ML20210Q920 | 12 August 1999 | Safety Evaluation Supporting Amends 36 & 45 to Licenses R-38 & R-67,respectively | |
ML20206F424 | 27 April 1999 | Rev 2 to General Atomics Triga Reactor Facility Decommissioning Plan | |
ML20195E656 | 31 December 1998 | Triga Mark I Reactor Annual Rept for CY98, Dtd Apr 1999 | |
ML20203C463 | 16 October 1998 | Issue a to QAPD-9009-2, Triga Reactor Facility Decommissioning QA Program Document | |
ML20154B485 | 1 October 1998 | Safety Evaluation Supporting Amend 44 to License R-67 | |
ML20216G067 | 31 December 1997 | Triga Mark I Reactor Annual Rept CY97 | |
ML20212G420 | 29 October 1997 | Safety Evaluation Supporting Amend 35 to License R-38 | Shutdown Margin Fuel cladding |
ML20211P346 | 9 October 1997 | Safety Evaluation Supporting Amend 34 to License R-38 | |
ML20140D509 | 18 April 1997 | Rev 0 to General Atomics Triga Reactor Facility Decommissioning Plan | High Radiation Area Squib Earthquake |
ML20137U154 | 31 December 1996 | Triga Mark I Reactor Annual Rept for CY96 | |
ML20134E635 | 10 June 1996 | Partially Deleted Commission Paper Re Financial Assurance for General Atomics Facilities | |
ML20062D540 | 5 November 1990 | Ro:On 901029,coupling Assembly Connecting Control Rod to Drive Mechanism Misaligned | |
ML20248C608 | 3 August 1989 | Ro:On 890726,apparent Release of Fission Products from Fuel Element Occurred.Caused by Spent Fuel Element 6368.Fuel Element Removed from Core & Placed in Spent Fuel Storage | |
ML20244A853 | 6 April 1989 | Ro:On 890330,anomaly Discovered at Top End of Rod Worth Curve.Caused by Missing Aluminum Spacer.All Spare Rod Mark F Drive Assemblies Being Checked to Ensure Presence of Aluminum Spacers | Shutdown Margin |
ML20235Q375 | 16 February 1989 | Triga Mark I Annual Rept for 1988 | |
ML20235Q094 | 16 February 1989 | Triga Mark F Annual Rept for 1988 | |
ML20055H019 | 31 December 1988 | Safety Evaluation Under 10CFR50.59 Microprocessor-Based Instrumentation & Control Sys for General Atomics Triga Mark I Reactor | |
ML20206J283 | 18 November 1988 | Safety Evaluation Supporting Amend 40 to License R-67 | |
ML20147A768 | 23 February 1988 | Annual Operating Rept for 1987 | Fuel cladding |
ML20149N113 | 22 February 1988 | Annual Operating Rept for 1987 | |
ML20236T222 | 6 November 1987 | Ro:On 871030,deputy physicist-in-charge (DPIC) Bypassed Cylinder Down Limit Microswitch & Failed to Check Action of Interlock Sys When Checking Operation of Maintained Control Transient Rod.Maint Overhaul on Sys Ordered & DPIC Rebuked | |
ML20237G696 | 31 August 1987 | Safety Evaluation Report on HIGH-URANIUM Content, LOW-ENRICHED URANIUM-ZIRCONIUM Hydride Fuels for Triga Reactors.Docket No. 50-163.(GA Technologies,Incorporated) | |
ML20235E998 | 6 July 1987 | Safety Evaluation Supporting Amend 38 to License R-67 | |
ML20209C468 | 10 April 1987 | Safety Evaluation Supporting Amend 27 to License R-38 | |
ML20206G111 | 7 April 1987 | Ro:On 870320,operator Incorrectly Lowered Pulse Rod Receiver to Reduce Core Excess Reactivity.Caused by Human Error.Matl Re Problem Will Be Introduced Into Requalification Training Course | |
ML20205A193 | 19 March 1987 | Safety Evaluation Supporting Amend 37 to License R-67 | |
ML20212C334 | 25 February 1987 | Annual Operating Rept for 1986 | |
ML20207P813 | 9 January 1987 | Ro:On 870105,safety Rod Did Not Drop After Termination of Customer Irradiation & Reactor Scram.Mesh Screen Protecting Rod Barrel from Debris Discovered to Be Too Tight & Binding Rod.Control Rods Recalibr on 870108 | |
ML20205Q210 | 15 September 1986 | Speech Entitled, Current Status of U Zirconium-Hydride Low Enriched U Fuel Design & Development, Presented at Seventh European Triga Users Conference on 820915-17 in Istanbul, Turkey | Fuel cladding |
ML20203F958 | 31 July 1986 | Revised Decommissioning Plan | |
ML20206A864 | 5 June 1986 | Ro:On 860527,after Reactor Startup Following 10-day Programmed Shutdown,Readings of Certain Thermionics Data Showed Slightly Higher Secondary Pressure than Desired. Fused Light Circuit Not Operating.Right Fuse Installed | |
ML20154B335 | 27 February 1986 | Annual Operating Rept for 1985,discussing Operating Experience,Changes in Design,Performance Characteristics & Procedures,Fuel,Control Rod,Pulsing Sys & Reactor Safety Surveillances & Continuous Air Monitor | |
ML20154B465 | 27 February 1986 | Annual Operating Rept for 1985 | |
ML20212C290 | 25 February 1986 | Annual Operating Rept for 1986 | |
ML20140C333 | 20 February 1986 | Safety Evaluation Supporting Amend 36 to License R-67 | |
ML20137X708 | 20 February 1986 | Safety Evaluation Supporting Amend 35 to License R-67 | |
ML20137W581 | 13 February 1986 | Ro:On 860125,air Pump Which Circulates Air Through Particulate Filter in Continuous Air Monitor Found Not Functioning.Caused by Partially Inserted Power Cord Plug. Plug Inserted Properly & Pump Returned to Operation | |
ML20140C442 | 21 January 1986 | Ro:On 851229,cell Top Monitor Exhibited Apparent Loss of Sensitivity During Startup.Electronic Count Rate/Power Supply Package (Eberline RM-14) Replaced | |
ML20136F251 | 14 November 1985 | Ro:On 851030-1107,Channel K-3 Scram Level Set 9% Higher than Tech Spec Limit.Caused by Erroneous Entry in Log Book.Scram Setpoint for Channel Corrected | |
ML20133K326 | 17 October 1985 | Safety Evaluation Supporting Amend 35 to License R-67 | |
ML20205Q219 | 14 October 1985 | Speech Entitled, Final Results of Qualification Testing of Triga Fuel in Oak Ridge Research Reactor Including Post- Irradiation Exam, Presented at 851014-16 Meeting in Petten,The Netherlands | |
ML20128L826 | 13 June 1985 | Safety Evaluation Supporting Amend 34 to License R-67 | |
ML20054L930 | 25 February 1982 | Annual Financial Rept 1981 | |
ML20062B305 | 15 September 1978 | Ro:On 780831,while at Full Power,Control Rod Continued to Withdraw Even When Operator Not Depressing Up Control. Caused by Faulty Switch.Switch Replaced |