 Issue dateTitleTopic
PY-CEI-NRR-2393, Special Rept Update:On 990327 Refueling Outage 7 Began & Troubleshooting Efforts Began.Troubleshooting of Affected Calbe Confirmed Fault in Drywell Section of Cable.Determined That Installation of Newer Technology Should Be Explored12 May 1999Special Rept Update:On 990327 Refueling Outage 7 Began & Troubleshooting Efforts Began.Troubleshooting of Affected Calbe Confirmed Fault in Drywell Section of Cable.Determined That Installation of Newer Technology Should Be ExploredPost Accident Monitoring
PY-CEI-NRR-2369, Special Rept:On 990127,PAMI Was Declared Inoperable.Caused by Low Resistance Reading Existing in Circuit That Goes to Drywell.Troubleshooting of Affected Cable Will Commence During RFO on 9902273 March 1999Special Rept:On 990127,PAMI Was Declared Inoperable.Caused by Low Resistance Reading Existing in Circuit That Goes to Drywell.Troubleshooting of Affected Cable Will Commence During RFO on 990227Post Accident Monitoring
PY-CEI-NRR-2208, Special Rept Re Inoperable Post Accident Monitoring Instrumentation.Efforts in Progress to Restore Instrumentation as Soon as Possible,But No Later than End of Upcoming Refueling Outage Scheduled to Begin 97091226 August 1997Special Rept Re Inoperable Post Accident Monitoring Instrumentation.Efforts in Progress to Restore Instrumentation as Soon as Possible,But No Later than End of Upcoming Refueling Outage Scheduled to Begin 970912Post Accident Monitoring
PY-CEI-NRR-2090, Special Rept:On 960814,channel of Post Accident Monitoring Instrumentation Was Inoperable 24 H More than OOS Time Allowed by Ts.Instrumentation Has Been Repaired & Operable26 August 1996Special Rept:On 960814,channel of Post Accident Monitoring Instrumentation Was Inoperable 24 H More than OOS Time Allowed by Ts.Instrumentation Has Been Repaired & OperablePost Accident Monitoring
PY-CEI-NRR-2056, Special Rept:On 960421,channel of Vibration & Loose Parts Monitoring Sys Declared Inoperable,Due to Abnormally Low Background Level Being Detected.Cause for Low Output Signal Cannot Be Determined31 May 1996Special Rept:On 960421,channel of Vibration & Loose Parts Monitoring Sys Declared Inoperable,Due to Abnormally Low Background Level Being Detected.Cause for Low Output Signal Cannot Be Determined
PY-CEI-NRR-2019, Special Rept:On 951228,six Channels of Vibration & Loose Parts Monitoring Sys Declared Inoperable Because 18 Month Channel Calibr Surveillance Frequency Had Passed.Performs Daily Channel Checks & Monthly Channel Functioning Testing5 February 1996Special Rept:On 951228,six Channels of Vibration & Loose Parts Monitoring Sys Declared Inoperable Because 18 Month Channel Calibr Surveillance Frequency Had Passed.Performs Daily Channel Checks & Monthly Channel Functioning Testing
PY-CEI-NRR-1946, Special Rept:On 950405,Unit Vent Gas Post Accident Radiation Monitoring Channel Was Declared Inoperable Based on Results of Testing Conducted in Accordance W/Surveillance Instruction SVI-D19-T535319 April 1995Special Rept:On 950405,Unit Vent Gas Post Accident Radiation Monitoring Channel Was Declared Inoperable Based on Results of Testing Conducted in Accordance W/Surveillance Instruction SVI-D19-T5353
PY-CEI-NRR-1923, Special Rept:On 950303,vibration & Loose Parts Monitoring (V&Lpm) Sys Channels 1 & 4 Inoperable for More than 30 Days. V&Lpm Channels 1 & 4 Declared Inoperable on 950201 Subsequent to Troubleshooting Activities13 March 1995Special Rept:On 950303,vibration & Loose Parts Monitoring (V&Lpm) Sys Channels 1 & 4 Inoperable for More than 30 Days. V&Lpm Channels 1 & 4 Declared Inoperable on 950201 Subsequent to Troubleshooting Activities
PY-CEI-NRR-1857, Special Rept:On 940825,offgas Ventilation Exhaust Post Accident RM Declared Inoperable & Exceeded 72 H Limit on 940828 When New Flow Control Circuit Card Would Not Calibr Properly.Original Circuit Card Reinstalled & Calibr8 September 1994Special Rept:On 940825,offgas Ventilation Exhaust Post Accident RM Declared Inoperable & Exceeded 72 H Limit on 940828 When New Flow Control Circuit Card Would Not Calibr Properly.Original Circuit Card Reinstalled & Calibr
PY-CEI-NRR-1837, Special Rept:On 940515 & 0618,ECCS Manual Actuations W/ Injection Into RCS Occurred as Part of Preplanned Activities for Testing8 August 1994Special Rept:On 940515 & 0618,ECCS Manual Actuations W/ Injection Into RCS Occurred as Part of Preplanned Activities for Testing
PY-CEI-NRR-1755, Seismic Rept:On 940107,triaxial time-history Accelerographs for Reactor Building & Containment Vessel Declared Inoperable During Performance of Surveillance Testing. Amplifier Card & Motor Driver Card Replaced16 February 1994Seismic Rept:On 940107,triaxial time-history Accelerographs for Reactor Building & Containment Vessel Declared Inoperable During Performance of Surveillance Testing. Amplifier Card & Motor Driver Card ReplacedEarthquake
PY-CEI-NRR-1531, Special Rept:On 920618,Vibration & Loose Part Monitoring (V&Lpm) Sys Experienced Series of Invalid Alarms Due to Excessive Background Noise.Channel 7 of V&Lpm Sys Declared Inoperable.V&Lpm Sys Upgraded28 July 1992Special Rept:On 920618,Vibration & Loose Part Monitoring (V&Lpm) Sys Experienced Series of Invalid Alarms Due to Excessive Background Noise.Channel 7 of V&Lpm Sys Declared Inoperable.V&Lpm Sys Upgraded
PY-CEI-NRR-1486, Special Rept:On 920315,small Earthquake Occurred 4 Miles Northwest of Plant.On 920323,seismic Recorders Removed from Svc & Remained Inoperable for More than 30 Days.Several Instrumented Locations Available to Record Motion1 May 1992Special Rept:On 920315,small Earthquake Occurred 4 Miles Northwest of Plant.On 920323,seismic Recorders Removed from Svc & Remained Inoperable for More than 30 Days.Several Instrumented Locations Available to Record MotionEarthquake
PY-CEI-NRR-1360, Special Rept:On 910418,alarms Generated by Noise Spike in 60 Hz Range Due to Inoperable Loose Parts in Detection Sys Instrumentation.Possible Corrective Actions Include Replacement of Cable or Detector28 May 1991Special Rept:On 910418,alarms Generated by Noise Spike in 60 Hz Range Due to Inoperable Loose Parts in Detection Sys Instrumentation.Possible Corrective Actions Include Replacement of Cable or Detector
PY-CEI-NRR-1342, Special Rept:On 910319,turbine Bldg/Heater Bay Vent Post Accident Radiation Monitor Declared Inoperable to Facilitate Performance of Calibr Procedure.Work Order Revised to Replace Failed Regulator5 April 1991Special Rept:On 910319,turbine Bldg/Heater Bay Vent Post Accident Radiation Monitor Declared Inoperable to Facilitate Performance of Calibr Procedure.Work Order Revised to Replace Failed RegulatorGrab sample
PY-CEI-NRR-1315, Special Rept:On 910115,channel 8 of Vibration & Loose Parts Monitoring Sys Experienced Spurious Alarms That Could Not Be Reset.Caused by Alarm Threshold Set Too Sensitively.Alarm Threshold Raised to Value Comparable W/Channel 725 February 1991Special Rept:On 910115,channel 8 of Vibration & Loose Parts Monitoring Sys Experienced Spurious Alarms That Could Not Be Reset.Caused by Alarm Threshold Set Too Sensitively.Alarm Threshold Raised to Value Comparable W/Channel 7
PY-CEI-NRR-1248, Special Rept:On 900913,HPCS Piping Triaxial Peak Accelerograph Recorder Could Not Be Calibr.On 900917, Recorder Found Outside Allowable Value.Caused by Damaged Internal Components.Replacement Procured & Calibr22 October 1990Special Rept:On 900913,HPCS Piping Triaxial Peak Accelerograph Recorder Could Not Be Calibr.On 900917, Recorder Found Outside Allowable Value.Caused by Damaged Internal Components.Replacement Procured & CalibrEarthquake
PY-CEI-NRR-1213, Special Rept:On 900807,radiological Effluent Monitoring Instrumentation Inoperable for 72 H.Caused by Default Setpoints.New Microcomputer Chips Installed in All post-accident Radiation Monitors20 August 1990Special Rept:On 900807,radiological Effluent Monitoring Instrumentation Inoperable for 72 H.Caused by Default Setpoints.New Microcomputer Chips Installed in All post-accident Radiation Monitors
PY-CEI-NRR-1209, Special Rept:On 900724,sys Meteorological Monitoring Instrumentation Declared Inoperable.Caused by Faulty Lightning Arresters Attached to Resistance Temp Devices. Faulty Arresters Replaced10 August 1990Special Rept:On 900724,sys Meteorological Monitoring Instrumentation Declared Inoperable.Caused by Faulty Lightning Arresters Attached to Resistance Temp Devices. Faulty Arresters Replaced
PY-CEI-NRR-1061, Special Rept:On 890811,vibration & Loose Parts Monitoring Sys Experienced Spurious Alarms.Caused by Excessive Background Noise.Design Change Request Submitted to Address Hard Line Cable Issue20 September 1989Special Rept:On 890811,vibration & Loose Parts Monitoring Sys Experienced Spurious Alarms.Caused by Excessive Background Noise.Design Change Request Submitted to Address Hard Line Cable Issue
PY-CEI-NRR-0975, Special Rept:On 890112,vibration & Loose Part Monitoring Sys Experienced Series of Spurious Alarms.Caused by Excessive Background Noises.Channel 4 Declared Inoperable on 890122. Channel Will Be Reworked During First Refueling Outage21 February 1989Special Rept:On 890112,vibration & Loose Part Monitoring Sys Experienced Series of Spurious Alarms.Caused by Excessive Background Noises.Channel 4 Declared Inoperable on 890122. Channel Will Be Reworked During First Refueling Outage
PY-CEI-NRR-0915, Special Rept:On 880810,vibration & loose-part Monitoring Sys Experienced Loss of Channel 4 Detection String.Caused by Failure of Preamplifier in Channel 4.Preamplifier Replaced on 88081719 September 1988Special Rept:On 880810,vibration & loose-part Monitoring Sys Experienced Loss of Channel 4 Detection String.Caused by Failure of Preamplifier in Channel 4.Preamplifier Replaced on 880817
PY-CEI-NRR-0902, Special Rept NP-38-04:on 880805,primary Containment Area Gross Radiation Monitors Had Less than Min Required Channels Due to Failed Monitor.Caused by High Voltage Failure Due to Defective Voltage Power Supply Circuit Board.Board Repl19 August 1988Special Rept NP-38-04:on 880805,primary Containment Area Gross Radiation Monitors Had Less than Min Required Channels Due to Failed Monitor.Caused by High Voltage Failure Due to Defective Voltage Power Supply Circuit Board.Board ReplacedGrab sample
PY-CEI-NRR-0844, Special Rept NP-38-03:on 880407,turbine Bldg/Heater Bay Ventilation Exhaust post-accident Monitor (D19) Declared Inoperable.Caused by Electrical Failure on Interface/Relay Boards in Control Room Indication Unit22 April 1988Special Rept NP-38-03:on 880407,turbine Bldg/Heater Bay Ventilation Exhaust post-accident Monitor (D19) Declared Inoperable.Caused by Electrical Failure on Interface/Relay Boards in Control Room Indication Unit
PY-CEI-NRR-0757, Special Rept:On 871116,HPCS Sys Automatically Actuated & Injected to Reactor Vessel Due to Water Level Reaching Level 2.Proper Automatic Response for Feedwater & RCIC Sys Verified8 February 1988Special Rept:On 871116,HPCS Sys Automatically Actuated & Injected to Reactor Vessel Due to Water Level Reaching Level 2.Proper Automatic Response for Feedwater & RCIC Sys Verified
PY-CEI-NRR-0750, Special Rept:On 871015,valid Failure on Div 2 Diesel Generator Occurred During Tech Spec Surveillance 4.8.1.1.2. Caused by Shuttle Valve Failing to Reposition on Start Signal.Valve Replaced & Design Change Initiated13 November 1987Special Rept:On 871015,valid Failure on Div 2 Diesel Generator Occurred During Tech Spec Surveillance 4.8.1.1.2. Caused by Shuttle Valve Failing to Reposition on Start Signal.Valve Replaced & Design Change Initiated
PY-CEI-NRR-0737, Special Rept:On 870923,failure of Div 3 Diesel Generator Occurred While Performing Start & Load Surveillance Test. Caused by Incomplete Investigation Into Maint Run Anomoly Which Failed to Identify Blown Fuse.Fuse Replaced23 October 1987Special Rept:On 870923,failure of Div 3 Diesel Generator Occurred While Performing Start & Load Surveillance Test. Caused by Incomplete Investigation Into Maint Run Anomoly Which Failed to Identify Blown Fuse.Fuse Replaced
PY-CEI-NRR-0729, Special Rept NP-39-01:on 870821,loose Part Detection Sys Declared Inoperable W/Less than Min Required Channels.Caused by Sys Being in Continuous Alarm W/O Confirmation of Loose Parts.Frequency Filters to Be Added30 September 1987Special Rept NP-39-01:on 870821,loose Part Detection Sys Declared Inoperable W/Less than Min Required Channels.Caused by Sys Being in Continuous Alarm W/O Confirmation of Loose Parts.Frequency Filters to Be Added
PY-CEI-NRR-0721, Special Rept NP-38-02:on 870901,accident Monitoring Instrumentation Inoperable on D19 Area Radiation Monitors. Caused by Degraded Insulation Resistance of Field Cable Sys. Action to Restore Channels to Operable Condition Continuing18 September 1987Special Rept NP-38-02:on 870901,accident Monitoring Instrumentation Inoperable on D19 Area Radiation Monitors. Caused by Degraded Insulation Resistance of Field Cable Sys. Action to Restore Channels to Operable Condition ContinuingGrab sample
PY-CEI-NRR-0675, Special Rept NP-38-01:on 870617,post-accident Effluent Radiation Monitors Monthly Surveillance Channel Checks Dicovered Deficient in Meeting Tech Spec Requirements.Caused by Procedural deficiency.D19 Channel Checks Deleted1 July 1987Special Rept NP-38-01:on 870617,post-accident Effluent Radiation Monitors Monthly Surveillance Channel Checks Dicovered Deficient in Meeting Tech Spec Requirements.Caused by Procedural deficiency.D19 Channel Checks DeletedGrab sample
PY-CEI-NRR-0615, Special Rept:On 870227,0311 & 17,valid Test & Failures of Div 1 & 2 Diesel Generators Experienced.Caused by Defective Control Air Solenoid Valve & Faulty Control Air Regulator. Valve & Regulator Replaced.Ler Will Be Submitted by 870327 March 1987Special Rept:On 870227,0311 & 17,valid Test & Failures of Div 1 & 2 Diesel Generators Experienced.Caused by Defective Control Air Solenoid Valve & Faulty Control Air Regulator. Valve & Regulator Replaced.Ler Will Be Submitted by 870327
ML20211P87012 December 1986Special Rept:On 861112,valid Failure of Div 3 Diesel Generator Occurred While Performing Surveillance Tech Spec 4.8.1.1.2.Caused by Indicated Open Circuit in Speed Setting Motor Windings.Speed Setting Motor Replaced
ML20215K69620 October 1986Ro:On 860911,valid Failure of Div 3 Diesel Genarator Occurred While Performing Tech Spec Surveillance 4.8.1.1.2. Caused by Governor Limit Switch Assembly Failing to Properly Set.Switch Replaced
ML20211K82118 June 1986Special Rept:On 860521,valid Failure Occurred on Div 2 Diesel Generator During Performance of Tech Spec Surveillance 4.8.1.1.2.Caused by Failure of Jacket Water Thermostatic Control Valve to Open