c .

l 3

The Light I c o mp a ny  !

Houston Lighting & Powery.ui h Tnyi rnijnt Ipearly c.cnnating stat;on l'. a nos289 wad.*onto Tnai 77481 March 2, 1992 ST-HL-Ar-4020 File No.: G02 10CFR20.407 1

U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 South Texas Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Annual Reports Required by Tech. Spec. 6.9.1.2 and 10C FR,'O . 4 07 Attached are the Annual Reports required by the South Texas Project Electric Generating Station Technical Specification 6.9.1.2 and 10CFR20.407. These reports consist of: Annual Personnel Exposure Reports required by Technical Specification 6.9.1.2.a and 10CFR20.407; and a report of the results of specific activity analyses in which the primary coolant exceeded the limits of Technical Specification 3.4.0 as recuired by Technical Specification 6.9.1.2.b.

If you should have any questions oc this matter, please contact Mr. C. A. Ayala at (512) 972-8628.

DVLe[ Q-William J. Ju Manager, Nuclear Licensing MKJ/ amp Attachments: 1) Annual Personnel Exposure Reports

2) A Report of Results of Specific Activity Analysis in which the Primary Coolant Exceeded the Limits of Technical Specification 3.4.8 000::17 l

RREP\92056001.182 I A Subsidiary of Ilouston industries incorporated t U 9203090008 911231 '

gDR ADOCK 05000498 f u  ;

Nougon Lighting & Power Company South Texas Project Electric Generating Statu3n ST-HL-AE-4 0 2 0 File No.:G02 Page 2 cc:

Regional Administrator, Region IV Rufus S. Scott Nuclear Regulatory Commission Associate General Counsel 611 Ryan Plaza Drive, Suite 400 Houston Lighting & Power Company Arlington. TX 76011 P. O. Box C1867 Houston, TX 77208 George Dick,: Project Manager-U.S. Nuclear Regulatory Commission INPO Washington, DC 20555 Records Center 1100 Circle 75 Parkway J. I. Tapia Atlanta, GA 30339-3064 Senior Resident Inspector c/o U. S. Nuclear Regulatory Dr. Joseph M. Hendrie Commission 50 Bellport Lane P. O. Box 910 Bellport, NY 11713 Bay City, TX 77414 D. K. Lacker J. R. Newman, Esquire Bureau of Radiation Control Newman & Holtzinger, P.C. Texas Department of Health 1615 L Street, N.W. 1100 West 49th Street Washington, DC 20036 Austin, TX 78756-3189 D. E. Ward /T. M. Puckett Central Power and Light Company P. O. Box 2121 Corpus Christi, TX 78403 J. C. Lanior/M. B. Lee City of Austin Electric Utility Department P.O. Box 1088' Austin, TX 73767-K. J. Fiedler/M. T. Hardt City Public Service Board P.'O. Box 1771 San Antonio, TX 78296 l

l

~

l L Revised 10/11/91 L4/NRC/

l

. Attachment i ST-HL-AE-4020 Page 1 of 5 ANNUAL PERSONNEL EXPOSURE REPOJ1LS Technical Specification 6.9.1.2.a requires a tabulation on an annual basis of the number of station, utility, and other personnel (including contractors) receiving exposures greater than 100 mrem /yr and their associated man-rem exposures according to work and job functions. This data is presented on page two of this attachment. Specific tasks included in the Special Maintenance work and job function are listed on page three.

10CFR20.407(a) requires a rcport of the total number of individuals for whom personnel monitoring was provided for the reporting year. This number and a statistical summary of whole i body exposure to these individuals is presented on page four of this attachment. An explanation of the statistics is provided on page five of this attachment.

During 1991, 2835 personnel were monitored and no single individual roccived greater than 2.0 rem.

IP b

i RREP)92057002.002

_7_..._

02/07/92_AT 12:28 Plant ' Radiation Exposure Planning And Reporting Databue IL A 020 Page 2 of 5 L ic ens'ee: HOUSTON LIGMTING &' POWER COMPANY Gddress;'~ Post Office Box 289

--j ,

Wadsworth, Texas 77483 NRC i ic*nr.e Number (s): NPF --76; NPF - 80 REPORTING YEAR: 1991 APPENDIX A STfiNDARD FORMAT FOR-REPORTING NUMBER OF PERSONNEL AND MON-REM BY WORK AND J0D FUNCTION

, _i' lNUMDER OF PERSONNEL () 100 MREM): TOTAL MAN-REM

  • 1) i g____.______.... .______________;-_-_______________.._____..._________t 8
STATION : UTILITY CONTRACT 0RSt -STATION : UTILITY CONTRACTORS!

l W L JOB FUNCTION l EMFLOYEE'i! EMPLOYCES: AND OTHERS: EMPLOYEES : EMPLOYEEG l AND OTHERSI t

: I  : l

REACiOR OPG & GURVEILLANCE :  : I  !  :  ; l-Maintenance P+rsonnel l 3  ; O 0 1,039 : 0,000 l 0.240 t Operating Personnel 29 l 0 ! 0 t 6.225 l 0,000 1 0,004  :

sics Personnel  : 34 l 0 : 38 11.479 0.000 l 14,790^ !

Maalth Sup+rviso Pty'ry Personnel  ! 5 l 0 0 2,064 1 0.136 1 0.000 1 Engincering Personn31 l 2  ! 0 0  ! 0.665 0,000 0,301  :

hu( J oar f ssurance Personnel: 0 1 0 0 1 0.280  ; 0.000 1 0.000

.0thar Persconel i 0 l- 1 1 0.000 : 1,394 0.652 1'

!  !  !  : l  !

ROUTINE MalNTENANCR l l i  ! l Maintennnce Personnel l 60  ; O  : 16  : 18,975 0.000 6,263 1 0.perating Personnel  :- 1- 1 0 l 0  : 0,224  : 0,000  ! 0.024- 1 Hea hh Pngsics Persore,el  ! 3  ! 0 1  : 1,670 0.000 l 1.954  !

Supervisory Personnel 2  ; o 0  ; 0.833 l 0,149 0.000  :

Engineerind Personnel  : 3 0 1 5  : 1.045 : 0,000 -

1,640 :

Nuclear Assurance Personnel 2  : 0 ; O  : 1.195 : 0.000 1 0.000 i:

Other Personnel  : 0 0  : 43  ! O,000 0,400 l 14,336 i INJ 'RVICf INSPFCTION l  :  : l  !

Maintenance Personn el  ! 1 0 : 0 1 1,364 1 0,000  : 0,461 i-Oper ating Perscnnel - 0 1 0 1 0 0,017 0.000 1 0,00s Health Physics Personnel  : 0  : 0 l 0 1 0,256 ! 0.000 1 0,580 i Supervisory Personnel  : 0  : 0 1 0 1 0,137 : 0,000  : 0.000 :

-Engineering Personnel  : 4 1 0 l 3 1,424 0.000 0.971 :

Nuc lear Assurarce Personnel 2  ! 0 l 0  ! O,942 : 0.000 0,000 :

Oth+r Personnel  : 0 l 0 l 33 0.000 0,195  : 14,818 l l  !  :  :

SPECIAL MAIN 1ENANCE  :  :  :  :

Maintenance Personnel  : 39 l 0 5 12.037 : 0,000 2.289 i Operatarc Personoal .: 0  ! ) i 0  ! O,024 1 0,000  : 0,065 Health Pfigsics Personnel  : 5 0  : 17  ! 1,462  ! O,000 1 5.295 l' Supervisory Personnel l 4  : 0  : 0  : 1,155 0,133 : 0,000 :

Engineering Persornel  : 0 1 0  : 82 l 0,186 : 0.000 38,047  !

Nuclear Assurance Personnel 9  : 0 : 0 l 2,459 : 0,000 l 0.000 Other Personnel  : 0 -l 0 l 59 0.000 1 0,250 1 31,250 l-l I  :  : 1  :

WASTr PROCESSING  :  : i I 1 Maintenance Personnel  : 0 : 0 0  ! O,049 : 0,000 0,013 l Operatind Personnel  : 0 : o  : 0 l- 0.006 0,000 ! 0.000 t Health Physics Personnel .l 4  : l 67  : 3.329 ! 0.000 l 21,236 !

_ Supervisory Personnel  : 1  : 0 -l 0  ! O,787  : 0.059 0.000 :

Engineering Personnel  ! O I- 0 0  ! 0.124  : C.100 l -0,208 -t Nuc lear Assurarce Personnel 0 I O  ! O t -0.073 1 0.000 0.000- l Other Personnel  : 0 l 0 1 1  ! 0.000 ! 0.389 1,859_ l-

i i l- l REFUELING  !  : l l 1  !

Maintenance Persontal  : 25 : 0  : 4 8,310 : 0.000  ! 1,149 ' :

Operating Personnel  : 0 _ 0 l 10  : 0.033. ! 0.000 l- 2.874  :

Health Physics Personnel , a , O l 4 1,396 0.000 1 2.316 Supervisory Personn?1 15 -! 1 0  : 1.907  : 0.213 1 -0.000 1 Engineering Personnel  ; O : 0 15  : 0.217 0.000  : 5.969  :

Nuclear Assurance Personnel 2  ; 0 1 0  : 0,690 ! O,000  ! 0.000 Other Pejrsonnel  : O l 3 40  ! 0.000 ; 0.757 : _10,364  :

l l l l l TOT 01. - WORK & JiOD FUNCT I ON : - ----- ! --- ---- l -------- l ----- l ------- ! - -

Maintenance Parsonnel  : 128 i 0 25 1 4',824 ; 0,000 l 10,4l5  :

Operating Personnel  ; 30 : 0 : 10 1 6,579 : 0,000 l 2.967 1 Health Physics Personnal 49 : 0 l- 127 19,592 ! 0.000- : 46,171 SupervisoF9 Pere,onnel  : 17 1 1 0  : 6,883 0,690 0.000- l Engineering Personnel  ! 9  : O  : 105  ! 3.661 : 0,000 : 47,136 Nuclear Assurance Personnel: 15 l 0 l 0  : 5.639 : 0,000 0.000 ll' Other Personnel  : 0 : 4 1A2  ! 0.000 1 3,385 73,279 l l l l l i l-GRAND TOTAL,  !. 245 : 5  : 449  : 84.178  ; 4,075 179,968  :

..- ......._____ _ _.__.~. . . . - - _ _ _ - - --_ . _ . . _ . . _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _

  • Dose as estimated by Self Reading Dosinctor.

I Attachment-1 ST-ilL-AE-4020 Page 3 of 5 ANNUAL PERSONiiRL EXPOSURE REPORTS additional Information:

The following is a listing of special maintenance, as referenced in the attached Technical Specification 6.1.9.2.a report performed at the South Texas Project Electric Generating Station (STPEGS) for the year 1991:

Chemical Volume Control System (CVCS) valve repairs in both units.

Motor operated valve actuator testing (MOVAT) in both units.

Eddy current testing of steam generator (S/G) tubes in both units.

S/G tube plug removal and installation in both units.

Cold leg shot peening in all four S/Gs in Unit 2.

Sludge lancing of all S/Gs in both units.

Repair of fuel transfer system upender and cart in both units.

Seal replacement on reactor coolant pumps in both units.

Replacement of incore detectors in both units.

Disassembly & inspection of safety injection check valves in both units.

' Installation of alternate 2" RCS vent path in Unit 2.

Modification of the reactor head vent line in Unit 2.

l I'

RREPi92057002.002-l

Atta clunen t 1 I ST-Ilic- AE- 4 0 2 0 l 02/04/92 AT 08:56 Plant Radiation Exposure Planning And PIporting Database 1%ge 4 of 5 PERGONNEL NONITORING - ANNUAL STATISTICAL REPORT FOR 1991 This report is furninhed to the Office of Nuclear Regulatory Research as required by Part 20.407 of the Code of Federal Regulations, Title 10

. Licenseet HOU3 TON l.!CHflNG & POWER COMPANY

! Address: Post Office Box 289 Wadsworth, Texas 77483

]

]NRCLicenseNumber(s)!NPF-76;NPF-80 l*.*.*,...*.**,.*,*,*.**...*.,*.*,***.*..**.**.**..............**....**..*.*...*.....*......

Total nunber of individuals (ce whora personnel monitoring wss reovded for the Reportind Year submitted in accordance with paragraph (a) (2) of Section 20.407 ....................................... 2S35

  • .*.4..n..n*..*n...****..***.***.**.*.********+nn******.on***.***************n*****..*.a.*****

STAT (GrlCAL

SUMMARY

i i

Est imated Whole Body Exposure (1,3) Number of Individuals (rems) in each range / man-rem s

No Measurable Expo <sure(2) ...................................................... 1691 0.018 Measurable Ex ........... .................................. 515 20.448 0 25 1 toto 0 2 6.5 .

.posure less than 0.15 ..................................................,................. 257 43.162 0 .................................................................. 218 77.542 r 0.5 to 0.75 .................................................................... 94 57.398 l

0.75 to 3 ...................................................................... 38 32.247 l -l to 2 .................< ...................................................... 22 25.892 2 to 3 ......................................................................... 0 0.000 3 to 4 ......................................................................... 0 0.000

-4 to 5 ......................................../................................ 0 0.000 5 to 6 ......................................................................... 0 0.000 6 to 7 ......................................................................... 0 0.000 7 to 8 ......................................................................... 0 0.000 ,

8 to 9 ..............................,........................'.................. 0 0.C10 9 to 10 ........................................................................ 0 0.000 10 to 11 ....................................................................... 0 0.000

!! to 12 ....................................................................... 0 0.000 12t .....................................................................r...... 0 0.000

  • * * ** * * * . * * * * * . * * > * *
  • e s * ** * * * * * * *
  • n n * * * *
  • s e e n * * * * * * * * * *
  • w * * * * * * * *
  • n e n e * ** * * *
  • n s e v e n e e * * * * * * * * * * *
1. As determined usig PANASONIC Tt.Ds.

i 2. IncNdes exposure less than 0.010 rers.

I -3. Individual values exactly equal to the value separating ranges shall be reported in the hi dher rang +.

t l

r

TOTAL NUMBER OF INDIVf00ALS IN ALL RANGES
2835 TOTAL MAN-REM 256.707 I

/

APPROVFD DY; i F# DATE: A / O /b

/ yiEAL/H GYSICS MANAGER 4

~

l Completed reports shall be retained for the life cif the plant + 75 years

i k-Attachment i l ST-HL-AE-4020 Page 5 of-5 ANNUAL PERSONNEL EXPOSURE REPORTS The difference in total man-rem recorded on these two reports is due to the use of TLD values on the 10CFR20.407 report and use of SRD values on the Technical Specification 6.9.1.2.a report.

Single individuals are listed in more than one work category on the Technical Specification 6.9.1.2.a report. This accounts for the apparent discrepuncy in the number of individuals with a whole body exposure greater tiG 7 100 mrem on the 10CFR20.407 report.

l e

l l

l -.

RREPiO2037002.002 I

l

--. , - - . . __ . - ~ _ . _ , - _ _ , - . . , . . . _ _

-m.. -

+ Attachment 2 ST-IIL-AE-4020 Page 1 of 1 Technical Specification 6.9.1.2.b requires the results of specific activity analyses in which the primary coolant exceeded the limits of Technical Specification 3.4.8.

Unit 1 and Unit 2 have not exceeded the limits of Technical Specification 3.4.8 for the calendar year of 1991.

RRIP192057002.CC2