Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML20134K313 | 11 February 1997 | NRC (Affiliation Not Assigned) Dick G | Forwards RAI Re Revised SG Tube Rupture Analysis for Mentioned Plants | RAI |
ML20141H353 | 20 May 1997 | NRC (Affiliation Not Assigned) Dick G | Forwards RAI Re Revised Steam Generator Tube Rupture Analysis for Byron Station,Units 1 & 2 & Braidwood Station Units 1 & 2 | RAI |
ML20141H399 | 18 July 1997 | NRC (Affiliation Not Assigned) Dick G | Forwards RAI Re Revised SG Tube Rupture Analysis for Plants, Units 1 & 2 | RAI |
ML20217B390 | 23 September 1997 | NRC (Affiliation Not Assigned) Dick G | Forwards Questions Re Ceco Submittal of Revised SG Tube Rupture Analysis for Byron,Unit 1 & Braidwood,Unit 1 | Other |
ML20217G509 | 3 October 1997 | NRC (Affiliation Not Assigned) Dick G | Forwards RAI Re Revised SG Tube Rupture Analysis Removal of SG Repair Methodologies & Restoration of Previous Dose Equivalent Iodine Limits for Mentioned Plants | RAI |
ML20199G206 | 28 January 1998 | NRC (Affiliation Not Assigned) Dick G | Forwards Safety Evaluation Re Revised SG Tube Rupture Analysis | Approval |
ML20216C600 | 11 March 1998 | NRC (Affiliation Not Assigned) Dick G | Forwards Corrected Pages Re SG Tube Rupture Analysis,To Be Inserted Into SE | Other |
ML20216B648 | 12 May 1998 | Stewart Bailey NRC (Affiliation Not Assigned) | Requests Addl Info Re Revised Steam Generator Tube Rupture Analysis for Byron & Braidwood Stations,Units 1 & 2.Response Requested within 30 Days of Date of Ltr | Other |
ML20207B636 | 25 May 1999 | Stewart Bailey NRC (Affiliation Not Assigned) | Forwards SE Accepting Revised SG Tube Rupture (SGTR) Analysis for Bryon & Braidwood Stations.Revised Analysis Was Submitted to Support SG Replacement at Unit 1 of Each Station | Approval |