Semantic search

Jump to navigation Jump to search
 Issue dateTitleFromTo
NRC Generic Letter 1995-0717 August 1995NRC Generic Letter 1995-007: Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate ValvesCrutchfield D
Office of Nuclear Reactor Regulation
ML18101B06016 October 1995Responds to GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves.Eric Simpson
PSEG
Office of Information Resources Management
Information Notice 1996-05, Partial Bypass of Shutdown Cooling Flow from Reactor Vessel18 January 1996Partial Bypass of Shutdown Cooling Flow from Reactor VesselCrutchfield D
Office of Nuclear Reactor Regulation
Information Notice 1996-08, Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate Valve5 February 1996Thermally Induced Pressure Locking of a High Pressure Coolant Injection Gate ValveCrutchfield D
Office of Nuclear Reactor Regulation
ML18101B2159 February 1996LER 96-002-00:on 960110,motor Operated Gate Valves Found Susceptible to Pressure Locking & Thermal Binding.Caused by Noncompliance W/Gl 95-07 Requirements for Pressure Locking & Thermal Binding.Suppl Expected on 960315.W/960209 LtrPSEG
Warren C
Hassler D
Office of Information Resources Management
ML20149K14113 February 1996Submits Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate ValvesEric Simpson
PSEG
Office of Information Resources Management
ML18101B27815 March 1996LER 96-022-01:on 960110,evaluation Determined That Motor Operated Gate Valves Susceptible to Pressure Locking & Thermal Binding.Caused by Inability to Meet GL 95-07 Criteria.Test Procedure changed.W/960318 LtrPSEG
Warren C
Hassler D
Office of Information Resources Management
ML18102A24715 July 1996LER 96-008-00:on 960613,failed to Meet Tech Spec Requirement While in Mode 5 for Natural Circulation.Caused by Insufficient Technical Input for Development of Controls. Revised Operating Logs for Mode 5.W/960711 LtrPSEG
Garchow D
Hassler D
Office of Information Resources Management
ML18102A2955 August 1996Responds to RAI Re GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves.PSEG
Dawn Powell
Office of Information Resources Management
ML18102A2967 August 1996Responds to RAI Re GL 95-07, Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves. Supersedes 960805 LtrPSEG
Dawn Powell
Office of Information Resources Management
Information Notice 1996-49, Thermally Induced Pressurization of Nuclear Power Facility Piping20 August 1996Thermally Induced Pressurization of Nuclear Power Facility PipingMartin T
Office of Nuclear Reactor Regulation
ML18102A36130 August 1996Provides Supplemental Info to Support Response to GL 95-07, Pressure Locking & Thermal Binding of Safety Related Power Operated Gate Valves.PSEG
Dawn Powell
Office of Information Resources Management
ML18102A38931 August 1996Monthly Operating Rept for Aug 1996 for Salem Unit 2. W/960911 LtrPSEG
Garchow D
Phillips R
Heller R
Office of Information Resources Management
ML18102A46730 September 1996Monthly Operating Rept for Sept 1996 for Salem Unit 2. W/961014 LtrPSEG
Garchow D
Heller R
Office of Information Resources Management
Information Notice 1997-07, Problems Identified During Generic Letter 89-10 Closeout Inspections6 March 1997Problems Identified During Generic Letter 89-10 Closeout InspectionsMartin T
Office of Nuclear Reactor Regulation
ML18102B4377 July 1997LER 96-008-01:on 960613,failure to Meet TS Requirements While in Mode 5 for Natural Circulation Was Noted.Caused by Insufficient Technical Input for Development of Controls. Revised Plant Operating Logs for Mode 5.W/970707 LtrPSEG
Garchow D
Bernard Thomas
Office of Information Resources Management
ML18102B46724 July 1997Responds to 970610 RAI Re GL 95-07, Presssure Locking & Thermal Binding of Safety Related Power Operated Gate Valves.PSEG
Dawn Powell
Office of Information Resources Management
ML18102B5167 August 1997LER 97-009-00:on 970711,failure to Stroke Pump Discharge Valves for Potential Pressure Locking Concern Was Noted. Caused by Personnel Error.Revised Procedures to Address Addl Instances of CS Pump operation.W/970811 LtrMel Gray
PSEG
Garchow D
Office of Information Resources Management
ML18102B55822 August 1997Forwards Response to 970610 RAI Re Util'S Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power Operated Gate Valves. Validated Results Re Valve Susceptability to Pressure Locking Thermal Binding,ProvidedPSEG
Dawn Powell
Office of Information Resources Management
ML18107A33024 May 1999Forwards Suppl Info Re GL 95-07, Pressure Locking & Thermal Binding of Safety Related Power Operated Gate Valves. Encl Contains Methodology Used in Determination of Pressure Locking Susceptibility of PORVs Block ValvesEric Simpson
PSEG
Office of Information Resources Management
IR 05000272/200800722 September 2008IR 05000272-08-007, 05000311-08-007; on 07/14/2008 - 08/08/2008; Salem Nuclear Generating Station Units 1 and 2; Component Design Bases InspectionDoerflein L
Engineering Region 1 Branch 2
PSEG
Levis W
IR 05000272/201400727 August 2014IR 05000272-14-007 and 05000311-14-007; 06/23/2014 - 07/24/2014; Salem Unit Nos. 1 and 2; Component Design Bases Inspection (CDBI)Christopher Cahill
Engineering Region 1 Branch 2
PSEG
Joyce T
ML20135H31914 May 2020Final ASP Analysis - Salem 1 and 2 (LER 272-96-002)NRC/RES/DRA/PRB
Christopher Hunter