ML20126L92515 December 1980NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Dodds R
Elin J
Technical Evaluation Rept, Environ Qualification of Safety- Related Electrical Equipment to Harsh EnvironsOther
ML20126L91929 May 1981Office of Nuclear Reactor RegulationSafety Evaluation Re Environ Qualification of safety-related Electrical Equipment.No Outstanding Items Requiring Immediate Corrective Action.Completion of Corrective Actions by 820630 Will Ensure Compliance W/Nrc 800523 MemorandumApproval
ML20054L8491 July 1982SACRAMENTO MUNICIPAL UTILITY DISTRICT
Mattimoe J
Forwards Current Schedule for Installation of Qualified Electrical Equipment.Evaluation Worksheets & Test Repts Have Not Been Sent for Item II.D.3, Valve Position Indication, Since Five of Six Units Tested FailedOther
ML20085J33510 October 1983WEC Energy Group
Burstein S
Discusses 831013 Meeting to Resolve Deficiencies Noted in Franklin Research Ctr Technical Evaluation Rept Re Environ Qualification of safety-related Electrical Equipment.Agenda & Supporting Documentation EnclMeeting
ML20108D8621 March 1985Southern Nuclear
Gucwa L
Requests Further Extension of 850331 outage-based Equipment Qualification Deadline for Hydrogen/Oxygen Analyzers.Revised Schedule for Completion of Qualification Testing on Hydrogen/Oxygen Analyzers EnclOther
ML20112H30827 March 1985Southern Nuclear
Gucwa L
Requests Expedited Relief from Current 850331 Equipment Qualification Deadline for Facility Drywell & Oxygen Analyzers Until 851130 Due to Recent Change in Schedule for Upcoming Refueling OutageOther
ML20100L0179 April 1985Southern Nuclear
Gucwa L
Forwards Application Fee,Per NRC ,To Cover 850301 Request for Extension of 10CFR50.49 Equipment Qualification Deadline for Drywell Hydrogen & Oxygen Analyzers Currently Installed at FacilityRequest
ML20128A03928 June 1985Reinaldo Rodriguez
SACRAMENTO MUNICIPAL UTILITY DISTRICT
Submits Supplemental Info Re Questions Raised During Equipment Qualification (EQ) Insp During Wk of 850520. T-drains on Limitorque Motor Operators Replaced W/Plugs.All EQ Procedures Approved & Ready for UseSupplement
ML20137E99816 August 1985Southern Nuclear
Gucwa L
Notifies of Problems That May Necessitate Extension of Equipment Qualification Deadline for Primary Containment Hydrogen & Oxygen Gas Analyzers,Per 10CFR50.49(h).Revised Testing Schedule for Analyzers EnclOther
ML20137T68127 November 1985Southern Nuclear
Gucwa L
Provides Status of Environ Qualification Effort for Drywell Hydrogen & Oxygen analyzers.Architect-engineer Determined Equipment Located in Mild Environ Will Remain Operable During & for at Least 180 Days Following LOCAOther