Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
ML15022A66231 May 2014Teske M
Continuum Dynamics
Acoustic and Low Frequency Hydrodynamic Loads at 115% CLTP Target Power Level on Nine Mile Point Unit 2 Steam Dryer to 250 Hz Using ACM Rev. 4.1R, C.D.I. Report No. 14-09NP, Revision 1, Non-proprietary VersionRequest
ML14216A34728 July 2014Exelon
Swift P
Submittal of Post Extended Power Uprate Steam Dryer Inspection Results in Accordance with Operating License Condition 2.C.(20)(f) and 2.C.(20)(g)Request
ML15022A66131 July 2014Continuum Dynamics
Boschitsch A
Stress Re-Evaluation of Nine Mile Point Unit 2 Steam Dryer at 115% CLTP, CDI Report No. 14-08NP, Revision 0, Non-proprietary VersionRequest
ML14225A22213 August 2014Bhalchandra Vaidya
Plant Licensing Branch I
MF4559, Request for Additional Information Submittal of Post EPU Steam Dryer Inspection Results in Accordance with Operating License Condition 2.C.(20)(f) and 2.C.(20)(g)RAI
ML15023A03014 January 2015Exelon
Swift P
Supplement to Response to Request for Additional Information - Nine Mile Point Unit 2, Submittal of Post Extended Power Uprate Steam Dryer Inspection Results in Accordance with Operating License Condition 2.C.(20)(f) and 2.C.(20)(g)Supplement
ML15027A2583 February 2015Bhalchandra Vaidya
Plant Licensing Branch I
Request for Withholding Information from Public Disclosure Submission Dated 1/14/15, for Supplement to Response to RAI - Submittal of Post Extended Power Uprate Steam Dryer Inspection Results (MF4559)RAI
ML15198A3595 August 2015Mozafari B
Plant Licensing Branch I
Request for Additional Information Regarding Post Extended Power Uprate Steam Dryer Inspection ResultsRAI