ML20207H142  +
05000325  +  and 00325  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +, 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +  and 05000325/LER-1988-018, :on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced +
0.00981 d (0.236 hours, 0.0014 weeks, 3.22664e-4 months)  +, 0.0131 d (0.315 hours, 0.00188 weeks, 4.318675e-4 months)  +, 0.0189 d (0.454 hours, 0.00271 weeks, 6.22498e-4 months)  +  and 0.0128 d (0.306 hours, 0.00182 weeks, 4.19311e-4 months)  +
August 11, 1988  +
1,988  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:42:13, 23 May 2025  +
MST +, ST +, SP +, CP +  and SP-88-200 +
August 11, 1988  +
:on 880713,testing Revealed That HPCI Pump Suction Primary Containment Inboard Isolation Valve Would Not Open.Caused by Loss of Electrical Continuity in Opening Logic.Valve Geared Limit Panel Replaced   +