Issue date | Title | Topic | |
---|---|---|---|
ML20237E957 | 27 August 1998 | Start-Up Test Rept Vynp Cycle 20 | Shutdown Margin Hydrostatic |
ML20149M745 | 24 January 1997 | Startup Test Rept,Vermont Yankee Cycle 19 | Shutdown Margin |
ML20086Q713 | 25 July 1995 | Startup Test Rept,Vermont Yankee Cycle 18 | Shutdown Margin |
ML20063A418 | 13 January 1994 | Startup Test Rept for Vermont Yankee Cycle 17 | Shutdown Margin Enforcement Discretion |
ML20102A593 | 8 July 1992 | Reactor Containment Integrated Leak Rate Test,Vermont Yankee Nuclear Power Station | Anchor Darling |
ML20101L098 | 1 July 1992 | Startup Test Rept Vermont Yankee Cycle 16 | Shutdown Margin |
ML20066H889 | 23 January 1991 | Cycle 15 Startup Test Rept | Shutdown Margin |
ML19354E802 | 16 January 1990 | Room Integrity Testing of Vermont Yankee Cable Spreading Room, Final Rept | |
ML20245C432 | 14 June 1989 | Startup Test Rept Vermont Yankee Cycle 14 | Shutdown Margin |
ML20246L468 | 30 April 1989 | Primary Containment Leak Rate Test 1989 | |
ML20196E276 | 5 December 1988 | Emergency Response Facilities Info Sys Isolator Type Test Summary | |
ML20234E924 | 4 January 1988 | Startup Test Rept,Vermont Yankee Cycle 13 | Shutdown Margin |
ML20215E462 | 30 November 1986 | Voltage Study for Split Group Bus Configuration | |
ML20203N957 | 6 October 1986 | Startup Test Rept Vermont Yankee Cycle 12 | Shutdown Margin |
ML20215D809 | 30 June 1986 | Primary Containment Leakage Rate Testing, 1986 | |
ML20099E988 | 6 November 1984 | Startup Test Rept, Vermont Yankee Cycle 11 | Shutdown Margin |
ML20108D848 | 15 May 1984 | Final Rept on Exam,Testing & Evaluation of Irradiated Pressure Vessel Surveillance Specimens from Vermont Yankee Nuclear Power Station | |
FVY-83-100, Startup Test Rept Vermont Yankee Cycle 10 | 15 September 1983 | Startup Test Rept Vermont Yankee Cycle 10 | Shutdown Margin |
ML20076L603 | 13 September 1983 | Primary Containment Leakage Rate Testing, 1983 | |
ML20071A817 | 9 February 1983 | VT Yankee Cycle 10 Core Performance Analysis,Jan 1983 | Shutdown Margin Feedwater Controller Failure Fuel cladding |
ML20049H626 | 25 February 1982 | Cycle IX Startup Test Rept. | Shutdown Margin |
ML20010F459 | 31 August 1981 | Cycle 9 Core Performance Analysis. | Shutdown Margin Feedwater Controller Failure Fuel cladding |
ML20003G527 | 17 February 1981 | CTP-0205,3-H Fire Exposure Test Per ASTM E-119 W/Hose Steam:5 Inch Depth CT-800/GE RTV 6428 Silicone Elastomer. | |
ML19350D114 | 31 December 1980 | Primary Containment Leakage Rate Testing,1980. | Reactor Vessel Water Level |
ML19309A749 | 24 March 1980 | Inadvertently Deleted Page of Cycle VII Startup Test Rept. | Shutdown Margin |
ML19257C641 | 18 January 1980 | Startup Test Rept,Cycle 7 | Shutdown Margin |
ML19257C280 | 31 December 1979 | Primary Containment Leak Rate Testing, for 1978-79 | Reactor Vessel Water Level |
ML19274D225 | 5 January 1979 | Test Rept:Startup Began on 781010 Following 3-week Outage. Describes Process Computer Data Checks,Shutdown Margin testing,in-sequence Critical,Rod Scram Tests,Thermal Hydraulic Limits & Power Distribution | Shutdown Margin |
ML20023A400 | 17 November 1978 | Primary Containment Leakage Rate Testing 1974-1978.Describes All Reactor Containment Testing Performed Subsequent to the Oct 1974 Type a Test & Up to & Incl a Type a Test Performed in Aug 1978 | |
ML20081B978 | 7 February 1972 | Integrated Primary Containment Leakage Rate Test |