ML20212A350

From kanterella
Jump to navigation Jump to search

Requests That Licensee Submit Response to Staff Questions Re Ef* SG Tube Repair Criteria in ,Within 30 Days of Ltr Date or Rquest for Amend Will Be Denied
ML20212A350
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 10/10/1997
From: Wetzel B
NRC (Affiliation Not Assigned)
To: Richard Anderson
NORTHERN STATES POWER CO.
References
TAC-M96654, TAC-M96655, NUDOCS 9710230265
Download: ML20212A350 (2)


Text

-

A.

Mr. Roger 0. Anderson. Director Licensing and Management Issues.

Octob.er 10, 1997 Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401

SUBJECT:

RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION CONCERNING EF*

STEAM GENERATOR TUBE REPAIR CRITERIA DATED FEBRUARY 13, 1997.

FOR PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 (TAC NOS. M96654 and M96655)

Dear Mr. Anderson:

By letter dated February 13. 1997, the staff issued a request for adoltional information (RAI) to Northern States Power Company (NSP) regarding application of F* and EF* steam generator tube repair criteria for Prairie Island Nuclear Generating Plant, Units 1 and 2.=

The information pertaining to the.F* tube

-re;;s',e criteria was necessary for the staff to determine, prior to startup of Unit 2 in March 1997, the acceptability for continued service tubes previously re) aired by rerolling. You responded to-the F* questions in a letter dated Fe)ruary 19.1997

.The information pertaining to the EF* tube repair criteria is necessary.for the staff to complete its review of your technical specification amendment request concerning the use of the elevated F* tube s

repair criteria.

NSP has not responded to these questions.

Your response to the staff's RAI has not been timely.

10 CFR 2.108 states in part, the Director of Nuclear Reactor Regulation may deny an application if an applicant fails to respond to a-RAI within 30 days from the date of the request"or within such other time as may be s)ecified.

Please provide your response to the staff's questions regarding E:* tube repair criteria -in our letter dated February 13. 1997, within 30 days of the date of this letter-or your; request for amendment will be denied.

If you have any questions regarding this matter please contact me at 301-415-1355 Sincerely, ORIGINAL SIGNED BY Beth A. Wetzel. Senior Project Manager:

Project Directorate 111,

Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

'4 l

Docket _Nos: 50-282 and 50-306 cc: -See next page DISTRIBUTION:

106ckeMFileil PUBLIC

- PD#3-1--Reading O

EAdensam (EGA1)

OGC ACRS-

)

-JMcCormick-Barger. RIII DOCUMENT NAME: G:\\WPDOCS\\PI96654.LTR To. receive a copy of this document. Indicate in the box C= Copy w/o attachment / enclosure E-Copy with attachment / enclosure N = No copy 0FFICE-PM:PD31 E

LA:PD31 E-D:PD31_

b [$

U "W NAME BWetzel:dbb CJamers N,- JHa M ll!ll!ll) lll[lllll ll DATE -

/0 / 9 /97 f D / 9 /97 m /so /97 9710230265 971010 0F;ICIAL RECORD COPY PDR ADOCK 05000282 P

PDR

o..

e, Mr. Roger O. Anderson, Director Prairie Island Nuclear Generating Northem States Power Compaisy Plant I

j cc:

J. E, Silberg, Esquire Site Licensing Shaw, Pittman, Potts and 1rowbridge Prairie Island Nuclear Generating 2300 N Street, N. W.

Plant Washington DC 20037 Northem States Power Company 1717 Wakonade Drive East Plant Manager Welch, Minnesota 55089 i rairie Island Nuclear Generating Plant Tribal Council Northem States Power Company Prairie Island Indian Community 1717 Wakonade Drive East ATTN: Environmental Department Welch, Mi.inesota 55089 5636 Sturgeon Lake Road Welch, Minnesota 55089 Adonis A. Nebiett Assistant Attomey General Office of the Attomey General 455 Minnesota Sireet Suite 900 St Paul, Minnesota 55101 2127 U.S. Nuclear Regulatory Commission Resident inspector's Office 1

1719 Wakonade Drive East Welch, Minnesota 55089-9642 Regional Administrator, Region ill U.S. Nuclear Regulatory Commission 001 Warrenville Road Lish, lilinois 60532-4351 Mr. Jeft Cole, Auditor / Treasurer Goodhue County Courthouse Box 408 '

Red Wing, Minnesota 55066-0408 Kris Sanda, Commissioner Department of Public Service 121 Seventh Place East Suite 200 St. Paul, Minnesota 55101-2145 wov. mew s m