CP-201101030, Transmittal of Unit 1 Inservice Inspection Program Plan, Revision 6, (Unit 1: ASME Code XI 1998 Edition, 1999 and 2000 Addenda, Interval Start - August 13, 2000, Second Interval) | 2 August 2011 | Transmittal of Unit 1 Inservice Inspection Program Plan, Revision 6, (Unit 1: ASME Code XI 1998 Edition, 1999 and 2000 Addenda, Interval Start - August 13, 2000, Second Interval) | Non-Destructive Examination Weld Overlay Hydrostatic VT-2 Eddy Current Testing Liquid penetrant Through-Wall Leakage Dissimilar Metal Weld |
ML080520195 | 10 March 2008 | Relief Request B-5 for Second 10-Year ISI Interval from 10 CFR 50.55a Requirements for Class 1 Repair/Replacement of Control Rod Drive Mechanism Canopy Seal Welds | Boric Acid High Radiation Area Weld Overlay Nondestructive Examination Incorporated by reference Stress corrosion cracking Liquid penetrant |
CP-200800348, Transmittal of Inservice Inspection Program Plan, Revision 3, (ASME Code Section XI 1998 Edition, 1999 and 2000 Addenda, Interval Start Date August 3, 2004, Second Interval) | 6 March 2008 | Transmittal of Inservice Inspection Program Plan, Revision 3, (ASME Code Section XI 1998 Edition, 1999 and 2000 Addenda, Interval Start Date August 3, 2004, Second Interval) | High Radiation Area Non-Destructive Examination Weld Overlay Hydrostatic VT-2 Eddy Current Testing Liquid penetrant Dissimilar Metal Weld |
ML080430662 | 29 February 2008 | Request for Relief No. B-4 from Certain Requirements of ASME Code, Section XI for Implementation of the EPRI-PDI Supplement 11 Program and Application of Weld Overlays | Weld Overlay Hydrostatic Nondestructive Examination Incorporated by reference Dissimilar Metal Weld |
ML072270704 | 12 September 2007 | Relief Request for Implementation of the EPRI-PDI Supplement 11 Program Requirements, and Weld Overlays, Relief Request B-6 (Tac No. MD3315) | Weld Overlay Hydrostatic Nondestructive Examination Incorporated by reference Intergranular Stress Corrosion Cracking Dissimilar Metal Weld |
CPSES-200701302, Relief Request B-4 to the Unit 2 Inservice Inspection (ISI) Program Plan from the 1998 Edition of ASME Code, Section XI, Through 2000 Addenda (Interval Start Date - August 03, 2004, Second Interval) | 22 August 2007 | Relief Request B-4 to the Unit 2 Inservice Inspection (ISI) Program Plan from the 1998 Edition of ASME Code, Section XI, Through 2000 Addenda (Interval Start Date - August 03, 2004, Second Interval) | Weld Overlay Hydrostatic Nondestructive Examination Intergranular Stress Corrosion Cracking Stress corrosion cracking Liquid penetrant Dissimilar Metal Weld DM weld |
CPSES-200700229, Comanche, Response to Request for Additional Information, Relief Request B-6 for the Unit 1 Inservice Inspection (ISI) Program Plan from the 1998 Edition of ASME Code, Section XI, Through 2000 Addenda (Interval Start Date.. | 2 February 2007 | Comanche, Response to Request for Additional Information, Relief Request B-6 for the Unit 1 Inservice Inspection (ISI) Program Plan from the 1998 Edition of ASME Code, Section XI, Through 2000 Addenda (Interval Start Date.. | Weld Overlay Stress corrosion cracking |
ML070240464 | 24 January 2007 | E-Mail to Fred Madden and Timothy Hope, Txu Power, from Mohan Thadani, Nrc/Nrr - Request for Additional Information - Relief Request No. B-6 | Weld Overlay |
CPSES-200601983, Relief Request B-6 to Unit 1 Inservice Inspection Program Plan from the 1998 Edition of ASME Code, Section XI, Through 2000 Addenda (Interval Start Date - August 13, 2000, Second Interval) | 3 October 2006 | Relief Request B-6 to Unit 1 Inservice Inspection Program Plan from the 1998 Edition of ASME Code, Section XI, Through 2000 Addenda (Interval Start Date - August 13, 2000, Second Interval) | Weld Overlay Hydrostatic Nondestructive Examination Intergranular Stress Corrosion Cracking Stress corrosion cracking Liquid penetrant Dissimilar Metal Weld DM weld |
ML030800600 | 21 March 2003 | Regarding Relief from the Requirements of the ASME Bwrvp Code, Section XI, Concerning Relief Request B-10 for Repair or Replacement of Control Rod Drive Mechanism Canopy Seal Welds | Boric Acid Weld Overlay Nondestructive Examination Incorporated by reference Stress corrosion cracking Liquid penetrant |
CPSES-200300265, Relief Request B-10 for Second 10 Year ISI Interval from 10 CFR 50.55a Requirements for Class I Repair/Replacement of CRDM Canopy Seal Weld (Second Interval Start Date: August 2003) | 11 February 2003 | Relief Request B-10 for Second 10 Year ISI Interval from 10 CFR 50.55a Requirements for Class I Repair/Replacement of CRDM Canopy Seal Weld (Second Interval Start Date: August 2003) | Boric Acid Weld Overlay Nondestructive Examination Stress corrosion cracking Liquid penetrant |
ML030060001 | 3 January 2003 | ASME Code Relief Request B-3 for CRDM Canopy Weld Repair/Replacement, MB6867 | Boric Acid Weld Overlay Nondestructive Examination Incorporated by reference Stress corrosion cracking Liquid penetrant |
CPSES-200203940, Relief Request B-3 for Second 10 Year ISI Interval from 10 CFR 50.55a Requirements for Class 1 the Repair/Replacement of CRDM Canopy Seal Weld (Interval Start Date: August 13, 2000, Second Interval) | 6 December 2002 | Relief Request B-3 for Second 10 Year ISI Interval from 10 CFR 50.55a Requirements for Class 1 the Repair/Replacement of CRDM Canopy Seal Weld (Interval Start Date: August 13, 2000, Second Interval) | Boric Acid Weld Overlay Nondestructive Examination Stress corrosion cracking Liquid penetrant |