Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML23331A29927 November 2023Submittal of Condition Prohibited by Technical Specifications Due to Failure to Sample Diesel Generator Fuel Oil Storage Tank
05000318/LER-2022-001, Forwards LER 2022-001-00 for Calvert Cliffs Nuclear Power Plant, Unit 2, Automatic Reactor Trip Due to High Reactor Coolant System Pressure3 March 2022Forwards LER 2022-001-00 for Calvert Cliffs Nuclear Power Plant, Unit 2, Automatic Reactor Trip Due to High Reactor Coolant System Pressure
ML19169A05913 June 2019Reactor Vessel Level Monitoring System Special Report, Rev. 1Reactor Vessel Water Level
05000318/LER-2017-00119 April 2017Pressurizer Safety Valve As-Found Settings Outside Technical Specification Limits Due To Setpoint Drift
LER 17-001-00 For Calvert Cliffs, Unit 2 re: Pressurizer Safety Valve As-Found Settings Outside Technical Specification Limits Due to Setpoint Drift
Probabilistic Risk Assessment
Significance Determination Process
Large early release frequency
05000318/LER-2016-00124 January 2017Automatic Reactor Trip Due to Main Turbine Electro-Hydraulic Control Fluid Leak
LER 16-001-00 for Calvert Cliffs Nuclear Power Plant, Unit No. 2 Regarding Automatic Reactor Trip Due to Main Turbine Electro-Hydraulic Control Fluid Leak
Anticipated operational occurrence
05000317/LER-2016-00329 July 2016Unit 1 Automatic Trip on Loss of Load due to Spurious Steam Generator High Level Turbine Trip
LER 16-003-00 for Calvert Cliffs Nuclear Power Plant, Unit No. 1 Regarding Automatic Trip on Loss of Load due to Spurious Steam Generator High Level Turbine Trip
Anticipated operational occurrence
05000317/LER-2016-00420 July 2016High Energy Line Break Barrier Breeched Due to Human Performance Error Causing Both Service Water Trains to be Inoperable
LER 16-004-00 for Calvert Cliffs, Unit 1 Regarding High Energy Line Break Barrier Breeched Due to Human Performance Error Causing Both Service Water Trains to be Inoperable
Safe Shutdown
Unanalyzed Condition
05000317/LER-2016-00214 April 2016Pressurizer Safety Relief Nozzle Dissimilar Metal Weld Flaw Exceeded American Society of Mechanical Engineers Code Allowable Limit
LER 16-002-00 for Calvert Cliffs, Unit 1, Regarding Pressurizer Safety Relief Nozzle Dissimilar Metal Weld Flaw Exceeded American Society of Mechanical Engineers Code Allowable Limit
Weld Overlay
Nondestructive Examination
Pressure Boundary Leakage
Dissimilar Metal Weld
DM weld
05000317/LER-2016-00121 March 2016Manual Reactor Trip Due to High Secondary Side Sodium Levels Due to a Condenser Tube Leak
LER 16-001-00 for Calvert Cliffs Nuclear Power Plant Unit 1, Regarding Manual Reactor Trip Due to High Secondary Side Sodium Levels Due to a Condenser Tube Leak
05000318/LER-2015-00127 January 2016Manual Reactor Trip Due to 22 Steam Generator Feed Pump Trip
LER 15-001-00 for Calvert Cliffs, Unit 2, Regarding Manual Reactor Trip Due to Steam Generator Feed Pump 22 Trip
Probabilistic Risk Assessment
Significance Determination Process
Large early release frequency
ML0319504603 July 2003Special Report: National Pollution Discharge Elimination System Permit # MD0002399 Violation