!Um November 5,1990 r
l Document Control Desk U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, Maryland 20852
Subject:
Docket No. 50-89: Reactor Facility License No. R-3P; Reportable -
Occurrence Gentlemen:
At approximately 1400 hours0.0162 days <br />0.389 hours <br />0.00231 weeks <br />5.327e-4 months <br /> on Monday, October 29, 1990, General Atomics (GA) notified the Region V office of the Nuclear Regulatory Commission of an occurrence involving GA's TRIGA Mark I reactor (License R-38), _ which had occurred earlier that day.
This report was made to Mr. Greg Yuhas - with a l
follow up by a report on October 30 to the regional office - by Dr. Junald Razvi, Physicist-in-Charge of GA's TRIGA Reactors - Facility, and Dr. Keith i
Asmussen, Manager.(PIC) ing and Nuclear Compliance.
Licens While the occurrence may-not have been a "reportabl3" occurrence, we nevertheless reported it to the regional office to keep the commission fully informed of the problem.
Accordingly, the circumstances of the event are described herein and subm!tted within 10 days as required by the applicable license.
j Sequence of Events j
After making a core excess reactivity measurement as the. final ste) in = the completion of the dally startup checklist procedure the oparator decidec to dro) rods individually to shutdown, in order to obtain rod drop times on each roc.
I Measurement of rod drop times is 3 art of the checks of various reactor systems performed on a weekly basis, and (1e operator was a'. tempting to take this data upon completion of the core excess measurement in order to complete part of the i
weekly checklist requirement.
The sequence of events is adequately described by the operator's logbook entry:
i i
" Manually scramming individual rods to measure drop times" "0235 TR
. % sec"
[
t Shim 1 - 0.94 sec" Shim 2 - 0.67 sec" Reg
- 1.29 sec*"
"* rod will not scram-via magnet switch - must use manual scram" 9011130312 901105
. 2, g i
PDR ADOCK 05000089
. 7 l
S PDC j
i 10955 JOHN JAY HoPKINS OFUVE, SAN DIEGo, cA 92121.194 Po box 05608. SAN DIEGo, cA 92138-$608 -
(619)455-3000 '
l
.f*
.mu
I Document Control Desk November 5,1990 Page Two The inability of the regulating rod to drop as described above was subsequently reported to the Associate Plc at ~0730 the same day, and no subsequent reactor runs were performed by the operator.
Analysis and troubleshooting revealed that the problem was not in the magnet current interrupt switch, but in the control rod drive hardware.
Part of the coupling assembly connecting the control rod to the drive mechanism was not properly aligned, which caused the rod drop times to be longer than expected.
When the magnet current interrupt switch - which is not part of the scram loop on the reactor, but is used for momentary interruption of magnet current to drop individual rods - was used to drop the rod, the momentary interruption was inadequate to free the rod from the magnet, hence the rod did not drop.
However, when the scram loop was opened by using the manual scram switch, magnet current was cut to the electromagnets, and the rod fell, although a fraction of a second (but noticeably) slower than other rods. Note however that the minimum scram time of two seconds or less continued to be met.
We then proceeded to have the control rod drive and associated connecting hardware nmoved for further troubleshooting and repair.
Analysis in June,1990, the control rod drives on the Mark I reactor were upgraded to new stepping motor (DC) drives as part of hardware upgrades that were being performed on the reactor.
To make this changeover, a new upper connecting rod was fabricated, which is coupled to the original piston rod via flange connectors (see attached drawings).
Upon removal and a careful evaluation of this assembly for the re was found that the old piston rod section had a noticeable bend (gulating rod, itwobble") in it when compared to the upper connecting rod.
This wobble had a measured eccentricity of 1/4-inch (1/2-inch overall side to side motion).
The cause of the wobble was found to be a slight mlsailgnment at the flange section of the piston rod.
This misalignment caused the lower connecting rod fplston rod) to sllchtly rub on the teflon washer located in the bottom of the barrel assembly, which slightly impeded the free motion of the rod.
Corrective Action The problem was corrected by machining the flange surfaces of both the piston and connecting rods to remove approximately 10 mils of metal from the surfaces.
Doing this reduced the wobble to an eccentricity of about 10 mils (20 mils side to side motion), which is acceptable for proper control rod action.
j l
i Document Control Desk l
November 5,1990 l
l Page Three l
(
The poison section of the control rod war removed from its guide - tube and checked for rub rnarks and scratches beyond those already documented from the l
The control rod assembly was reassembled, rod drop times and rod worth remen-
=
previous inspection.
No signs of scratching or. additional rub marks were noted.
l sured, and normal reactor operations were resumed at approximately 1500 on Tuesday, October 30, 1990.
The installation was reviewed, inspected and accepted I
I by the Plc and the Safety Committee prior to resumption of operations.
While visual inspection of the other control rods and measurement of rod drop.
times do not indicate any type of problems with the other two standard control rods, they will be carefully examined for the above symptoms during the. scheduled core inspection in December,1990.
We trust you will find the above description of the occurrence and corrective actions satisfactory.
If you have questions concerning this report, you may contact me at (619)455-2441.
l Very tr
- yours, 40 C
Junaid Razvi, Director Radiation Services and Physicist-in-Charge
/]r cc:
Mr. John B. Martin, Administrator, NRC Region V i
b h
1 1
n
-..y.
a
. r...
}?eG Rob cavrvEcT)NG Reb A Ss EN8L.y l
. /. '. ;.s u.*v u,w. !
h-6 DIMYING "[DS?TOb ~190 gSy Y : h..ln.f.....f.
~;. '.,.
.y. (':n,
,..y.
-ts!
's.{ g, C l
.. :u ;l........ l.
.....x..,
(
.' o -
1
.di
.., $ w..
o
,t
- g..,.
- a..
-. >.. g.,..
- sq,.,
i;'....
, ~ '
u
.. y s
~
... c ',,..,.
., '.~.s s
s v
i
- b....,
.. gg g
-. :,. m : --
, F~L.hvG 6 -
~
1,t
. c.onuEc~n H& Rob
~
3 Pi.rrw Ro.D t
h'. -
2 u~~
.PIDbW A4 (OL'b)
~ ~
VPPeX conugc:T1NG 00D (N N)
.~
}l '.
- G(
3 l;
A
.e 0
e h
4-MA6NE't END
~
Pow..secnoa l\\
Roo uwc sao
---.+
t \\
\\
l t
e
.s s.
'as...
- 3
'6 4
Pic > + *?
a e ma,...;
1
+.
s
,, s 6
=*
I*4 S-
..,1 s
)
e s.
O
.e b
\\
0
'6 e
m
n.
..'.-l f-- -
~
^ ^h -
ATTAc# NENT 2
~
)
4
- 4 f
.i I
t
{,,-
jg w
O I
, y, SO
^
s r
6/'
b i'
'i
]I.
s t
.t ld' l \\,
')
0 g
g g l I6
.k !
_c0 a
g h
- t. &'
', ' U h-l 2
b d.-
T 7
'f h':l m
- 1, 2 r iS aj' g
s y
D I
j h e,tg, s'
- ggu, i
n s
6
,,)
Q p
3y w y:
. n.,.
\\
w 1% :$se& 9N5 t,y oc a
w
.s rva J
i l
.J
/.p N'
e4 s
stie y
IA 3
11 0
a 4-A
{
i
- 2. "~ 4 1 s
N t
I
-)
D 9
=
f s
u,
\\
h i
k m
i J.
q D
gU w e s
nn M 4 %'
^
O g M J
- 3' p
{
h n
a m
s j
I 1
,i 1
l