Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML20134F708 | 5 November 1996 | Wetzel B NRC (Affiliation Not Assigned) | Informs That Exhibit D,WCAP-14225,Rev 1, F & Elevated F Tube Plugging Criteria for Tubes W/Degradation in Tubesheet of Prarie Island Units 1 & 2 Steam Generators, Will Be Withheld from Public Disclosure,Per 10CFR2.790 | Other |
ML20129J426 | 5 November 1996 | Wetzel B NRC (Affiliation Not Assigned) | Informs That Amend 1,CEN-620-P,Rev 02-P, Series 44 & 51 Design SG Tube Repair Using Tube Re-Rolling Technique, Marked Proprietary Will Be Withheld from Public Disclosure per,10CFR2.2790(b)(5) & Section 103(b),as Amended | Other |
ML20134K003 | 3 February 1997 | Northern States Power Company Leveille J | Forwards Figure That Goes W/Previous E-mail & More Recent Table of Preliminary Results of Tube Insps | Other |
ML20147E248 | 13 February 1997 | Wetzel B NRC (Affiliation Not Assigned) | Requests Addl Info Re SG Tube Leak Test & Eddy Current Exam Results Obtained During Current Unit 2 Outage & Including Tubes Previously Repaired Using F* Tube Repair Criteria | Other |
ML20134N788 | 19 February 1997 | Wetzel B NRC (Affiliation Not Assigned) | Informs That Amend 1,CEN-620-P,Rev 03-P, Series 44 & 51 Design SG Tube Repair Using Tube Re-Rolling Technique, Will Be Withheld from Public Disclosure,Per 10CFR2.790 | Other |
ML20136D653 | 7 March 1997 | Wetzel B NRC (Affiliation Not Assigned) | Forwards Evaluation of 970213 Request for Info Re Application of F* & Ef* SG Tube Criteria for Plant,Units 1 & 2.Response Consistent W/Original Assessment Provided W/Unit 2 F* License Amend, | Other |
ML20212A350 | 10 October 1997 | Wetzel B NRC (Affiliation Not Assigned) | Requests That Licensee Submit Response to Staff Questions Re Ef* SG Tube Repair Criteria in ,Within 30 Days of Ltr Date or Rquest for Amend Will Be Denied | Other |
ML20199A619 | 10 November 1997 | Northern States Power Company Sorensen J | Responds to 970213 RAI Re 960924 Application for Amend to Licenses DPR-42 & DPR-60 Re Ef SG Tube Repair Criteria. Non-proprietary & Proprietary Versions of Topical Rept CEN-620,rev 4,encl.Proprietary Version,Withheld | Request |
ML20203B367 | 3 February 1998 | Wetzel B NRC (Affiliation Not Assigned) | Advises That Info Re 971110 Application by NSP & CE Original Affidavit, Will Be Withheld from Public Disclosure,Per 10CFR2.790 | Other |
ML20236R916 | 20 July 1998 | Wetzel B NRC (Affiliation Not Assigned) | Advises That Info Contained in ,Attachment 2 (CE Rept CEN-620-P,rev 05P, Series 44 & 451 Design SG Tube Repair Using Tube Rerolling Technique,) Will Be Withheld from Public Disclosure,Per 10CFR2.790(b)(5) | Other |