RADloAl'r[VE EFFLUENT RFI FASE REPORT 1996 SOUTH TEXAS PROJECT Introduction and Summary INTRODUCTION This Annual Radioactive Effluent Release Report is submitted for the period January 1,1996, through December 31,1996, in accordance with Appendix A of License Nos. NPF-76 and NPF-80, Technical Specifications and the Offsite Dose Calculation Manual.
A single submittal is made for both units combining those sections that are common. Separate tables of releases and release totals are included where separate processing systems exist.
This report includes an annual summary of hourly meteorological measurements taken during each quarter. This data appears as tables of wind direction and wind speed by atmospheric stability class. All assessments of radiation doses are performed in accordance with the Offsite Dose Calculation Manual.
Minimal quantities of radioactivity were released during 1996. Liquid effluents are discharged to the onsite Main Cooling Reservoir and subsequently released offsite. The radioactivity released in liquids beyond the site boundary was estimated using the South Texas Project Electric Generating Station Offsite Dose Calculation Manual. Solid radioactive waste is shipped offsite i
for disposal. The following table is a brief summary of the radioactive effluents and solid waste attributable to the station.
TYPE OF EFFLUENT TYPE DESTINATION VOLUME CUBIC CURIES RADIOACTIVE METER MATERIAL f
NOBLE gas GAS OFFslTE 6.0E+09 3.2E+01 PARTICULA'm AND GAS OFFSITE 6.0E+09 2.0E-04 IODINES TRITIUM GAS OFFsITE 6.0E+09 1.5E+02 TRITIUM LIQUID OFFsITE 4.8E+06
- 2. l E+02 FISSION AND LIQUID OFFSITE 4.8E+06 1.9E-02 ACTIVATION PRODUCTS TRITIUM LIQUID ONSITE 4.9E+G$
1.6E+03 FISSION AND LIQUID ONSITE 4.9E+04 1.lE+00 ACTIVATION PRODUCTS SPENTRESINS AND SOLID FOR BURIAL 4.8E+01' 8.6E+02 FILTERS DRY SOLID FOR BURIAL 1.2E+01 2.5E+00 COMPRESSIBLE WASTE Orginial nported value of 1.5E+0! m' was incorrect, the corrected value is 4.8E+01 m'.
Tritium accounted for the largest fraction of the radioactive effluents both liquid and gaseous.
Tritium was the largest contributor to the offsite doses from radioactive effluents. The offsite doses are well below any regulatory limit and significantly less than the average annual radiation exposure to people in the United States from all sources (360 millirem).
ERRATUM 1 ISSUED March 25,1997 9704010512 970325 PDR ADOCK 05000498 R
s RADIOACrIVE EFFLUEPTT RFI FASE REPORT 1996 SOUTH TEXAS PROJECI Solid Waste and Irradiated Fuel Shipments
/
A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not Irradiated Fuel)
- 1. Type of Waste Units 12-Month 12-Month Est. Total Error, %
Period Shipped Period Buried
- a. Spent resins, filter sludges, m'
4.77E+0l
- 4.77E+0l *
.l.0E+00
+ l.0E+00 evaporator bottoms, etc.
Ci 8.65E+02 8.65E+02 5.0E+01
+ 1.0E+02
- b. Dry compressible waste, m'
2.94E+02 1.16E+01
- 1.0E+00
+ 1.0E+00 contaminated equip., etc.
Ci 1.64E+00 2.46E+00
-6.6E+01
+2.0E+02
- c. Irradiated components, control m'
O.00E+00 0.00E+00 N/A N/A rods, etc.
Ci 0.00E+00 0.00E+00
- d. Other(describe) m' O.00E+00 0.00E+00 N/A N/A Ci 0.00E+00 0.00E+00 0rginial reponed value of 1.47E+01 ni' was incorrect, the corrected value is 4.77E+01 m.
3
- 2. Estimate of major nuclide composition (by type of waste)
- a. Spent resins, filter sludges, evaporator bottoms, etc.
Iron-55 5.63E+01 j
Nickel-63 1.76E+01 Cobalt-60 1.59E+01 Cobalt-58 7.19E+00 l
- b. Dry compressible waste, contaminated equip., etc.
j tron-55 5.38E+01 Cobalt-60 1.26E+01 j
Nickel-63 1.00E+01 Cobalt-58 9.84E+00
- c. N/A N/A N/A 4
- d. N/A N/A N/A
- 3. Solid Waste Disposition:
Number of Shipments Mode of Destination i
Transportation 5
Truck Scientific Ecology Group,Inc.
1560 Bear Creek Road i
Oak Ridge, TN 14 Truck Chem-Nuclear Systems Barnwell Waste Management Facility i
Osborne Road Barnwell, SC
- 4. Class of Solid Waste:
A, B & C
- 5. Type of Containers Used for Shipment:
Stiong Tight, High-integrity Containers, Type A and B casks
- 6. Solidifying Agent:
N/A B. IRRADIATED FUEL SHIPMENTS (Disposal)
No shipments made during this period.