Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML18100A188 | 11 April 2013 | Minnesota Xcel Energy TriVis | Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination | Other |
ML18100A185 | 11 April 2013 | Minnesota Xcel Energy | Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH Nuhoms Canisters | Other |
ML18100A191 | 30 January 2014 | Minnesota Xcel Energy Structural Integrity Associates Rich Smith TriVis | Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear Nuhoms 61BTH Type 1 & 2 Transportable Canister for BWR Fuel | Other |
ML18100A190 | 22 May 2014 | Minnesota Xcel Energy Structural Integrity Associates Rich Smith | Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records | Other |
ML18065A548 | 6 March 2018 | Christian Jacobs Spent Fuel Licensing Branch | EnclosuRAI-1 (non-proprietary) (Letter to T. J. O'Connor First Request for Additional Information for Review of Exemption Request for Five Nonconforming Dry Shielded Canisters 11 Through 15) | RAI |
ML18065A545 | 6 March 2018 | Package: First Request for Additional Information for Review of Exemption Request for Five Nonconforming Dry Shielded Canisters 11 Through 15 (CAC No. 001028, Docket No. 72-58, EPID L-2017-LLE-0029) | Request | |
ML18065A546 | 6 March 2018 | Christian Jacobs Spent Fuel Licensing Branch | Letter to T. J. O'Connor First Request for Additional Information for Review of Exemption Request for Five Nonconforming Dry Shielded Canisters 11 Through 15 (CAC No. 001028, Docket No. 72-58, EPID L-2017-LLE-0029) | RAI |
ML18100A193 | 5 April 2018 | Minnesota Xcel Energy TN Americas LLC | Enclosure 13 - Tn Americas LLC Calculation 11042-0207, Revision 1, Nuhoms 61BTH Type 1 DSC Itcp and Otcp Maximum Weld Flaw Evaluation | Other |
L-MT-18-013, Response to Request for Additional Information Regarding Exemption Request for Nonconforming Dye Penetrant Examinations of Dry Shielded Canisters (Dscs) 11 Through 15 | 5 April 2018 | Minnesota Xcel Energy O'Connor T | Response to Request for Additional Information Regarding Exemption Request for Nonconforming Dye Penetrant Examinations of Dry Shielded Canisters (Dscs) 11 Through 15 | Response to RAI |
ML18121A250 | 1 May 2018 | Package: 05/01/2018, E-Mail from C. Jacobs/Dsfm to S. Jurek Monticello Exemption: NRC Clarification Questions on RAI#1 Responses | Request | |
L-MT-18-034, Supplement to Exemption Request for Nonconforming Dye Penetrant Examinations of Dry Shielded Canisters (Dscs) 11 Through 15 (CAC No. 001028, EPID L-2017-LLE-0029 | 31 May 2018 | Minnesota Xcel Energy O'Connor T | Supplement to Exemption Request for Nonconforming Dye Penetrant Examinations of Dry Shielded Canisters (Dscs) 11 Through 15 (CAC No. 001028, EPID L-2017-LLE-0029 | Supplement |
ML18248A121 | 13 September 2018 | John Mckirgan Spent Fuel Licensing Branch | Federal Register Notice: Exemption; Issuance - Xcel Energy, Monticello Nuclear Generating Plant Independent Spent Fuel Storage Installation | Other |
ML18262A378 | 20 September 2018 | John Mckirgan Spent Fuel Licensing Branch | Letter to T.O'Connor Exemption from Certain Provisions of 10 CFR 72.212 and 72.214 - Storage Standardized Nuhoms Dry Shielded Canisters 11-15 at Monticello Nuclear Generating Plant Isfsi(Cac No.001028, Dockets 72-58 and 50-263, EPID L-2017- | Approval |