ST-HL-AE-5597, Annual Personnel Exposure Rept

From kanterella
Jump to navigation Jump to search
Annual Personnel Exposure Rept
ML20135D759
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 12/31/1996
From: Logan R
HOUSTON LIGHTING & POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
ST-HL-AE-5597, NUDOCS 9703050478
Download: ML20135D759 (6)


Text

t.

The Light cllouston o mpLighting a nys uth Texas Project Electric Generating

& Power station P. O. Box 289 Wadsworth, Texas 77483 February 27,1997 ST HL-AE-5597 File No. G02 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 South Texas Project Units 1 & 2 Docket Nos. STN 50-498 & 50-499 Annual Reports Required by Technical Specification 6.9.1.2 Attached are the Annual Reports required by the South Texas Project Technical Specification 6.9.1.2. Attachment 1 is the Annual Personnel Exposure Report required by Technical Specification 6.9.1.2.a. Attachment 2 is the annual report required by Technical Specification 6.9.1.2.b of the results of specific activity analyses for any primary coolant samples exceeding Technical Specification 3.4.8 limits.

If you have any questions on this matter, please contact Mr. S. M. Head at (512) 972-7136 or me at (512) 972-7566.

V. gan Manager, Health Physics MKJ/

Attachments: 1) Annual Personnel Exposure Report

2) A Report of Results of Specific Activity Analyses for any Primary h, Cociant Samples Exceeding the Technical Specification 3.4.8

' *"S 050199 _~

9703050478 961231 PDR ADOCK 05000498 R PDR:

,.%. w.,,3{roject Manager on Behalf of the Participants in the South Texas Project

_ ._ . _ _ _ . . . - _ _ - - ~ _ _ _ . _ _ _ _ . _ _ _ _ _ _ . _ - . ._

~

4 Houston Lighting & Power Company ST-HL-AE-5597 South Texas Project Electric Generating Station File No.: G02

Page 2 i

i Leonard J. Callan Rufus S. Scott Regional Administrator, Region IV Associate General Counsel U. S. Nuclear Regulatory Commission Houston Lighting & Power Company 611 Ryan Plaza Drive, Suite 400 P. O. Box 61%7 Arlington, TX 76011-8064 Houston, TX 77208 j Thomas W. Alexion Institute of Nuclear Power Project Manager, Mail Code 13H3 Operations - Records Center U. S, Nuclear Regulatory Commission 700 Galleria Parkway Washington, DC 20555-0001 Atlanta, GA 30339-5957 ,

I David P. Loveless Dr. Bertram Wolfe l Sr. Resident Inspector 15453 Via Vaquero l c/o U. S. Nuclear Regulatory Comm. Monte Sereno, CA 95030 P. O. Box 910 Bay City, TX 77404-0910 Richard A. Ratliff Bureau of Radiation Control J. R. Newman, Esquire Texas Department of Health Morgan, Lewis & Bockius 1100 West 49th Street 1800 M Street, N.W. Austin, TX 78756-3189 Washington, DC 20036-5869 J. R. Egan, Esquire M. T. Hardt/W. C. Gunst Egan & Associates, P.C.

City Public Service 2300 N Street, N.W.

P. O. Box 1771 Washington, D.C. 20037 San Antonio, TX 78296 J. C. Lanier/M. B. Lee U. S. Nuclear Regulatory Commission City of Austin Attention: Document Control Desk Electric Utility Department Washington, D.C. 20555-0001 721 Barton Springs Road  ;

Austin, TX 78704 l Central Power and Light Company J. W. Beck ATTN: G. E. Vaughn/C. A. Johnson Little Harbor Consultants, Inc. l P. O. Box 289, Mail Code: N5012 44 Nichols Road Wadsworth, TX 77483 Cohassett, MA 0^0251166 l l

l

. . j Attachment 1 I ST-HL-AE-5597 i Page 1 of 3 i

ANNUAL PERSONNEL EXPOSURE REPORT J

Technical Specification 6.9.1.2.a requires a tabulation on an annual basis of the number of station, utility, and other personnel (including contractors) receiving exposures greater than 100 mrem /yr according to work and job functions. This data is based on self-reading dosimetry results and is presented on page two of this attachment. Specific tasks  ;

- included in the Special Maintenance work and job function are listed on page three. j

)

i l

l 1

0 4

)

C W kwsp975M $11220 Mas

, ..~ - - - . .- . . -.- . . ~ ._ . . -. - .-. . _ - .

4 Attachment 1 o.. ST-HL-AE-5597

-L 02/26d7 . s.T, 05:00 . Plant Radiation Exposura Planning And Reporting Database Page 2 of 3 Lloennes : HOUST n ~ 0,.ON. LIGHT.ING 29 & POWER COMPANY

, NnC o,,,,.e = ? = " % 60 ^e = otx ^

-PORT - AR 19 6 Po- 1 - i STANDARD FORMAT FOR REPORTING NUMIiER OF PERSONNEL AND MAN-REM BY WORK AND JOB FUNCTION NUMBER OF PERSONNELU 100 MREM) -

TOTAL MAN. REM STATION UrluTY CONTRACTORS STATION UTUTy CONTRACTORS WORK & JOS EMPLOYEES EMPLOYEES AND OTHEnS EMPLOYEES EMPLOYEES AND OTHERS REACTOR OPS & SURVElLANCE OPERATIONS 17 0 0 5 198 0.000 0.000 MAINTENANCE 0 0 0 0 517 0.000 0.046 ENGINEERING 2 0 0 0.805 0.000 0.000 GEN. SUPPORT 20 0 5 1

6.414 0.000 2.234 NUCLEAR A&L 0 0 0 0.509 0 000 0.176 OTHER 0 0 0 0.154 0.000 0.054 ROUTINE MAINTENANCE -

OPERATIONS 0

, 1 0 0.614 0.000 0.000 MAINTENANCE 22 0 4 7.836 0.000 1.830 ENGINEERING 0 0 0 0.310 0.000 0.001 GEN. SUPPORT 6 0 51 1.P71 0.000 14.179

) NUCLEAR A&L 0 0 0 0.133 0.000 0.021 OTHER 0 0 0 0.112 0.000 0.386

' IN-SERVICE INSPECTION

OPERATIONS 1 0 0 0.157 0.000 0.000 MAINTENANCE 7 0 0 1.994 0.000 0.900 ENGINEERING S 0

. 2 0.944 0.000 0.764 GEN. SUPPORT C 0 0 0.215 0.000 0.183 NUCLEAR A&L 0 0 4 0.213 0.000 0.993 I'

OTHER 2 0 0 0 514 0.000 0.001 SPECIAL MAINTENANCE I OPERATIONS 2 0 0 0 656 0.000 0.000 e MAINTENANCE 27 0 4 7.225 0.000 1.376 ENGINEERING 0 0 0 0.139 0.000 0.000

, ' GEN. SUPPORT 10 0 161 2.577 ' O.000 59.949 NUCLEAR A&L 0 1 1 0.247 0.000 0.315 OTHER 0 19 1 0.231 0.000 6 028 CASTE PROCESSING OPERATIONS 4 0 0 1.214 0.000 0.000 MAINTENANCE O 0 0 0.060 0.000 0.000 ENGINEERING 0 0 0 0.071 0.000 0.000 GEN. SUPPORT 6 0 17 2.875 0.000 5.800 NUCLEAR A&L 0 0 0 0.010 0.000 0.000 OTHER 0 s 0 0.003 0.000 0.011 REFUEUNG OPERATIONS 0 0 1 0.252 0 000 0.000 MAINTENANCE 15 0 4 4.909 0 000 1.219 ENGfNEERING 2 0 0 1.037 0.000 0.000 CIN. SUPPORT 4 0 31 1.365 0 000 8.875

, NUCLEAR A&L 0 0 0 0 011 0.000 0 020 OTHER 1 0 11 0 470 c.100 2 402 TLTAL WORK & JOB FUNCTION CPERATONS 26 0 0 s 091 00@ 0.0m MAINTENANCE 71 0 12 22.541 0.000 6.371 ENGPdEERING 7 0 2 3 306 0.000 0.765 GEN. SUPPCHT 46 0 265 15.317 0.000 91.220 NUCLEAR A&L 1 0 5 1.123 0.000 1 525 OTHER 4 0 30 14e4 0.000 e 882 GRAND TOTAL 155 0 314 51.862 0 000 107.763

4' t

Attachment 1 '

ST-HL-AE-5597 Page 3 of 3 1996 Annual Personnel Exposure Report Technical Specification 6.9.1.2 AdditionalInformation

1. The South Texas Project site includes two 1250 Mw, Westinghouse Pressurized i Water Reactors.
2. During 1996, Unit I completed its sixth refueling outage in 22 days.
3. Special maintenance performed in 1996 included the following:

a) Primary inspections on all Unit I steam generators.

b) ' Secondary inspections and sludge lancing on all Unit I steam generators.

c) Templating in preparation for replacement of Unit I steam generators.

d) Reactor coolant pump seal replacement in Unit 1.

e) Reactor coolant pump interferences removed for two pumps to prepare for pump removalin Unit 1.

4. The estimated exposure described in this report is based on electronic dosimeter (Alnor) values.  ;

1 1

ewpwresewape7.sw7 sn xxams

1

. ~

Attachment 2 ST-HL-AE-5597 Page1of1 X

d PRLMARY COOLANT SPECIFIC ACTIVITY REPORT 4

. Technical Specification 6.9.1.2.b requires the results of the specific i activity analyses in which the primary coolant exceeded the limits of Technical .,

j Specification 3.4.8 to be reported on an annual basis. 1 1

Unit 1 and Unit 2 have not exceeded the limits of Technical Specification 3.4.8 for the calendar year of 1996.

J S.WWhehp97-es3597 KM 321MDB