Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
ML20134K31311 February 1997NRC (Affiliation Not Assigned)
Dick G
Forwards RAI Re Revised SG Tube Rupture Analysis for Mentioned PlantsRAI
ML20141H35320 May 1997NRC (Affiliation Not Assigned)
Dick G
Forwards RAI Re Revised Steam Generator Tube Rupture Analysis for Byron Station,Units 1 & 2 & Braidwood Station Units 1 & 2RAI
ML20141H39918 July 1997NRC (Affiliation Not Assigned)
Dick G
Forwards RAI Re Revised SG Tube Rupture Analysis for Plants, Units 1 & 2RAI
ML20217B39023 September 1997NRC (Affiliation Not Assigned)
Dick G
Forwards Questions Re Ceco Submittal of Revised SG Tube Rupture Analysis for Byron,Unit 1 & Braidwood,Unit 1Other
ML20217G5093 October 1997NRC (Affiliation Not Assigned)
Dick G
Forwards RAI Re Revised SG Tube Rupture Analysis Removal of SG Repair Methodologies & Restoration of Previous Dose Equivalent Iodine Limits for Mentioned PlantsRAI
ML20199G20628 January 1998NRC (Affiliation Not Assigned)
Dick G
Forwards Safety Evaluation Re Revised SG Tube Rupture AnalysisApproval
ML20216C60011 March 1998NRC (Affiliation Not Assigned)
Dick G
Forwards Corrected Pages Re SG Tube Rupture Analysis,To Be Inserted Into SEOther
ML20216B64812 May 1998Stewart Bailey
NRC (Affiliation Not Assigned)
Requests Addl Info Re Revised Steam Generator Tube Rupture Analysis for Byron & Braidwood Stations,Units 1 & 2.Response Requested within 30 Days of Date of LtrOther
ML20207B63625 May 1999Stewart Bailey
NRC (Affiliation Not Assigned)
Forwards SE Accepting Revised SG Tube Rupture (SGTR) Analysis for Bryon & Braidwood Stations.Revised Analysis Was Submitted to Support SG Replacement at Unit 1 of Each StationApproval